Chemical Hazards that begin with D

Chemical Hazard
CAS No.
HSE Method
SKC Equipment
Analytical Method
 1,3- Dichloro-5,5-dimethylhydantion
 118-52-5
     
 2,4- D (ISO)
 94-75-7
See NIOSH 5602 Sorbent Tube  226-58  
 GC-ECD
  Dialkyl 79 phthalate
 83968-18-7
See OSHA 104 Sorbent Tube  226-56 
 GC-FID
  Diallyl phthalate
 131-17-9
See OSHA CSI Sorbent Tube  226-30-16  
 GC-FID
  Diatomaceous earth (natural respirable dust)
 
14/3 IOM Particulate Sampler  225-70A  
FOAM 225-772 or
Cyclone  225-69  
Filter  225-58F  
 GR
  Dibenzoyl peroxide
 94-36-0
See NIOSH 5009 Preloaded Filter Cassette  225-3-01 
 HPLC-UV
  Dibismuth tritelluride
 1304-82-1
91 IOM Particulate Sampler  225-70A  
Filter  225-19  
 XRF
  Diboron trioxide
 1303-86-2
14/3 IOM Particulate Sampler  225-70A  
FOAM 225-772 or
Cyclone  225-69  
Filter  225-58F  
 GR
 1,2- Dibromoethane
 106-93-4
96 Sorbent Tube  226-01  
 GC-ECD
 1,2- Dibromoethane
 106-93-4
88 Passive Sampler  575-001  
 GC-FID
  Dibutyl hydrogen phosphate
 107-66-4
See NIOSH 5017 Filter  225-17-01  
Filter Cassette  225-2LF  
Filter Cassette and Cyclone Holder  225-1  
 GC-FPD
  Dibutyl phthalate
 84-74-2
32 Sorbent Tube  226-35  
 GC-FID
 2,2- Dichloro-4,4'-methylene dianiline (MbOCA)
 101-14-4
75 IOM Particulate Sampler  225-70A  
Filter  225-58F  
 HPLC
 2,2'- Dichloro-4,4'-methylene dianiline (MbOCA)
 101-14-4
75 Coated Filter in Preloaded Cassette  225-9004  
Filter Cassette and Cyclone Holder  225-1  
 GC-ECD
  Dichloroacetylene
 7572-29-4
See OSHA CSI Sorbent Tube  226-01  
 GC-FID
 1,2- Dichlorobenzene (ortho-dichlorobenzene)
 95-50-1
96 Sorbent Tube  226-01  
 GC-FID
 1,2- Dichlorobenzene (ortho-dichlorobenzene)
 95-50-1
88 Passive Sampler  575-001  
 GC-FID
 1,4- Dichlorobenzene (para-dichlorobenzene)
 106-46-7
96 Sorbent Tube  226-01  
 GC-FID
 1,4- Dichlorobenzene (para-dichlorobenzene)
 106-46-7
88 Passive Sampler  575-001  
 GC-FID
 1,1- Dichloroethane
 75-34-3
96 Sorbent Tube  226-01  
 GC-FID
 1,2- Dichloroethane (ethylene dichloride)
 107-06-2
88 Passive Sampler  575-001  
 GC-FID
 1,2- Dichloroethane (ethylene dichloride)
 107-06-2
72, 80 Sorbent Tube  226-358  
 GC-ECD
 1,2- Dichloroethane (ethylene dichloride)
 107-06-2
96 Sorbent Tube  226-01  
 GC-FID
 1,2- Dichloroethylene cis:trans isomers 60:40
 540-59-0
96 Sorbent Tube  226-01  
 GC-FID
 1,2- Dichloroethylene cis:trans isomers 60:40
 540-59-0
88 Passive Sampler  575-001  
 GC-FID
  Dichlorofluoromethane
 75-43-4
96 Sorbent Tube  226-01  
 GC-FID
  Dichloromethane
 75-09-2
96 Sorbent Tube  226-01  
 GC-FID
  Dichloromethane
 75-09-2
72, 80 Sorbent Tube  226-358  
 GC-ECD
  Dichloromethane
 75-09-2
88 Passive Sampler  575-001  
 GC-FID
  Dicylohexyl phthalate
 84-61-7
32 Sorbent Tube  226-35  
 GC-FID
  Dicylopentadiene
 77-73-6
88 Passive Sampler  575-001  
 GC-FID
  Diethyl ether
 60-29-7
88 Passive Sampler  575-001  
 GC-FID
  Diethyl ether
 60-29-7
96 Sorbent Tube  226-01  
 GC-FID
  Diethyl phthalate
 84-66-2
32 Sorbent Tube  226-35  
 GC-FID
  Diethyl sulphate
 64-67-5
89 Sorbent Tube  226-357  
 GC-MS
  Diethylamine
 109-89-7
96 Sorbent Tube  226-10  
 GC-FID
  Dihydrogen selenide (as Se)
 7783-07-5
See OSHA CSI Impinger  225-36-2  
Impinger  225-36-5  
Impinger Trap  225-22  
 AA
  Diisobutyl phthalate
 84-69-5
32 Sorbent Tube  226-35  
 GC-FID
  Diisodecyl phthalate
 26761-40-0
32 Sorbent Tube  226-35  
 GC-FID
  Diisononyl phthalate
