Chemical Hazards that begin with A

Chemical CASNO
Method
CFF
Sampling Equipment
Analytical Method
Abietic acid 514-10-3    OSHA CSI   Preloaded Filter Cassette  225-709  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
HPLC-UV — High-performance Liquid Chromatography With UV Detector
Absidia species (fungi, molds, spores)     OSHA CSI   BioStage  225-9611  
Pump 228-9530
Varies — Analytical Method is dependant upon the nature of the sample. Refer to the method for details
Absidia species (fungi, molds, spores)     OSHA CSI   Preloaded Filter Cassette  225-3-01  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
Varies — Analytical Method is dependant upon the nature of the sample. Refer to the method for details
Acenaphthene (polynuclear aromatic hydrocarbons by GC-MS) 83-32-9    ASTM D 6209   PUF Tube  226-131  
Filter  225-1821  
GC-MS — Gas Chromatography -Mass Spectroscopy
Acenaphthene (polynuclear aromatic hydrocarbons by GC) 83-32-9    NIOSH 5515   Preloaded Filter Cassette  225-1713  
Sorbent Tube  226-30-04  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
GC-FID — Gas Chromatography-Flame Ionization Detector
Acenaphthene (polynuclear aromatic hydrocarbons by HPLC) 83-32-9    NIOSH 5506   Preloaded Filter Cassette  225-1713  
Sorbent Tube  226-30-04  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
HPLC-UV — High-performance Liquid Chromatography With UV Detector
Acenaphthylene (polynuclear aromatic hydrocarbons by HPLC) 208-96-8    NIOSH 5506   Preloaded Filter Cassette  225-1713  
Sorbent Tube  226-30-04  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
HPLC-UV — High-performance Liquid Chromatography With UV Detector
Acenaphthylene (polynuclear aromatic hydrocarbons by GC) 208-96-8    NIOSH 5515   Preloaded Filter Cassette  225-1713  
Sorbent Tube  226-30-04  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
GC-FID — Gas Chromatography-Flame Ionization Detector
Acenaphthylene (polynuclear aromatic hydrocarbons by GC-MS) 208-96-8    ASTM D 6209   PUF Tube  226-131  
Filter  225-1821  
GC-MS — Gas Chromatography -Mass Spectroscopy
Acetaldehyde 75-07-0    NIOSH 2538   Sorbent Tube  226-27  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector
Acetaldehyde 75-07-0    NIOSH 3507   Impinger  225-36-2  
Impinger Trap  225-22  
Pump 210-1002MH
HPLC — High-performance Liquid Chromatography
Acetaldehyde 75-07-0    1007   Sorbent Tube  226-27  
Pump 210-1002MH
GC-NPD — Gas Chromatography-Nitrogen-Phosphorus Detector
Acetaldehyde (aldehydes, screening) 75-07-0    NIOSH 2539   Sorbent Tube  226-118  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector, GC-MS — Gas Chromatography -Mass Spectroscopy
Acetaldehyde (see Passive Sampling Guide) 75-07-0      Detector Tube  810-91D or
Detector Tube  810-152D or
Detector Tube  810-151D  
 
Acetaldehyde 75-07-0    ASTM D 5197   Sorbent Tube  226-120 or
Sorbent Tube  226-119  
Pump 210-5001
HPLC-UV — High-performance Liquid Chromatography With UV Detector
Acetamide 60-35-3      Sorbent Tube  226-10  
Pump 210-1002MH
GC-NPD — Gas Chromatography-Nitrogen-Phosphorus Detector
Acetates (screening)     NIOSH 2549   Sorbent Tube  226-330  
Pump 210-1002MH
GC-MS — Gas Chromatography -Mass Spectroscopy
Acetic acid 64-19-7    NIOSH 1603   Sorbent Tube  226-01  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector
Acetic acid (see Passive Sampling Guide) 64-19-7      Passive Sampler  575-001  
 
Acetic acid (see Passive Sampling Guide) 64-19-7      Detector Tube  800-01071 or
Detector Tube  810-81D  
 
Acetic acid 64-19-7      Sorbent Tube  226-01  
Pump 210-1002MH
IC or GC-FID — Ion Chromatography or GC-FID Gas Chromatography-Flame Ionization Detector
Acetic acid 64-19-7      Sorbent Tube  226-01  
Pump 210-1002MH
IC or GC-FID — Ion Chromatography or GC-FID Gas Chromatography-Flame Ionization Detector
Acetic anhydride 108-24-7    1392   Coated Filter in Preloaded Cassette  225-9010  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
GC-NPD — Gas Chromatography-Nitrogen-Phosphorus Detector
Acetic anhydride 108-24-7    1391   Coated Filter in Preloaded Cassette  225-9009  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-1002MH
GC-NPD — Gas Chromatography-Nitrogen-Phosphorus Detector
Acetic anhydride 108-24-7    NIOSH 3506   Impinger  225-36-2  
Impinger Trap  225-22  
Pump 210-5001
VAS — Visible Absorption Spectrophotometry
Acetic anhydride (see Passive Sampling Guide) 108-24-7      Detector Tube  810-81D  
 
Acetoin (Acetyl methyl carbinol) 513-86-0      Sorbent Tube  226-183  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector
Acetoin (Acetyl methyl carbinol) 513-86-0      Sorbent Tube  226-183  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector
Acetoin 513-86-0    NIOSH 2558   Sorbent Tube  not available from SKC  
GC-FID — Gas Chromatography-Flame Ionization Detector
Acetone 67-64-1      Sorbent Tube  not available from SKC  
GC-FID — Gas Chromatography-Flame Ionization Detector
Acetone (see Passive Sampling Guide) 67-64-1      Passive Sampler  575-002  
 
