PUF Tubes for Low-volume Sampling
- Designed to meet EPA and ASTM methods for pesticides
and PCBs
- Can be used with personal sample pumps up to 5 L/min
- Precleaned to meet method specifications
- Ready to use
- Suitable for ambient, indoor, or personal air sampling
- Sample up to 24 hours
- Suitable for repacking and recertifying
- Custom PUF/sorbent combinations available
- High-volume PUF Tubes also available
PUF
Tubes for Low-volume Sampling Spec. Sheet (PDF)
Precleaned and Ready to Use
SKC Low-volume PUF Tubes are precleaned to meet or exceed method
specifications for purity and are packaged to allow immediate use
without further treatment. SKC PUF tubes are also reusable. See custom
PUF and repack information.
PUF/Tenax® Multi-bed Tube for Pesticides and PCBs
ASTM Method D4861 and EPA Method TO-10A
Packed with two 30-mm sections of polyurethane foam (PUF) and one
750-mg section of Tenax, this tube is suitable for non-occupational
exposure monitoring of homes, public buildings, and office buildings.
It can simultaneously collect many of the airborne chemicals that
can contribute to "Sick Building Syndrome" as described in ASTM (American
Society of Testing Materials) Method D4861.
Catalog Number 226-124
PUF Tube for Pesticides
EPA Method TO-10A and ASTM Methods D4861 and D4947
Designed for sampling common pesticides including organochlorine,
organophosphorus, pyrethrin, triazine, carbamate, and urea, this
tube contains a single 76-mm PUF plug.
Catalog Number 226-92
PUF/XAD-2® Multi-bed Tube for Pesticides
This tube contains two 30-mm sections of PUF and one 1500-mg section
of XAD-2 sorbent. The method for this tube is under development.
Catalog Number 226-143
PUF Tube with Pre-filter for Dioxins
This PUF-only tube contains a glass fiber pre-filter followed by
a single 76-mm PUF plug. The method for this tube is under development.
Catalog Number 226-126
PUF Tubes for Low-volume Sampling Methods
| Methods |
Compounds |
Sorbent
(Amount) |
Cat. No. |
| ASTM-D4861# |
Organochlorine and organophosphorus pesticides and PCBs |
PUF/Tenax/PUF
(30 mm/750 mg/30 mm) |
|
EPA TO-10A , IP-8
|
Organochlorine and organophosphorus pesticides, carbamate, pyrethrin,
triazine and urea pesticides |
| EPA TO-10A , IP-8 |
Organochlorine and organophosphorus pesticides, carbamate, pyrethrin,
triazine and urea pesticides |
PUF
(76 mm) |
|
| ASTM-D4861# |
Organochlorine and organophosphorus pesticides and PCBs |
| ASTM D4947 |
Chlordane and heptachlor residues |
| Custom |
Pesticides |
PUF/XAD-2/PUF
(30 mm/1500 mg/30 mm) |
|
| Custom |
Dioxins |
Glass Fiber Filter/PUF
(76 mm) |
|
| Accessories |
Cat. No. |
| Tube Holder for Low-volume PUF Tubes |
|
|
| Multi-purpose Calibration Jar |
 |
|
| Large Multi-purpose Calibration Jar, supports
8 in long x 3.25 in diameter devices |
 |
|
| Replacement PUFs/Repacks |
Cat. No. |
| Replacement PUF for 226-92, uncleaned,
76-mm length, pk/20 |
P22692 |
| Repack for 226-92, new PUF
packed into cleaned original glass and inserted into cleaned storage
bottle |
P22692R
|
| Repack for 226-126, new PUF/filter
packed into cleaned original glass and inserted into cleaned storage
bottle |
P226126R |
Repack for 226-143, new PUF/sorbent
packed into cleaned original glass and inserted into cleaned storage
bottle
|
P226143R |
| # |
Use this PUF/Tenax sorbent combination tube for sampling
compounds with high vapor pressure. It also allows the simultaneous
measurement of many airborne chemicals that can contribute
to Sick Building Syndrome (SBS).
|
| |
See the SKC EPA Air Sampling
Guide for a complete list of specific compounds for
each method.
|
| Note: |
PUF tubes used in the Statements of Work
for Superfund sites must be used and analyzed within 14
days of being cleaned. |
| Note: |
EPA methods allow some flexibility accommodating
similar sampling protocols, however, such flexibility places
documentation responsibility on the user. For a detailed
explanation, refer to the methods. |
PUF
Tubes for Low-volume Sampling Spec. Sheet (PDF)
Custom environmental tubes and replacement PUFs are available as well as
PUF tube repacking. Repacking service includes cleaning the glass, packing
it with new sorbent/PUF, and inserting it into a cleaned storage bottle. Contact
SKC at 724-941-9701 for more information.
This page was last modified September 8, 2008
|