 28553-12-0
32 Sorbent Tube  226-35  
 GC-FID
  Diisooctyl phthalate
 27554-26-3
32 Sorbent Tube  226-35  
 GC-FID
  Diisopropyl ether
 108-20-3
96 Sorbent Tube  226-01  
 GC-FID
  Diisopropyl ether
 108-20-3
88 Passive Sampler  575-001  
 GC-FID
  Diisopropylamine
 108-18-9
See OSHA CSI Impinger  225-36-2  
Impinger Trap  225-22  
 GC-ECD
  Dimethoxymethane
 109-87-5
96 Sorbent Tube  226-01  
 GC-FID
  Dimethoxymethane
 109-87-5
88 Passive Sampler  575-001  
 GC-FID
  Dimethyl ether
 115-10-6
  Detector Tube  810-161 
 CLR
  Dimethyl phthalate
 131-11-3
See OSHA 104 Sorbent Tube  226-56  
 GC-FID
  Dimethyl sulphate
 77-78-1
96 Sorbent Tube  226-114  
 GC-ECN
  Dimethyl sulphate
 77-78-1
89 Sorbent Tube  226-357  
 GC-MS
  Dimethylamine
 124-40-3
96 Sorbent Tube  226-10  
 GC-FID
 2- Dimethylaminoethanol
 108-01-0
See OSHA CSI Sorbent Tube  226-10-04  
 GC-FID
  Dimethylformamide
 68-12-2
88 Passive Sampler  575-002  
 GC-FID
 2,6- Dimethylheptan-4-one
 108-83-8
88 Passive Sampler  575-002  
 GC-FID
 2,6- Dimethylheptan-4-one
 108-83-8
96 Sorbent Tube  226-01  
 GC-FID
  Dinitrobenzene (all isomers)
 25154-54-5
See OSHA CSI Sorbent Tube  226-30-16  
 HPLC-UV
  Dinonyl phthalate
 84-76-4
32 Sorbent Tube  226-35  
 GC-FID
 1,4- Dioxane
 123-91-1
96 Sorbent Tube  226-01  
 GC-FID
 1,4- Dioxane
 123-91-1
88 Passive Sampler  575-002  
 GC-FID
  Diphenyl ether (vapour)
 101-84-8
96 Sorbent Tube  226-35-01  
 GC-FID
  Diphenyl ether (vapour)
 101-84-8
88 Passive Sampler  575-001  
 GC-FID
  Diphenylamine
 122-39-4
See OSHA 78 Coated Filter in Preloaded Cassette  225-9004  
Filter Cassette and Cyclone Holder  225-1  
 HPLC-UV
  Diphosphorus pentasulphide
 1314-80-3
See OSHA ID-128SG Preloaded Filter Cassette  225-802  
Filter Cassette and Cyclone Holder  225-1  
 IC
  Diphosphorus pentoxide
 1314-56-3
See OSHA ID-111 Preloaded Filter Cassette  225-3-01 
Filter Cassette and Cyclone Holder  225-1  
 IC
  Dipropylene glycol methyl ether
 34590-94-8
72 Sorbent Tube  226-357  
Sorbent Tube  226-358  
 GC-ECD
  Dipropylene glycol methyl ether
 34590-94-8
88 Passive Sampler  575-002  
 GC-FID
  Diquat dibromide (ISO)
 85-00-7
See OSHA CSI IOM Particulate Sampler  225-70A  
Filter  225-58F  
 HPLC/UV
  Disodium disulphite
 7681-57-4
See OSHA ID-121 Preloaded Filter Cassette  225-3-01  
Filter Cassette and Cyclone Holder  225-1  
 AA or AES
  Disodium tetraborate (anhydrous)
 1330-43-4
See OSHA ID-125G Preloaded Filter Cassette  225-3-01 or
Preloaded Filter Cassette  225-3100 
Filter Cassette and Cyclone Holder  225-1  
 ICP-AES
  Disodium tetraborate (decahydrate)
 1303-96-4
See OSHA ID-125G Preloaded Filter Cassette  225-3-01 or
Preloaded Filter Cassette  225-3100 
Filter Cassette and Cyclone Holder  225-1  
 ICP-AES
  Disodium tetraborate (pentahydrate)
 12179-04-3
See OSHA ID-125G Preloaded Filter Cassette  225-3-01 or
Preloaded Filter Cassette  225-3100 
Filter Cassette and Cyclone Holder  225-1  
 ICP-AES
  Disulphur dichloride
 10025-67-9
See OSHA CSI Impinger  225-36-2  
Impinger Trap  225-22  
 CLR
 6,6'- Di-tert-butyl-4,4'-thiodi-m-cresol
 96-69-5
See OSHA CSI Preloaded Filter Cassette  225-706 or
Cyclone  225-69-35 
Filter  225-7 
 HPLC-UV
 2,6- Di-tert-butyl-p-cresol
 128-37-0
See OSHA PV2108 Sorbent Tube  226-57  
 GC-FID
  Diuron (ISO)
 330-54-1
See NIOSH 5601 Sorbent Tube  226-58 or
Sorbent Tube  226-30-16  
 HPLC-UV
  Dusts (Inhalable)
 