Acetone (see Passive Sampling Guide) 67-64-1      Detector Tube  810-151D or
Detector Tube  810-152D  
 
Acetone 67-64-1    ASTM D 5197   Sorbent Tube  226-120 or
Sorbent Tube  226-119  
Pump 210-5001
HPLC-UV — High-performance Liquid Chromatography With UV Detector
Acetone (ketones I) 67-64-1    NIOSH 1300   Sorbent Tube  226-01  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector
Acetone (ketones I) 67-64-1    NIOSH 2555   Sorbent Tube  not available from SKC  
GC-FID — Gas Chromatography-Flame Ionization Detector
Acetonitrile 75-05-8    NIOSH 1606   Sorbent Tube  226-09  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector
Acetonitrile (see Passive Sampling Guide) 75-05-8      Passive Sampler  575-002  
 
Acetophenone 98-86-2      Sorbent Tube  226-35  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector
2-Acetylaminofluorene 53-96-3    OSHA CSI   Preloaded Filter Cassette  225-706  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
HPLC-UV — High-performance Liquid Chromatography With UV Detector
Acetylene 74-86-2    OSHA CSI   Detector Tube  810-171  
DET TB — Color-Indicating Detector Tube or Diffusion Tubes
Acetylene tetrabromide (1,1,2,2-tetrabromoethane) 79-27-6    NIOSH 2003   Sorbent Tube  226-10  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector
Acetylene tetrabromide 79-27-6    OSHA CSI   Sorbent Tube  226-10  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector
Acetyl methyl carbinol (acetoin) 513-86-0    NIOSH 2558   Sorbent Tube  not available from SKC  
GC-FID — Gas Chromatography-Flame Ionization Detector
Acetylsalicylic acid 50-78-2    OSHA CSI   Preloaded Filter Cassette  225-709  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
HPLC-UV — High-performance Liquid Chromatography With UV Detector
Acid/base (skin)       Patch  769-3006 or
Wipe  769-1036 or
Test Kit  769-1006  
CI — Colorimetric
Acid/base (surface)       Wipe  769-1024 or
Test Kit  769-1006  
CI — Colorimetric
Acid black 128 37293-45-1    OSHA CSI   Preloaded Filter Cassette  225-706  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
HPLC-UV — High-performance Liquid Chromatography With UV Detector
Acid blue 9 2650-18-2    OSHA CSI   Preloaded Filter Cassette  225-706  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
HPLC-UV — High-performance Liquid Chromatography With UV Detector
Acid orange 74 10127-27-2    OSHA CSI   Preloaded Filter Cassette  225-706  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
HPLC-UV — High-performance Liquid Chromatography With UV Detector
Acid red 114 6459-94-5    OSHA CSI   Preloaded Filter Cassette  225-709  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
HPLC-UV — High-performance Liquid Chromatography With UV Detector
Acids, inorganic (see specific compounds)     NIOSH 7903 1016   Sorbent Tube  226-10-03  
Pump 210-1002MH
IC — Ion Chromatography
Acid yellow 34 6359-90-6    OSHA CSI   Preloaded Filter Cassette  225-706  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
HPLC-UV — High-performance Liquid Chromatography With UV Detector
Acid yellow 42 6375-55-9    OSHA CSI   Preloaded Filter Cassette  225-706  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
HPLC-FD — High-performance Liquid Chromatography With Fluorescence Detector
Acremonium species (fungi, molds, spores)     OSHA CSI   Preloaded Filter Cassette  225-3-01  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
Varies — Analytical Method is dependant upon the nature of the sample. Refer to the method for details
Acremonium species (fungi, molds, spores)     OSHA CSI   BioStage  225-9611  
Pump 228-9530
Varies — Analytical Method is dependant upon the nature of the sample. Refer to the method for details
Acridine 260-94-6    1077   Filter  225-7  
Filter Cassette  225-2LF  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
GR — Gravimetric Analysis and HPLC-FD — High-performance Liquid Chromatography With Fluorescence Detector or GR — Gravimetric Analysis and HPLC-UV — High-performance Liquid Chromatography With UV Detector
Acrolein (aldehydes, screening) 107-02-8    NIOSH 2539   Sorbent Tube  226-118  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector, GC-MS — Gas Chromatography -Mass Spectroscopy
Acrolein 107-02-8      Sorbent Tube  226-117  
Pump 210-1002MH
GC-NPD — Gas Chromatography-Nitrogen-Phosphorus Detector
Acrolein 107-02-8    NIOSH 2501   Sorbent Tube  226-118  
Pump 210-1002MH
GC-NPD — Gas Chromatography-Nitrogen-Phosphorus Detector
Acrylamide 79-06-1      Sorbent Tube  226-10  
Filter  225-16  
Filter Cassette  225-32  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
GC-NPD — Gas Chromatography-Nitrogen-Phosphorus Detector
Acrylic acid 79-10-7    NON 10   Sorbent Tube  226-70A  
Pump 210-1002MH
GC — Gas Chromatography
Acrylic acid 79-10-7      Sorbent Tube  226-30-08  
Pump 210-1002MH
HPLC-UV — High-performance Liquid Chromatography With UV Detector
Acrylonitrile 107-13-1    NIOSH 1604 1266   Sorbent Tube  226-01  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector
Acrylonitrile (see Passive Sampling Guide) 107-13-1      Passive Sampler  575-002  
 
