| Chemical |
CASNO |
Method |
CFF |
Sampling Equipment |
Analytical Method |
| 2,4-D (2,4-dichlorophenoxyacetic acid) |
94-75-7 |
NIOSH 5001
|
|
Preloaded Filter Cassette 225-706 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| 2,4-D (2,4-dichlorophenoxyacetic acid) |
94-75-7 |
OSHA CSI
|
|
Preloaded Filter Cassette 225-709 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| 2,4-D (2-butoxyethyl ester) |
1928-43-4 |
NIOSH 5602
|
|
Sorbent Tube 226-58 Pump 210-5001
|
GC-ECD — Gas Chromatography-Electron Capture Detector
|
| 2,4-D (2-butoxyethyl ester) |
1929-73-3 |
NIOSH 5602
|
|
Sorbent Tube 226-58 Pump 210-5001
|
GC-ECD — Gas Chromatography-Electron Capture Detector
|
| D & C red #19 |
81-88-9 |
OSHA CSI
|
|
Preloaded Filter Cassette 225-709 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| 2,4-D acid |
94-75-7 |
NIOSH 5602
|
|
Sorbent Tube 226-58 Pump 210-5001
|
GC-ECD — Gas Chromatography-Electron Capture Detector
|
| Dacthal |
1861-32-1 |
ASTM D 4861
|
|
PUF Tube 226-92 Pump 210-5001
|
GC-ECD — Gas Chromatography-Electron Capture Detector
|
| DAP (diallyl phthalate) |
131-17-9 |
OSHA CSI
|
|
Sorbent Tube 226-30-16 Pump 210-5001
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| 2,4-D, BE |
1929-73-3 |
NIOSH 5602
|
|
Sorbent Tube 226-58 Pump 210-5001
|
GC-ECD — Gas Chromatography-Electron Capture Detector
|
| DBP (see dibutyl phthalate) |
84-74-2 |
|
|
|
|
| p,p-DDE |
72-55-9 |
ASTM D 4861
|
|
PUF Tube 226-92 Pump 210-5001
|
GC-ECD — Gas Chromatography-Electron Capture Detector
|
| p,p-DDT |
50-29-3 |
ASTM D 4861
|
|
PUF Tube 226-92 Pump 210-5001
|
GC-ECD — Gas Chromatography-Electron Capture Detector
|
| DDT |
50-29-3 |
OSHA CSI
|
|
Preloaded Filter Cassette 225-709 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
GC-ECD — Gas Chromatography-Electron Capture Detector
|
| DDVP (dichlorvos) |
62-73-7 |
ASTM D 4861
|
|
PUF Tube 226-92 Pump 210-5001
|
GC-ECD — Gas Chromatography-Electron Capture Detector
|
| Decaborane |
17702-41-9 |
OSHA CSI
|
|
Preloaded Filter Cassette 225-3-01 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
ICP — Inductively Coupled Plasma
|
| Decabromodiphenyl oxide |
1163-19-5 |
NIOSH 2559
|
|
Filter 225-1822 Support Pads 225-27 Filter Cassette 225-2LF Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Decabromodiphenyl oxide |
1163-19-5 |
OSHA CSI
|
|
Preloaded Filter Cassette 225-709 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
GC-ECD — Gas Chromatography-Electron Capture Detector
|
| n-Decane (hydrocarbons, BP 36 to 216 C) |
124-18-5 |
NIOSH 1500
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| n-Decane (see Passive Sampling Guide) |
124-18-5 |
|
|
Passive Sampler 575-001 or Passive Sampler 575-002
|
|
| Decyl alcohol |
112-30-1 |
OSHA CSI
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Decyl alcohol (see Passive Sampling Guide) |
112-30-1 |
|
|
Passive Sampler 575-001
|
|
| 2,4-D, EH |
1928-43-4 |
NIOSH 5602
|
|
Sorbent Tube 226-58 Pump 210-5001
|
GC-ECD — Gas Chromatography-Electron Capture Detector
|
| DEHP (see di-2-ethylhexyl phthalate) |
117-81-7 |
|
|
|
|
| Dehydroabietic acid |
1740-19-3 |
OSHA CSI
|
|
Preloaded Filter Cassette 225-709 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Dehydroisoandrosterone |
53-43-0 |
OSHA CSI
|
|
Preloaded Filter Cassette 225-709 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Demeton |
8065-48-3 |
NIOSH 5514
|
|
Filter 225-5 Screen 225-26 Filter Cassette 225-2LF Sorbent Tube 226-30-05 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
GC-FPD — Gas Chromatography-Flame Photometricdetector
|
| Demeton (Systox) |
8065-48-3 |
OSHA CSI
|
|
Sorbent Tube 226-30-16 Pump 210-5001
|
GC-FPD — Gas Chromatography-Flame Photometricdetector
|
| Demosan |
2675-77-6 |
OSHA CSI
|
|
Preloaded Filter Cassette 225-709 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
GC-ECD — Gas Chromatography-Electron Capture Detector
|