14/3 IOM Particulate Sampler  225-70A  
Filter  225-58F  
 GR
  Dusts (Respirable)
 
14/3 IOM Particulate Sampler  225-70A  
Filter  225-58F 
FOAM 225-772 or
Cyclone  225-69 
Filter  225-58F 
 GR
 N,N- Dimethylacetamide
 127-19-5
96 Sorbent Tube  226-10  
 GC-FID
 N,N- Dimethylaniline
 121-69-7
96 Sorbent Tube  226-10  
 GC-FID
 N,N- Dimethylaniline
 121-69-7
88 Passive Sampler  575-001  
 GC-FID
 N,N- Dimethylethylamine
 598-56-1
See OSHA PV2096 Sorbent Tube  226-18 
 GC-NPD

Chemical Hazards by First Letter

A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z
Chemical Hazard Search:  
  Enter chemical name in box above

Method Number Search:
  Enter method number in box above

Catalog Number Search:
  Enter the exact SKC Catalog number in box above

CAS Number Search:  
  Enter CAS no. in box above

 


This SKC Air Sampling Guide is a reference only to assist users in finding the method, sampling equipment, and sampling media for a specific compound. This publication is intended for general information only and should not be used as a substitute for reviewing applicable government regulations, equipment operating instructions, or legal standards. Users must consult the appropriate sampling method for the compound of interest before sampling. The sampling parameters shown here are suggestions based on the ranges or volume, flow, and time specified in the methods. It is the responsibility of the analyst performing the sampling and analysis steps to adjust the parameters so that the required detection limits can be obtained. The information contained in this document should not be construed as legal advice or opinion nor as a final authority on legal or regulatory procedures.

  About SKC Terms of Use Privacy Policy Contact Us Site Map Ordering Information
This site was last modified June 19, 2013
SKC Inc.'s Quality Policy is in Compliance with IS0 9001-2008
© Copyright 1995-2013 SKC Inc.