Acrylonitrile 107-13-1    1265   Sorbent Tube  226-01  
Pump 210-5001
GC-NPD — Gas Chromatography-Nitrogen-Phosphorus Detector
Actinomycetes, thermophilic     NIOSH 0800   BioStage  225-9611  
Pump 228-9530
Varies — Analytical Method is dependant upon the nature of the sample. Refer to the method for details
Adipic acid 124-04-9    OSHA CSI   Sorbent Tube  226-30-16  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector
Adiponitrile 111-69-3    OSHA CSI   Sorbent Tube  226-01  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector
Aerobic bacteria (by GC-FAME)     NIOSH 0801   BioStage  225-9611  
Pump 228-9530
GC-FID — Gas Chromatography-Flame Ionization Detector
Alcohols (screening)     NIOSH 2549   Sorbent Tube  226-330  
Pump 210-1002MH
GC-MS — Gas Chromatography -Mass Spectroscopy
Alcohols combined     NIOSH 1405   Sorbent Tube  226-01  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector
Alcohols I (see specific compounds)     NIOSH 1400   Sorbent Tube  226-01  
GC-FID — Gas Chromatography-Flame Ionization Detector
Alcohols II (see specific compounds)     NIOSH 1401   Sorbent Tube  226-01  
GC-FID — Gas Chromatography-Flame Ionization Detector
Alcohols III (see specific compounds)     NIOSH 1402   Sorbent Tube  226-01  
GC-FID — Gas Chromatography-Flame Ionization Detector
Alcohols IV (see specific alcohol)     NIOSH 1403   Sorbent Tube  226-01  
GC-FID — Gas Chromatography-Flame Ionization Detector
Aldehydes (screening)     NIOSH 2539   Sorbent Tube  226-118  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector, GC-MS — Gas Chromatography -Mass Spectroscopy
Aldehydes (screening)     NIOSH 2549   Sorbent Tube  226-330  
Pump 210-1002MH
GC-MS — Gas Chromatography -Mass Spectroscopy
Aldehydes (see Environmental Sampling Guide)        
 
Aldehydes (see Passive Sampling Guide)       Passive Sampler  500-400  
HPLC-UV — High-performance Liquid Chromatography With UV Detector
Aldicarb (Temik) 116-06-3    1399   Sorbent Tube  226-30-16  
Pump 210-5001
GC-NPD — Gas Chromatography-Nitrogen-Phosphorus Detector
Aldicarb (organonitrogen pesticides) 116-06-03    NIOSH 5601   Sorbent Tube  226-58 or
Sorbent Tube  226-30-16  
Pump 210-5001
HPLC-UV — High-performance Liquid Chromatography With UV Detector
Aldrin 309-00-2    ASTM D 4861   PUF Tube  226-92  
Pump 210-5001
GC-ECD — Gas Chromatography-Electron Capture Detector
Aldrin 309-00-2    NIOSH 5502   Preloaded Filter Cassette  225-709  
Impinger  225-36-2  
Impinger Trap  225-22  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
GC-ECN — Gas Chromatography-Electrolytic Conductivity Detector
Aldrin 309-00-2    OSHA CSI   Preloaded Filter Cassette  225-709  
Impinger  225-36-2  
Impinger Trap  225-22  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
GC-ECN — Gas Chromatography-Electrolytic Conductivity Detector
Aliphatic hydrocarbons (screening)     NIOSH 2549   Sorbent Tube  226-330  
Pump 210-1002MH
GC-MS — Gas Chromatography -Mass Spectroscopy
Alkaline dusts     NIOSH 7401   Filter  225-17-01  
Filter Cassette  225-3LF  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
TITRA — Titration
Allethrin 584-79-2    ASTM D 4861   PUF Tube  226-92  
Pump 210-5001
HPLC-UV — High-performance Liquid Chromatography With UV Detector
Allyl alcohol (alcohols combined) 107-18-6    NIOSH 1405   Sorbent Tube  226-01  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector
Allyl alcohol 107-18-6      Sorbent Tube  226-01  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector
Allyl alcohol (see Passive Sampling Guide) 107-18-6      Passive Sampler  575-002  
 
Allyl alcohol 107-18-6    OSHA CSI   Sorbent Tube  226-01  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector
Allyl alcohol (alcohols III) 107-18-6    NIOSH 1402   Sorbent Tube  226-01  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector
Allyl chloride (see Passive Sampling Guide) 107-5-1      Passive Sampler  575-001  
 