| DEP (see diethyl phthalate) |
84-66-2 |
|
|
|
|
| Desflurane |
57041-67-5 |
|
1760
|
Sorbent Tube 226-81A Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Desflurane (see Passive Sampling Guide) |
57041-67-5 |
|
|
Passive Sampler 575-002
|
|
| Di-(2-ethylhexyl) adipate |
103-23-1 |
OSHA CSI
|
|
Filter 225-17-04 Filter Cassette 225-3LF Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Di-(2-ethylhexyl) phthalate |
117-81-7 |
OSHA CSI
|
|
Sorbent Tube 226-30-16 Pump 210-5001
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Di-(2-ethylhexyl) phthalate (DEHP) |
117-81-7 |
NIOSH 5020
|
|
Preloaded Filter Cassette 225-3-01 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Diacetone alcohol |
123-42-2 |
|
1123
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Diacetone alcohol (see Passive Sampling Guide) |
123-42-2 |
|
|
Passive Sampler 575-002
|
|
| Diacetone alcohol (alcohols combined) |
123-42-2 |
NIOSH 1405
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Diacetone alcohol (alcohols III) |
123-42-2 |
NIOSH 1402
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Diacetyl |
431-03-8 |
NIOSH 2557
|
|
Sorbent Tube not available from SKC
|
GC — Gas Chromatography
|
| Diacetyl |
431-03-8 |
|
|
Sorbent Tube 226-183 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Diacetyl |
431-03-8 |
|
|
Sorbent Tube 226-183 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Diallyl disulfide |
2179-57-9 |
|
|
Sorbent Tube 226-110 Pump 210-1002MH
|
GC-FPD — Gas Chromatography-Flame Photometricdetector
|
| Diallyl phthalate |
131-17-9 |
OSHA CSI
|
|
Sorbent Tube 226-30-16 Pump 210-5001
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| 1,2-Diaminoethane |
107-15-3 |
NIOSH 2540
|
|
Sorbent Tube 226-30-18 Pump 210-1002MH
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| o-Dianisidine |
119-90-4 |
|
1235
|
Coated Filter in Preloaded Cassette 225-9004 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
GC-ECD — Gas Chromatography-Electron Capture Detector
|
| o-Dianisidine-based dyes |
119-90-4 |
OSHA CSI
|
|
Filter 225-17-04 Filter Cassette 225-3LF Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| o-Dianisidine dyes (dyes, benzidine) |
2429-71-2 |
NIOSH 5013
|
|
Filter 225-17A Filter Cassette 225-3LF Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Diazinon (organophosphorus pesticides) |
333-41-5 |
NIOSH 5600
|
|
Sorbent Tube 226-58 Pump 210-5001
|
GC-FPD — Gas Chromatography-Flame Photometricdetector
|
| Diazinon |
333-41-5 |
|
1396
|
Sorbent Tube 226-30-16 Pump 210-5001
|
GC-FPD — Gas Chromatography-Flame Photometricdetector
|
| Diazinon |
333-41-5 |
ASTM D 4861
|
|
PUF Tube 226-92 Pump 210-5001
|
GC-NPD — Gas Chromatography-Nitrogen-Phosphorus Detector
|
| Diazomethane |
334-88-3 |
NIOSH 2515
|
|
Sorbent Tube 226-23 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Diazomethane |
334-88-3 |
OSHA CSI
|
|
Sorbent Tube 226-23 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dibenz(a,h)anthracene |
53-70-3 |
OSHA CSI
|
|
Preloaded Filter Cassette 225-709 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Dibenz(a,h)anthracene (polynuclear aromatic hydrocarbons by GC) |
53-70-3 |
NIOSH 5515
|
|
Preloaded Filter Cassette 225-1713 Sorbent Tube 226-30-04 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dibenz(a,h)anthracene (polynuclear aromatic hydrocarbons by HPLC) |
53-70-3 |
NIOSH 5506
|
|
Preloaded Filter Cassette 225-1713 Sorbent Tube 226-30-04 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC-FD — High-performance Liquid Chromatography With Fluorescence Detector
|
| Dibenz(a,h)anthracene (polynuclear aromatic hydrocarbons by GC-MS) |
53-70-3 |
ASTM D 6209
|
|
PUF Tube 226-131 Filter 225-1821
|
GC-MS — Gas Chromatography -Mass Spectroscopy
|
| Diborane |
19287-45-7 |
NIOSH 6006
|
|
Sorbent Tube 226-151 Filter not available from SKC and Filter Cassette 225-32 Pump 210-5001
|
PES — Plasma Emission Spectrometry
|
| Dibrom |
300-76-5 |
OSHA CSI
|
|
Sorbent Tube 226-30-16 Pump 210-5001
|
GC-FPD — Gas Chromatography-Flame Photometricdetector
|
| 1,2-Dibromo-3-chloropropane (DBCP) |
96-12-8 |
OSHA CSI
|
|
Sorbent Tube 226-81A Pump 210-1002MH
|
GC-ECD — Gas Chromatography-Electron Capture Detector
|
| Dibromodifluoromethane (difluorodibromomethane) |
75-61-6 |
NIOSH 1012
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| 1,2-Dibromoethane (ethylene dibromide) |
106-93-4 |
NIOSH 1008
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-ECD — Gas Chromatography-Electron Capture Detector
|
| 1,2-Dibromoethane (ethylene dibromide) |
106-93-4 |
ASTM D 5466
|
|
Canister 228 Series Passive Kit for Canisters 228 Series
|
GC-MS — Gas Chromatography -Mass Spectroscopy
|
| 1,2-Dibromoethane (ethylene dibromide) (see Passive Sampling Guide) |
106-93-4 |
|
|
Passive Sampler 575-001
|
|
| Dibutyl amine |
111-92-2 |
OSHA CSI
|
|
Impinger 225-36-2 Impinger Trap 225-22 Pump 210-5001
|
GC-NPD — Gas Chromatography-Nitrogen-Phosphorus Detector
|
| 2-Dibutyl aminoethanol (aminoethanol compounds I) |
102-81-8 |
NIOSH 2007
|
|
Sorbent Tube 226-10-04 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dibutyl phosphate |
107-66-4 |
NIOSH 5017
|
|
Filter 225-17-01 Filter Cassette 225-2LF Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
GC-FPD — Gas Chromatography-Flame Photometricdetector
|
| Dibutyl phthalate (DBP) |
84-74-2 |
|
|
Sorbent Tube 226-56 Pump 210-5001
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dibutyl phthalate |
84-74-2 |
NIOSH 5020
|
|
Preloaded Filter Cassette 225-3-01 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dibutyltin bis (isooctyl mercaptoacetate) (organotin compounds as Sn) |
25168-24-5 |
NIOSH 5504
|
|
Sorbent Tube 226-30 Preloaded Filter Cassette 225-709 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC & AA-GF — High-performance Liquid Chromatography and AA-GF — Atomic Absorption Spectroscopy-Graphite Furnace
|
| Dibutyltin dilaurate (as Sn) |
77-58-7 |
|
|
Preloaded Filter Cassette 225-3-01 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
AA — Atomic Absorption Spectroscopy
|
| Dibutyltin maleate (as Sn) |
15535-69-0 |
|
|
Preloaded Filter Cassette 225-3-01 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
AA-GF — Atomic Absorption Spectroscopy-Graphite Furnace
|
| Dicamba sodium salt |
1982-69-0 |
OSHA CSI
|
|
Preloaded Filter Cassette 225-709 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Dicamba |
1918-00-9 |
OSHA CSI
|
|
Preloaded Filter Cassette 225-709 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| 3,3-Dichloro-1,1,1,2,2-pentafluoropropane |
422-56-0 |
OSHA CSI
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| 2,2-Dichloro-1,1,1-trifluoroethane |
306-83-2 |
NON 50
|
|
Sorbent Tube 226-09 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| 1,3-Dichloro-1,1,2,2,3-pentafluoropropane |
507-55-1 |
OSHA CSI
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| 1,1-Dichloro-1-fluoroethane |
1717-00-6 |
|
|
Sorbent Tube not available from SKC
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| 1,1-Dichloro-1-nitroethane |
594-72-9 |
|
|
Sorbent Tube 226-81A Pump 210-5001
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| 1,1-Dichloro-1-nitroethane |
594-72-9 |
OSHA CSI
|
|
Sorbent Tube 226-81A Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| 1,1-Dichloro-1-nitroethane |
594-72-9 |
NIOSH 1601
|
|
Sorbent Tube 226-81A Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dichloroacetylene |
7572-29-4 |
OSHA CSI
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| 3,4-Dichloroaniline |
95-76-1 |
OSHA CSI
|
|
Preloaded Filter Cassette 225-803 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC — High-performance Liquid Chromatography
|
| p-Dichlorobenzene |
106-46-7 |
ASTM D 5466
|
|
Canister 228 Series Passive Kit for Canisters 228 Series
|