Allyl chloride 107-5-1    1126   Sorbent Tube  226-01  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector
Allyl chloride 107-5-1    NIOSH 1000   Sorbent Tube  226-01  
Pump 210-5001
GC-FID — Gas Chromatography-Flame Ionization Detector
Allyl glycidyl ether 106-92-3    NIOSH 2545   Sorbent Tube  226-35-03  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector
Allyll amine (see Passive Sampling Guide) 107-11-9      Passive Sampler  500-400  
HPLC-UV — High-performance Liquid Chromatography With UV Detector
Allyl propyl disulfide 2179-59-1      Sorbent Tube  226-110  
Pump 210-1002MH
GC-FPD — Gas Chromatography-Flame Photometricdetector
Alternaria species (fungi, molds, spores)     OSHA CSI   Preloaded Filter Cassette  225-3-01  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
Varies — Analytical Method is dependant upon the nature of the sample. Refer to the method for details
Alternaria species (fungi, molds, spores)     OSHA CSI   BioStage  225-9611  
Pump 228-9530
Varies — Analytical Method is dependant upon the nature of the sample. Refer to the method for details
alpha-Alumina (respirable fraction) 1344-28-1    OSHA CSI   Cyclone  225-105  
Filter  225-8-01  
Filter Cassette  225-3LF  
Filter Cassette and Cyclone Holder  225-1  
GR — Gravimetric Analysis
Alumina (particulates, respirable) 1344-28-1    NIOSH 0600 1038   Cyclone  225-01-02  
Filter Cassette and Cyclone Holder  225-1  
Filter  225-8-01  
Filter Cassette  225-3LF  
Pump 210-5001
GR — Gravimetric Analysis
alpha-Alumina (total dust) 1344-28-1    OSHA CSI   Filter  225-8-01  
Filter Cassette and Cyclone Holder  225-1  
Filter Cassette  225-2LF  
Pump 210-5001
GR — Gravimetric Analysis
Alumina (particulates, total) 1344-28-1    NIOSH 0500 1035   Filter  225-8-01  
Filter Cassette and Cyclone Holder  225-1  
Filter Cassette  225-2LF  
Pump 210-5001
GR — Gravimetric Analysis
Alumina (aluminum & compounds [total dust as Al]) 1344-28-1    NIOSH 7013   Preloaded Filter Cassette  225-3-01  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
AA-F — Atomic Absorption-Flame
Aluminum (elements by ICP HNO3/HClO4 ashing) 7429-90-5    NIOSH 7300 1455   Preloaded Filter Cassette  225-3-01  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
ICP-AES — Inductively Coupled Plasma-Atomic Emission Spectroscopy
Aluminum (elements by ICP HNO3 digestion) 7429-90-5    NIOSH 7303   Preloaded Filter Cassette  225-3-01  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
ICP-AES — Inductively Coupled Plasma-Atomic Emission Spectroscopy
Aluminum (elements by ICP Aqua Regia ashing) 7429-90-5    NIOSH 7301   Preloaded Filter Cassette  225-3-01 or
Preloaded Filter Cassette  225-803  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
ICP-AES — Inductively Coupled Plasma-Atomic Emission Spectroscopy
Aluminum, pyro powders 7429-90-5    OSHA CSI   Filter  225-8-01  
Filter Cassette and Cyclone Holder  225-1  
Filter Cassette  225-2LF  
Pump 210-5001
GR — Gravimetric Analysis
Aluminum (respirable fraction) 7429-90-5    OSHA CSI   Filter  225-8-01  
Cyclone  225-105  
Filter Cassette  225-3LF  
Filter Cassette and Cyclone Holder  225-1  
GR — Gravimetric Analysis
Aluminum soluble salts 7429-90-5      Preloaded Filter Cassette  225-3-01  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
AA — Atomic Absorption Spectroscopy or AES Atomic Emission Spectroscopy
Aluminum (total dust) 7429-90-5    OSHA CSI   Filter  225-8-01  
Filter Cassette and Cyclone Holder  225-1  
Filter Cassette  225-2LF  
Pump 210-5001
GR — Gravimetric Analysis
Aluminum & compounds (total dust as Al) 7429-90-5    NIOSH 7013   Preloaded Filter Cassette  225-3-01  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
AA-F — Atomic Absorption-Flame
Aluminum welding fumes 7429-90-5    OSHA CSI   Filter  225-8-01  
Filter Cassette and Cyclone Holder  225-1  
Filter Cassette  225-2LF  
Pump 210-5001
GR — Gravimetric Analysis
Alupent 5874-97-5    OSHA CSI   Preloaded Filter Cassette  225-709  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
HPLC-UV — High-performance Liquid Chromatography With UV Detector
Amiben 133-90-4    OSHA CSI   Preloaded Filter Cassette  225-709  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
HPLC-UV — High-performance Liquid Chromatography With UV Detector
Amines     NIOSH 2002   Sorbent Tube  226-10  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector or Gas Chromatography-Nitrogen Specific Detector
Amines, aliphatic     NIOSH 2010   Sorbent Tube  226-10  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector
Amines, aliphatic (skin)       Patch  769-3005 or
Wipe  769-1035 or
Test Kit  769-1005  
CI — Colorimetric
Amines, aliphatic (surface)       Wipe  769-1025 or
Test Kit  769-1005  
CI — Colorimetric
Amines, aromatic (skin)       Patch  769-3001 or
Wipe  769-1031 or
Test Kit  769-1001  
CI — Colorimetric
Amines, aromatic (surface)       Wipe  769-1021 or
Test Kit  769-1001  
CI — Colorimetric
2-Amino-2-methy-1-propanol 124-68-5    OSHA CSI   Sorbent Tube  226-10  
Pump 210-1002MH
GC-NPD — Gas Chromatography-Nitrogen-Phosphorus Detector
2-Amino-2-methy-1-propanol 124-68-5      Sorbent Tube  226-30-16  
Pump 210-1002MH
HPLC-UV — High-performance Liquid Chromatography With UV Detector
4-Aminobiphenyl 92-67-1    1233   Coated Filter in Preloaded Cassette  225-9004  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
GC-ECD — Gas Chromatography-Electron Capture Detector
2-Aminoethanol 141-43-5    NIOSH 2007   Sorbent Tube  226-10-04  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector
2-Aminoethanol 141-43-5    NIOSH 3509   Impinger  225-36-1  
Impinger Trap  225-22  
Pump 210-5001
IC — Ion Chromatography
2-Aminoethanol 141-43-5      Sorbent Tube  226-30-18  
Pump 210-1002MH
HPLC-UV — High-performance Liquid Chromatography With UV Detector
Aminoethanol compounds I (see specific compounds)     NIOSH 2007   Sorbent Tube  226-10-04  
GC-FID — Gas Chromatography-Flame Ionization Detector
Aminoethanol compounds II (see specific compounds)     NIOSH 3509   Impinger  225-36-1  
Impinger Trap  225-22  
Pump 210-5001
IC — Ion Chromatography
Aminoethylethanolamine 111-41-1      Sorbent Tube  226-30-18  
Pump 210-1002MH
HPLC-UV — High-performance Liquid Chromatography With UV Detector
N-Aminoethylpiperazine 140-31-8    OSHA CSI   Sorbent Tube  226-98  
Pump 210-1002MH
GC-NPD — Gas Chromatography-Nitrogen-Phosphorus Detector
p-Aminophenylarsonic acid (arsenic, organo-) 98-50-0    NIOSH 5022   Filter  225-17-01  
Filter Cassette  225-3LF  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
IC-AA — Ion Chromatography With Atomic Absorption Spectrophotometer Detector
2-Aminopyridine 504-29-0      Coated Filter in Preloaded Cassette  225-9004  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
GC-NPD — Gas Chromatography-Nitrogen-Phosphorus Detector
3-Aminopyridine 462-08-8      Coated Filter in Preloaded Cassette  225-9004  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
GC-NPD — Gas Chromatography-Nitrogen-Phosphorus Detector
4-Aminopyridine 504-24-5      Coated Filter in Preloaded Cassette  225-9004  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
GC-NPD — Gas Chromatography-Nitrogen-Phosphorus Detector
2-Aminopyridine 504-29-0    OSHA CSI   Sorbent Tube  226-35-02  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector
Amitrole 61-82-5      Impinger  225-36-1  
Impinger Trap  225-22  
Pump 210-5001
HPLC-UV — High-performance Liquid Chromatography With UV Detector
Ammonia 7664-41-7    NIOSH 6015   Sorbent Tube  226-10-06  
Preloaded Filter Cassette  225-3-01  
Pump 210-1002MH
VAS — Visible Absorption Spectrophotometry
Ammonia 7664-41-7    NON 41   Sorbent Tube  226-61  
Pump 210-5001
CLR — Spectrophotometric Method or Colorimeter
Ammonia 7664-41-7    1008   Sorbent Tube  226-29  
Pump 210-5001
IC-ECN — Ion Chromatography/Electrolytic Conductivity Detector
Ammonia (by IC) 7664-41-7    NIOSH 6016   Sorbent Tube  226-10-06  
Preloaded Filter Cassette  225-3-01  
Pump 210-1002MH
IC — Ion Chromatography
Ammonia (see Passive Sampling Guide) 7664-41-7      Detector Tube  800-01301 or
Detector Tube  810-3DL or
Detector Tube  810-3D  
 