GC-MS — Gas Chromatography -Mass Spectroscopy
|
| p-Dichlorobenzene |
106-46-7 |
|
1121
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| o-Dichlorobenzene (see Passive Sampling Guide) |
95-50-1 |
|
|
Passive Sampler 575-001
|
|
| o-Dichlorobenzene |
95-50-1 |
|
1122
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| o-Dichlorobenzene (hydrocarbons, halogenated) |
95-50-1 |
NIOSH 1003
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| o-Dichlorobenzene |
95-50-1 |
ASTM D 5466
|
|
Canister 228 Series Passive Kit for Canisters 228 Series
|
GC-MS — Gas Chromatography -Mass Spectroscopy
|
| m-Dichlorobenzene (see Passive Sampling Guide) |
106-46-7 |
|
|
Passive Sampler 575-001
|
|
| p-Dichlorobenzene (see Passive Sampling Guide) |
106-46-7 |
|
|
Passive Sampler 575-001
|
|
| p-Dichlorobenzene (hydrocarbons, halogenated) |
106-46-7 |
NIOSH 1003
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| m-Dichlorobenzene |
541-73-1 |
ASTM D 5466
|
|
Canister 228 Series Passive Kit for Canisters 228 Series
|
GC-MS — Gas Chromatography -Mass Spectroscopy
|
| m-Dichlorobenzene |
541-73-1 |
OSHA CSI
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| 3,3'-Dichlorobenzidine |
91-94-1 |
|
1238
|
Coated Filter in Preloaded Cassette 225-9004 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
GC-ECD — Gas Chromatography-Electron Capture Detector
|
| Dichlorodifluoroethane |
1649-08-7 |
OSHA CSI
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dichlorodifluoromethane |
75-71-8 |
NIOSH 1018
|
|
Sorbent Tube 226-01 Sorbent Tube 226-09 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| 1,2-Dichloroethane (ethylene dichloride) |
107-06-2 |
|
1119
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| 1,2-Dichloroethane (ethylene dichloride) (see Passive Sampling Guide) |
107-06-2 |
|
|
Passive Sampler 575-001
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| 1,2-Dichloroethane (ethylene dichloride) (see Passive Sampling Guide) |
107-06-2 |
|
|
Passive Sampler 575-001
|
|
| 1,1-Dichloroethane (ethylidene chloride) |
75-34-3 |
ASTM D 5466
|
|
Canister 228 Series Passive Kit for Canisters 228 Series
|
GC-MS — Gas Chromatography -Mass Spectroscopy
|
| 1,1-Dichloroethane (ethylidene chloride) |
75-34-3 |
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| 1,1-Dichloroethane (hydrocarbons, halogenated) |
75-34-3 |
NIOSH 1003
|
1267
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| trans-1,2-Dichloroethylene (see Passive Sampling Guide) |
540-59-0 |
|
|
Detector Tube 810-174D
|
|
| cis-1,2-Dichloroethylene (see Passive Sampling Guide) |
540-59-0 |
|
|
Detector Tube 810-174D
|
|
| 1,2-Dichloroethylene (see Passive Sampling Guide) |
540-59-0 |
|
|
Passive Sampler 575-001
|
|
| 1,2-Dichloroethylene (hydrocarbons, halogenated) |
540-59-0 |
NIOSH 1003
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| 1,2-Dichloroethylene |
540-59-0 |
|
1118
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| cis-1,2-Dichloroethylene |
156-59-2 |
ASTM D 5466
|
|
Canister 228 Series Passive Kit for Canisters 228 Series
|
GC-MS — Gas Chromatography -Mass Spectroscopy
|
| Dichloroethyl ether |
111-44-4 |
|
|
Sorbent Tube 226-01 Pump 210-5001
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dichloroethyl ether (see Passive Sampling Guide) |
111-44-4 |
|
|
Passive Sampler 575-001
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dichloroethyl ether |
111-44-4 |
NIOSH 1004
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dichlorofluoromethane |
75-43-4 |
NIOSH 2516
|
|
Sorbent Tube 226-25 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dichloromethane (see methylene chloride) |
75-09-2 |
|
|
|
|
| Dichloromethane |
75-09-2 |
ASTM D 5466
|
|
Canister 228 Series Passive Kit for Canisters 228 Series
|
GC-MS — Gas Chromatography -Mass Spectroscopy
|
| Dichloromonofluoromethane (dichlorofluoromethane) |
75-43-4 |
NIOSH 2516
|
|