Ammonium chloride (fume) 12125-02-9      Preloaded Filter Cassette  225-3-01  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
IC-ECN — Ion Chromatography/Electrolytic Conductivity Detector
Ammonium hydroxide (see ammonia) 7664-41-7       
 
Ammonium metavanadate (see vanadium oxides) 7803-55-6    NIOSH 7504    
 
Ammonium nitrate 6484-52-2    OSHA CSI   Filter  225-8-01  
Filter Cassette and Cyclone Holder  225-1  
Filter Cassette  225-2LF  
Pump 210-5001
GR — Gravimetric Analysis
Ammonium sulfamate (respirable dust) 7773-06-0    OSHA CSI   Cyclone  225-105  
Filter Cassette and Cyclone Holder  225-1  
Filter  225-8-01  
Filter Cassette  225-3LF  
GR — Gravimetric Analysis
Ammonium sulfamate (total dust) 7773-06-0    OSHA CSI   Filter  225-8-01  
Filter Cassette and Cyclone Holder  225-1  
Filter Cassette  225-2LF  
Pump 210-5001
GR — Gravimetric Analysis
Ammonium sulfamate (total dust) 7773-06-0      Preloaded Filter Cassette  225-3-01  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
GR — Gravimetric Analysis and IC-ECN — Ion Chromatography-Electrolytic Conductivity Detector
n-Amyl acetate 628-63-7      Sorbent Tube  226-01  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector
sec-Amyl acetate (2-pentyl acetate) 626-38-0      Sorbent Tube  226-01  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector
sec-Amyl acetate (2-pentyl acetate) (see Passive Sampling Guide) 626-38-0      Passive Sampler  575-001  
 
n-Amyl acetate (esters I) 628-63-7    NIOSH 1450   Sorbent Tube  226-01  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector
n-Amyl acetate (see Passive Sampling Guide) 628-63-7      Passive Sampler  575-001 or
Passive Sampler  575-002  
 
n-Amyl alcohol (see Passive Sampling Guide) 71-41-0      Passive Sampler  575-002  
GC-FID — Gas Chromatography-Flame Ionization Detector
t-Amyl methyl ether (methyl tert-amyl ether) (see Passive Sampling Guide) 994-05-8      Passive Sampler  575-001  
GC-FID — Gas Chromatography-Flame Ionization Detector
Amyl nitrite 463-07-0    OSHA CSI   Sorbent Tube  226-01  
Pump 210-1002MH
HPLC-UV — High-performance Liquid Chromatography With UV Detector
Aniline 62-53-3    NIOSH 2017   Coated Filter in Preloaded Cassette  225-9004  
Sorbent Tube  226-15  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector
Aniline 62-53-3      Sorbent Tube  226-98  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector
Aniline (amines, aromatic) 62-53-3    NIOSH 2002 1058   Sorbent Tube  226-10  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector or Gas Chromatography-Nitrogen Specific Detector
o-Anisaldehyde 135-02-4    OSHA CSI   Sorbent Tube  226-30  
Pump 210-1002MH
HPLC-UV — High-performance Liquid Chromatography With UV Detector
Anisidine 29191-52-4    NIOSH 2514   Sorbent Tube  226-30-05  
Pump 210-5001
HPLC-UV — High-performance Liquid Chromatography With UV Detector
Anisidine (o- & p-isomers) 29191-52-4    OSHA CSI   Sorbent Tube  226-30-05  
Pump 210-5001
HPLC-UV — High-performance Liquid Chromatography With UV Detector
Anthophyllite fibers (see asbestos fibers) 77536-67-5    NIOSH 7400    
 