Sorbent Tube 226-09 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dichloromonofluoromethane (dichlorofluoromethane) |
75-43-4 |
OSHA CSI
|
|
Sorbent Tube 226-09 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| 2,4-Dichlorophenoxyacetic acid (2,4-D) |
94-75-7 |
NIOSH 5001
|
|
Preloaded Filter Cassette 225-709 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| 1,2-Dichloropropane (propylene dichloride) |
78-87-5 |
ASTM D 5466
|
|
Canister 228 Series Passive Kit for Canisters 228 Series
|
GC-MS — Gas Chromatography -Mass Spectroscopy
|
| 1,2-Dichloropropane (propylene dichloride) |
78-87-5 |
NIOSH 1013
|
|
Sorbent Tube 226-81A Pump 210-1002MH
|
GC-ECN — Gas Chromatography-Electrolytic Conductivity Detector
|
| 1,2-Dichloropropane (propylene dichloride) (see Passive Sampling Guide) |
78-87-5 |
|
|
Passive Sampler 575-001
|
|
| trans-1,3-Dichloropropene |
542-75-6 |
ASTM D 5466
|
|
Canister 228 Series Passive Kit for Canisters 228 Series
|
GC-MS — Gas Chromatography -Mass Spectroscopy
|
| cis-1,3-Dichloropropene |
542-75-6 |
ASTM D 5466
|
|
Canister 228 Series Passive Kit for Canisters 228 Series
|
GC-MS — Gas Chromatography -Mass Spectroscopy
|
| 1,3-Dichloropropene |
542-75-6 |
OSHA CSI
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| cis-1,3-Dichloropropene (see Passive Sampling Guide) |
542-75-6 |
|
|
Passive Sampler 575-001
|
|
| 3,4-Dichloropropionanilide |
709-98-8 |
OSHA CSI
|
|
Filter 225-7
|
W — Wipe
|
| 2,2-Dichloropropionic acid |
75-99-0 |
|
|
Sorbent Tube 226-10 Pump 210-1002MH
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Dichlorotetrafluoroethane |
1320-37-2 |
OSHA CSI
|
|
Sorbent Tube 226-09 Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| 1,1-Dichlorotetrafluoroethane |
374-07-2 |
OSHA CSI
|
|
Sorbent Tube 226-01 Sorbent Tube 226-09 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| 1,2-Dichlorotetrafluoroethane (dichlorodifluoromethane) |
76-14-2 |
NIOSH 1018
|
|
Sorbent Tube 226-01 Sorbent Tube 226-09 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dichlorotrifluoroethane |
306-83-2 |
NON 50
|
|
Sorbent Tube 226-09 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dichlorvos (DDVP) |
62-73-7 |
ASTM D 4861
|
|
PUF Tube 226-92 Pump 210-5001
|
GC-ECD — Gas Chromatography-Electron Capture Detector
|
| Dichlorvos (DDVP) |
62-73-7 |
|
1395
|
Sorbent Tube 226-30-16 Pump 210-5001
|
GC-FPD — Gas Chromatography-Flame Photometricdetector
|
| Dicloran |
99-30-9 |
ASTM D 4861
|
|
PUF Tube 226-92 Pump 210-5001
|
GC-ECD — Gas Chromatography-Electron Capture Detector
|
| Dicofol |
115-32-2 |
ASTM D 4861
|
|
PUF Tube 226-92 Pump 210-5001
|
GC-ECD — Gas Chromatography-Electron Capture Detector
|
| Dicofol |
115-32-2 |
OSHA CSI
|
|
Smear Tab 225-24
|
W — Wipe
|
| Dicrotophos |
141-66-2 |
ASTM D 4861
|
|
PUF Tube 226-92 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Dicrotophos (Bidrin) |
141-66-2 |
|
|
Sorbent Tube 226-30-16 Pump 210-5001
|
GC-FPD — Gas Chromatography-Flame Photometricdetector
|
| Dicrotophos (organophosphorus pesticides) |
141-66-2 |
NIOSH 5600
|
|
Sorbent Tube 226-58 Pump 210-5001
|
GC-FPD — Gas Chromatography-Flame Photometricdetector
|
| Dicyclopentadiene |
77-73-6 |
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dicyclopentadiene (see Passive Sampling Guide) |
77-73-6 |
|
|
Passive Sampler 575-001
|
|
| Dicyclopentadienyl iron (respirable dust) |
102-54-5 |
OSHA CSI
|
|
Filter 225-8-01 Filter Cassette and Cyclone Holder 225-1 Filter Cassette 225-3LF
|
GR — Gravimetric Analysis
|
| Dicyclopentadienyl iron (total dust) |
102-54-5 |
OSHA CSI
|
|
Preloaded Filter Cassette 225-3-01 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
AA — Atomic Absorption Spectroscopy
|
| Dieldrin |
60-57-1 |
OSHA CSI
|
|
Preloaded Filter Cassette 225-709 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
GC-ECD — Gas Chromatography-Electron Capture Detector
|
| Dieldrin |
60-57-1 |
ASTM D 4861
|
|