Anthracene 120-12-7    1075   Filter  225-7  
Filter Cassette  225-2LF  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
GR — Gravimetric Analysis and HPLC-FD — High-performance Liquid Chromatography With Fluorescence Detector or GR — Gravimetric Analysis and HPLC-UV — High-performance Liquid Chromatography With UV Detector
Anthracene (polynuclear aromatic hydrocarbons by GC-MS) 120-12-7    ASTM D 6209   PUF Tube  226-131  
Filter  225-1821  
GC-MS — Gas Chromatography -Mass Spectroscopy
Anthracene (polynuclear aromatic hydrocarbons by GC) 120-12-7    NIOSH 5515   Preloaded Filter Cassette  225-1713  
Sorbent Tube  226-30-04  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
GC-FID — Gas Chromatography-Flame Ionization Detector
Anthracene (polynuclear aromatic hydrocarbons by HPLC) 120-12-7    NIOSH 5506   Preloaded Filter Cassette  225-1713  
Sorbent Tube  226-30-04  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
HPLC-UV — High-performance Liquid Chromatography With UV Detector
Antimony (elements by ICP HNO3/HClO4 ashing) 7440-36-0    NIOSH 7300 1455   Preloaded Filter Cassette  225-3-01  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
ICP-AES — Inductively Coupled Plasma-Atomic Emission Spectroscopy
Antimony & compounds (as Sb) 7440-36-0      Preloaded Filter Cassette  225-3-01  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
AA — Atomic Absorption Spectroscopy or AES Atomic Emission Spectroscopy
Antimony & compounds (as Sb) 7440-36-0      Preloaded Filter Cassette  225-3-01 or
Preloaded Filter Cassette  225-3100  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
ICP-AES — Inductively Coupled Plasma-Atomic Emission Spectroscopy
Antimony (elements by ICP Aqua Regia ashing) 7440-36-0    NIOSH 7301   Preloaded Filter Cassette  225-3-01 or
Preloaded Filter Cassette  225-803  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
ICP-AES — Inductively Coupled Plasma-Atomic Emission Spectroscopy
Antimony (elements by ICP HNO3 digestion) 7440-36-0    NIOSH 7303   Preloaded Filter Cassette  225-3-01  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
ICP-AES — Inductively Coupled Plasma-Atomic Emission Spectroscopy
Antimony (ICP analysis of metal/metalloid particulates from solder operations) 7440-36-0      Preloaded Filter Cassette  225-3-01  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
ICP-AES — Inductively Coupled Plasma-Atomic Emission Spectroscopy
ANTU (alphanaphthyl thiourea) 86-88-4    OSHA CSI   Filter  225-17-01  
Filter Cassette  225-2LF  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
HPLC-UV — High-performance Liquid Chromatography With UV Detector
Apron 57837-19-1      Preloaded Filter Cassette  225-709  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
HPLC-UV — High-performance Liquid Chromatography With UV Detector
Aqua fortis (acids, inorganic) 7697-37-2    NIOSH 7903 1016   Sorbent Tube  226-10-03  
Pump 210-1002MH
IC — Ion Chromatography
Aroclor 15972-60-8    ASTM D 4861   PUF Tube  226-92  
Pump 210-5001
GC-ECD — Gas Chromatography-Electron Capture Detector
Aroclor 15972-60-8    NIOSH 5602   Sorbent Tube  226-58  
Pump 210-5001
GC-ECD — Gas Chromatography-Electron Capture Detector
Aroclor 1242 53469-21-9    ASTM D 4861   PUF Tube  226-92  
Pump 210-5001
GC-ECD — Gas Chromatography-Electron Capture Detector
Aroclor 1242 (42% Cl) (see polychlorobiphenyls) 53469-21-9    NIOSH 5503    
 
Aroclor 1254 53469-21-9    ASTM D 4861   PUF Tube  226-92  
Pump 210-5001
GC-ECD — Gas Chromatography-Electron Capture Detector
Aroclor 1254 (54% Cl) (see polychlorobiphenyls) 11097-69-1    NIOSH 5503    
 