PUF Tube 226-92 Pump 210-5001
|
GC-ECD — Gas Chromatography-Electron Capture Detector
|
| Diesel exhaust particles (see elemental carbon) |
|
NIOSH 5040
|
|
|
TOA-FID — Thermal Optical Analysis-Flame Ionization Detector
|
| Diesel emissions (see elemental carbon) |
|
NIOSH 5040
|
|
|
TOA-FID — Thermal Optical Analysis-Flame Ionization Detector
|
| Diesel particulate matter |
|
ASTM D 6877
|
|
Diesel Particulate Matter Cassette 225-317 or Preloaded Filter Cassette 225-401 Pump 210-5001
|
EGA-TOS — Evolved Gas Analysis With Thermal-Optical Sensor
|
| Diesel particulate matter |
|
MSHA 30CFR57
|
|
Diesel Particulate Matter Cassette 225-317 Cyclone 225-100 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
TOA-FID — Thermal Optical Analysis-Flame Ionization Detector
|
| Diesel particulate matter |
|
MSHA 30CFR57
|
|
Preloaded Filter Cassette 225-401 Cyclone 225-100 Filter Cassette and Cyclone Holder 225-1
|
TOA-FID — Thermal Optical Analysis-Flame Ionization Detector
|
| Diethanolamine |
111-42-2 |
|
|
Sorbent Tube 226-30-18 Pump 210-1002MH
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Diethanolamine (DEA) (aminoethanol compounds II) |
111-42-2 |
NIOSH 3509
|
1006
|
Impinger 225-36-1 Impinger Trap 225-22 Pump 210-5001
|
IC — Ion Chromatography
|
| N,N-Diethylamine (see Passive Sampling Guide) |
109-89-7 |
|
|
Detector Tube 810-3D
|
|
| Diethylamine (amines, aliphatic) |
109-89-7 |
NIOSH 2010
|
|
Sorbent Tube 226-10 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Diethylamine |
109-89-7 |
|
1697
|
Sorbent Tube 226-96 Pump 210-1002MH
|
HPLC — High-performance Liquid Chromatography
|
| 2-Diethylaminoethanol |
100-37-8 |
OSHA CSI
|
|
Sorbent Tube 226-10-04 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| 2-Diethylaminoethanol (aminoethanol compounds I) |
100-37-8 |
NIOSH 2007
|
|
Sorbent Tube 226-10-04 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Diethylaminopropylamine (DEP) |
104-78-9 |
OSHA CSI
|
|
Impinger 225-36-1 Impinger Trap 225-22 Pump 210-5001
|
GC-NPD — Gas Chromatography-Nitrogen-Phosphorus Detector
|
| Diethylene dioxide (see dioxane) |
123-91-1 |
|
|
|
|
| Diethylene ether (see dioxane) |
123-91-1 |
|
|
|
|
| Diethylene glycol (glycols) |
111-46-6 |
NIOSH 5523
|
1387
|
Sorbent Tube 226-57 Pump 210-5001
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Di(ethyleneglycol) ethyl ether acrylate |
7328-17-8 |
|
|
Sorbent Tube 226-110 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Diethylene glycol methyl ether |
111-77-3 |
OSHA CSI
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Diethylene glycol monobutyl ether acetate |
124-17-4 |
OSHA CSI
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Diethylene glycol monoethyl ether |
111-90-0 |
OSHA CSI
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Diethylenetriamine |
111-40-0 |
|
1285
|
Sorbent Tube 226-30-18 Pump 210-1002MH
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Diethyl ether (ethyl ether) |
60-29-7 |
NIOSH 1610
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Diethyl ether (ethyl ether) (see Passive Sampling Guide) |
60-29-7 |
|
|
Passive Sampler 575-001
|
|
| Diethyl ketone (3-pentanone) |
96-22-0 |
OSHA CSI
|
|
Sorbent Tube not available from SKC
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Diethyl ketone (3-pentanone) (see Passive Sampling Guide) |
96-22-0 |
|
|
Passive Sampler 575-002
|
|
| Diethyl phthalate (DEP) |
84-66-2 |
|
|
Sorbent Tube 226-56 Pump 210-5001
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Diethyl sulfate |
64-67-5 |
OSHA CSI
|
|
Sorbent Tube 226-10 Pump 210-5001
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Difluorodibromomethane |
75-61-6 |
NIOSH 1012
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Difluorodibromomethane |
75-61-6 |
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Diglycidyl ether of bisphenol A |
1675-54-3 |
OSHA CSI
|
|