Aroclor 1260 11096-82-5    ASTM D 4861   PUF Tube  226-92  
Pump 210-5001
GC-ECD — Gas Chromatography-Electron Capture Detector
Aromatic hydrocarbons (screening)     NIOSH 2549   Sorbent Tube  226-330  
Pump 210-1002MH
GC-MS — Gas Chromatography -Mass Spectroscopy
Arsenic (inorganic compounds as As) 7440-38-2      Preloaded Filter Cassette  225-3-01  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
AAs-HGA — Atomic Absorption Spectroscopy-High Temperature Graphite Atomizer
Arsenic, inorganic (volatile compounds as As) 7440-38-2      Coated Filter in Preloaded Cassette  225-9001  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
AAs-HGA — Atomic Absorption Spectroscopy-High Temperature Graphite Atomizer
Arsenic (elements on wipes) 7440-38-2    NIOSH 9102   Wipe  225-2414  
Template  225-2403 or
Template  225-2415  
ICP-AES — Inductively Coupled Plasma-Atomic Emission Spectroscopy
Arsenic (elements by ICP HNO3 digestion) 7440-38-2    NIOSH 7303   Preloaded Filter Cassette  225-3-01  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
ICP-AES — Inductively Coupled Plasma-Atomic Emission Spectroscopy
Arsenic (elements by ICP Aqua Regia ashing) 7440-38-2    NIOSH 7301   Preloaded Filter Cassette  225-3-01 or
Preloaded Filter Cassette  225-803  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
ICP-AES — Inductively Coupled Plasma-Atomic Emission Spectroscopy
Arsenic (elements by ICP HNO3/HClO4 ashing) 7440-38-2    NIOSH 7300 1040   Preloaded Filter Cassette  225-3-01  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
ICP-AES — Inductively Coupled Plasma-Atomic Emission Spectroscopy
Arsenic & compounds (as As) 7440-38-2    NIOSH 7900   Preloaded Filter Cassette  225-3-01  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
AA-F — Atomic Absorption-Flame
Arsenic, organo- 7440-38-2    NIOSH 5022   Filter  225-17-01  
Filter Cassette  225-2LF  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
IC-AA — Ion Chromatography With Atomic Absorption Spectrophotometer Detector
Arsenic trioxide as AS 1327-53-3    NIOSH 7901   Filter  225-5  
Filter Cassette  225-2LF  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
AsA-GF — Atomic Absorption Spectroscopy-Graphite Furnace
Arsine 7784-42-1    NIOSH 6001 1278   Sorbent Tube  226-01  
Pump 210-1002MH
AsA-GF — Atomic Absorption Spectroscopy-Graphite Furnace
Arylam (see carbaryl) 63-25-2       
 