Preloaded Filter Cassette 225-709 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Diglycolamine |
929-06-6 |
OSHA CSI
|
|
Impinger 225-36-1 Impinger Trap 225-22 Pump 210-1002MH
|
GC-NPD — Gas Chromatography-Nitrogen-Phosphorus Detector
|
| Diglyme |
111-96-6 |
OSHA CSI
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dihexyl phthalate |
84-75-3 |
|
|
Sorbent Tube 226-56 Pump 210-5001
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dihydrocapsaicin |
19408-84-5 |
NIOSH 5041
|
|
Filter 225-16 Filter Cassette 225-32 Pump 210-5001
|
HPLC-FD — High-performance Liquid Chromatography With Fluorescence Detector
|
| Diisobutyl ketone |
108-83-8 |
|
1116
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Diisobutyl ketone (DIBK) (see Passive Sampling Guide) |
108-83-8 |
|
|
Passive Sampler 575-002
|
|
| Diisobutyl ketone (ketones I) |
108-83-8 |
NIOSH 1300
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Diisobutyl ketone (ketones I) |
108-10-1 |
NIOSH 2555
|
|
Sorbent Tube not available from SKC
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Diisocyanates |
|
|
1458
|
Coated Filter in Preloaded Cassette 225-9002 or Coated Filter in Preloaded Cassette 225-9013 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector or HPLC-FD — High-performance Liquid Chromatography With Fluorescence Detector
|
| Diisopropylamine |
108-18-9 |
OSHA CSI
|
|
Impinger 225-36-1 Impinger Trap 225-22 Pump 210-5001
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dimethazone |
81777-89-1 |
|
|
Sorbent Tube 226-30-16 Pump 210-5001
|
GC-ECD — Gas Chromatography-Electron Capture Detector
|
| Dimethoate |
60-51-5 |
|
|
Sorbent Tube 226-30-16 Pump 210-5001
|
GC-FPD — Gas Chromatography-Flame Photometricdetector
|
| 2,5-Dimethoxyaniline |
102-56-7 |
OSHA CSI
|
|
Sorbent Tube 226-30-04 Pump 210-1002MH
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Dimethoxymethane (methylal) |
109-87-5 |
NIOSH 1611
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dimethoxymethane (methylal) (see Passive Sampling Guide) |
109-87-5 |
|
|
Passive Sampler 575-001
|
|
| Dimethoxymethane (methylal) |
109-87-5 |
|
1115
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dimethyl-1,2-dibromo-2,2-dichloroethyl phosphate |
300-76-5 |
OSHA CSI
|
|
Sorbent Tube 226-30-16 Pump 210-5001
|
GC-FPD — Gas Chromatography-Flame Photometricdetector
|
| 2,3-Dimethyl-2,3-dinitrobutane |
3964-18-9 |
NON 44
|
|
Sorbent Tube 226-35-03 Pump 210-1002MH
|
GC-ECD — Gas Chromatography-Electron Capture Detector
|
| Dimethylacetamide |
127-19-5 |
OSHA CSI
|
|
Sorbent Tube 226-10 Pump 210-5001
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dimethylacetamide |
127-19-5 |
NIOSH 2004
|
1695
|
Sorbent Tube 226-10 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dimethyl adipate |
627-93-0 |
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dimethylamine |
124-40-3 |
NIOSH 2010
|
|
Sorbent Tube 226-10 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dimethylamine (see Passive Sampling Guide) |
124-40-3 |
|
|
Detector Tube 810-3D
|
|
| Dimethylamine (see Passive Sampling Guide) |
124-40-3 |
|
|
Passive Sampler 500-400
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Dimethylamine |
124-40-3 |
|
1696
|
Sorbent Tube 226-96 Pump 210-1002MH
|
HPLC — High-performance Liquid Chromatography
|
| 4-Dimethylaminoazobenzene |
60-11-7 |
OSHA CSI
|
|
Preloaded Filter Cassette 225-706 Filter Cassette and Cyclone Holder 225-1 Impinger 225-36-1 Impinger Trap 225-22 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| 2,4-Dimethylaminobenzene (amines, aromatic) |
1300-73-8 |
NIOSH 2002
|
|
Sorbent Tube 226-10 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector or Gas Chromatography-Nitrogen Specific Detector
|
| Dimethylaminobenzene |
1300-73-8 |
OSHA CSI
|
|
Sorbent Tube 226-10 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| 2-Dimethylamino ethanol |
108-01-0 |
NIOSH 2561
|
|