Asbestos 1332-21-4    1301   Filter Cassette with Cowl  225-321 or
Filter Cassette with Cowl  225-326 or
Filter Cassette with Cowl  225-321A or
Filter Cassette with Cowl  225-327  
Pump 210-5001
PCM — Phase Contrast Microscopy
Asbestos (by TEM) 1332-21-4    NIOSH 7402   Filter Cassette with Cowl  225-327  
Pump 210-5001
TEM — Transmission Electron Microscopy
Asbestos ((bulk) by PLM) 1332-21-4    NIOSH 9002    
P LM — Polarized Light Microscopy
Asbestos (chrysotile) 12001-29-5    NIOSH 9000    
XRD — X-Ray Diffraction
Asbestos fibers 1332-21-4    NIOSH 7400 1033   Filter Cassette with Cowl  225-321 or
Filter Cassette with Cowl  225-326 or
Filter Cassette with Cowl  225-321A or
Filter Cassette with Cowl  225-327  
PCM — Phase Contrast Microscopy
Asbestos (mass concentrations) 1332-21-4    ASTM D 5756 1440   Micro Vacuum Cassette  225-322  
Pump 210-5001
TEM — Transmission Electron Microscopy
Asbestos (structure number concentrations) 1332-21-4    ASTM D 5755 1440   Micro Vacuum Cassette  225-322  
Pump 210-5001
TEM — Transmission Electron Microscopy
Aspartame 22839-47-0    NIOSH 5031   Filter  225-17-01  
Filter Cassette  225-2LF  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
HPLC-UV — High-performance Liquid Chromatography With UV Detector
Aspergillus flavipes species (fungi, molds, spores)     OSHA CSI   Preloaded Filter Cassette  225-3-01  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
Varies — Analytical Method is dependant upon the nature of the sample. Refer to the method for details
Aspergillus flavipes species (fungi, molds, spores)     OSHA CSI   BioStage  225-9611  
Pump 228-9530
Varies — Analytical Method is dependant upon the nature of the sample. Refer to the method for details
Aspergillus flavus species (fungi, molds, spores)     OSHA CSI   Preloaded Filter Cassette  225-3-01  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
Varies — Analytical Method is dependant upon the nature of the sample. Refer to the method for details
Aspergillus flavus species (fungi, molds, spores)     OSHA CSI   BioStage  225-9611  
Pump 228-9530
Varies — Analytical Method is dependant upon the nature of the sample. Refer to the method for details
Aspergillus fumigatus species (fungi, molds, spores)     OSHA CSI   BioStage  225-9611  
Pump 228-9530
Varies — Analytical Method is dependant upon the nature of the sample. Refer to the method for details
Aspergillus fumigatus species (fungi, molds, spores)     OSHA CSI   Preloaded Filter Cassette  225-3-01  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
Varies — Analytical Method is dependant upon the nature of the sample. Refer to the method for details
Aspergillus glaucus species (fungi, molds, spores)     OSHA CSI   BioStage  225-9611  
Pump 228-9530
Varies — Analytical Method is dependant upon the nature of the sample. Refer to the method for details
Aspergillus glaucus species (fungi, molds, spores)     OSHA CSI   Preloaded Filter Cassette  225-3-01  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
Varies — Analytical Method is dependant upon the nature of the sample. Refer to the method for details
Aspergillus nidulans species (fungi, molds, spores)     OSHA CSI   BioStage  225-9611  
Pump 228-9530
Varies — Analytical Method is dependant upon the nature of the sample. Refer to the method for details
Aspergillus nidulans species (fungi, molds, spores)     OSHA CSI   Preloaded Filter Cassette  225-3-01  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
Varies — Analytical Method is dependant upon the nature of the sample. Refer to the method for details
Aspergillus niger species (fungi, molds, spores)     OSHA CSI   BioStage  225-9611  
Pump 228-9530
Varies — Analytical Method is dependant upon the nature of the sample. Refer to the method for details
Aspergillus niger species (fungi, molds, spores)     OSHA CSI   Preloaded Filter Cassette  225-3-01  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
Varies — Analytical Method is dependant upon the nature of the sample. Refer to the method for details
Aspergillus ochraceus (fungi, molds, spores)     OSHA CSI   BioStage  225-9611  
Pump 228-9530
Varies — Analytical Method is dependant upon the nature of the sample. Refer to the method for details
Aspergillus ochraceus (fungi, molds, spores)     OSHA CSI   Preloaded Filter Cassette  225-3-01  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
Varies — Analytical Method is dependant upon the nature of the sample. Refer to the method for details
Aspergillus versicolor (fungi, molds, spores)     OSHA CSI   BioStage  225-9611  
Pump 228-9530
Varies — Analytical Method is dependant upon the nature of the sample. Refer to the method for details
Aspergillus versicolor (fungi, molds, spores)     OSHA CSI   Preloaded Filter Cassette  225-3-01  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
Varies — Analytical Method is dependant upon the nature of the sample. Refer to the method for details
Asphalt fume (benzene-soluble & total particulate) 8052-42-4    NIOSH 5042   Filter  225-27-07  
Support Pads  225-27  
Filter Cassette  225-2LF  
Pump 210-5001
GR — Gravimetric Analysis
Asphalt fume particulate     ASTM D 6494   Preloaded Filter Cassette  225-1713  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
GR — Gravimetric Analysis
Asphalt fumes (petroleum) 8052-42-4    1078   Filter  225-7  
Filter Cassette  225-2LF  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
GR — Gravimetric Analysis and HPLC-FD — High-performance Liquid Chromatography With Fluorescence Detector or GR — Gravimetric Analysis and HPLC-UV — High-performance Liquid Chromatography With UV Detector
Atrazine 1912-24-9    ASTM D 4861   PUF Tube  226-92  
Pump 210-5001
GC-NPD — Gas Chromatography-Nitrogen-Phosphorus Detector
Atrazine 1912-24-9    NIOSH 5602   Sorbent Tube  226-58  
Pump 210-5001
GC-ECD — Gas Chromatography-Electron Capture Detector
Atrazine 1912-24-9    OSHA CSI   Preloaded Filter Cassette  225-706  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
HPLC-UV — High-performance Liquid Chromatography With UV Detector
Auramine 492-80-8    OSHA CSI   Preloaded Filter Cassette  225-709  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
HPLC-UV — High-performance Liquid Chromatography With UV Detector
Aureobasidium pullulans (fungi, molds, spores)     OSHA CSI   BioStage  225-9611  
Pump 228-9530
Varies — Analytical Method is dependant upon the nature of the sample. Refer to the method for details
Aureobasidium pullulans (fungi, molds, spores)     OSHA CSI   Preloaded Filter Cassette  225-3-01  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
Varies — Analytical Method is dependant upon the nature of the sample. Refer to the method for details
Aureobasidium species (fungi, molds, spores)     OSHA CSI   BioStage  225-9611  
Pump 228-9530
Varies — Analytical Method is dependant upon the nature of the sample. Refer to the method for details
Aureobasidium species (fungi, molds, spores)     OSHA CSI   Preloaded Filter Cassette  225-3-01  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
Varies — Analytical Method is dependant upon the nature of the sample. Refer to the method for details
Azelaic acid 123-99-9    NIOSH 5019   Preloaded Filter Cassette  225-803  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
GC-FID — Gas Chromatography-Flame Ionization Detector
Azinphos-ethyl 2642-71-9    OSHA CSI   Sorbent Tube  226-30-16  
Pump 210-5001
GC-FPD — Gas Chromatography-Flame Photometricdetector
Azinphos-methyl 86-50-0      Sorbent Tube  226-30-16  
Pump 210-5001
GC-FPD — Gas Chromatography-Flame Photometricdetector
Azinphos-methyl (organophosphorus pesticides) 86-50-0    NIOSH 5600   Sorbent Tube  226-58  
Pump 210-5001
GC-FPD — Gas Chromatography-Flame Photometricdetector
1,1'-Azobisformamide 123-77-3    OSHA CSI   Sorbent Tube  226-30-16  
Pump 210-5001
HPLC-UV — High-performance Liquid Chromatography With UV Detector

Chemical Hazards by First Letter

A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z

 

Chemical Hazard Search:  
  Enter chemical name in box above

CAS No. Search:  
  Enter CAS number in box above

Method Number Search:  
  Enter method number in box above

Catalog Number Search:  
  Enter the exact SKC catalog number in the box


This SKC Air Sampling Guide is a reference only to assist users in finding the method, sampling equipment, and sampling media for a specific compound. This publication is intended for general information only and should not be used as a substitute for reviewing applicable government regulations, equipment operating instructions, or legal standards. Users must consult the appropriate sampling method for the compound of interest before sampling. The sampling parameters shown here are suggestions based on the ranges or volume, flow, and time specified in the methods. It is the responsibility of the analyst performing the sampling and analysis steps to adjust the parameters so that the required detection limits can be obtained. The information contained in this document should not be construed as legal advice or opinion nor as a final authority on legal or regulatory procedures.

  About SKC Terms of Use Privacy Policy Contact Us Site Map Ordering Information
This site was last modified May 20, 2013
SKC Inc.'s Quality Policy is in Compliance with IS0 9001-2008
© Copyright 1995-2013 SKC Inc.