Sorbent Tube 226-94 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| 1-Dimethylamino-2-propanol |
108-16-7 |
NIOSH 2561
|
|
Sorbent Tube 226-94 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| N,N-Dimethylaniline (amines, aromatic) |
121-69-7 |
NIOSH 2002
|
1054
|
Sorbent Tube 226-10 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector or Gas Chromatography-Nitrogen Specific Detector
|
| N,N-Dimethylaniline |
121-69-7 |
|
|
Sorbent Tube 226-98 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| N,N-Dimethylaniline |
121-69-7 |
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| N,N-Dimethylaniline (see Passive Sampling Guide) |
121-69-7 |
|
|
Passive Sampler 575-001
|
|
| Dimethyl arsenic acid (arsenic, organo-) |
75-60-5 |
NIOSH 5022
|
|
Filter 225-17-01 Filter Cassette 225-2LF Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
IC-AA — Ion Chromatography With Atomic Absorption Spectrophotometer Detector
|
| 2,5-Dimethylbenzaldehyde |
5779-94-2 |
ASTM D 5197
|
|
Sorbent Tube 226-120 or Sorbent Tube 226-119 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| trans-1,2-Dimethylcyclohexane (see Passive Sampling Guide) |
6876-23-9 |
|
|
Passive Sampler 575-001
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| trans-1,4-Dimethylcyclohexane |
2207-04-7 |
OSHA CSI
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dimethyl disulfide |
624-92-0 |
NON 42
|
1413
|
Sample Bag 253-10 or Sample Bag 263-10 Pump 222-3
|
GC-FPD — Gas Chromatography-Flame Photometricdetector
|
| Dimethyl disulfide |
624-92-0 |
OSHA CSI
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| N,N-Dimethylethanolamine |
108-01-0 |
NIOSH 2561
|
|
Sorbent Tube 226-94 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| N,N-Dimethylethanolamine |
108-01-0 |
OSHA CSI
|
|
Sorbent Tube 226-10-04 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| N,N-Dimethylethylamine |
598-56-1 |
|
|
Sorbent Tube 226-18 Pump 210-1002MH
|
GC-NPD — Gas Chromatography-Nitrogen-Phosphorus Detector
|
| N,N-Dimethylformamide (see Passive Sampling Guide) |
68-12-2 |
|
|
Passive Sampler 575-002
|
|
| N,N-Dimethylformamide |
68-12-2 |
NIOSH 2004
|
|
Sorbent Tube 226-10 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| N,N-Dimethylformamide |
68-12-2 |
|
1271
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-NPD — Gas Chromatography-Nitrogen-Phosphorus Detector
|
| Dimethyl glutarate |
1119-40-0 |
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| 1,1-Dimethylhydrazine |
57-14-7 |
OSHA CSI
|
|
Impinger 225-36-2 Impinger Trap 225-22 Pump 210-1002MH
|
CLR — Spectrophotometric Method or Colorimeter
|
| 1,1-Dimethylhydrazine |
57-14-7 |
NIOSH 3515
|
|
Impinger 225-36-2 Impinger Trap 225-22 Pump 210-5001
|
VAS — Visible Absorption Spectrophotometry
|
| Dimethyl phthalate (DMP) |
131-11-3 |
|
|
Sorbent Tube 226-56 Pump 210-5001
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| N,N-Dimethyl-p-toluidine (amines, aromatic) |
99-97-8 |
NIOSH 2002
|
1055
|
Sorbent Tube 226-10 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector or Gas Chromatography-Nitrogen Specific Detector
|
| Dimethyl succinate |
106-65-0 |
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dimethyl sulfate |
77-78-1 |
NIOSH 2524
|
1284
|
Sorbent Tube 226-114 Pump 210-1002MH
|
GC-ECN — Gas Chromatography-Electrolytic Conductivity Detector
|
| Dimethyl sulfate |
77-78-1 |
|
|
Sorbent Tube 226-115 Pump 210-1002MH
|
GC-FPD — Gas Chromatography-Flame Photometricdetector
|
| Dimethyl sulfide |
75-18-3 |
NON 42
|
1413
|
Sample Bag 245-08 Pump 222-3
|
GC-FPD — Gas Chromatography-Flame Photometricdetector
|
| Dimethyl sulfide |
75-18-3 |
OSHA CSI
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FPD — Gas Chromatography-Flame Photometricdetector
|
| Dimethyl sulfoxide |
67-68-5 |
OSHA CSI
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dimethyltin dichloride |
753-73-1 |
NIOSH 5526
|
|
Sorbent Tube 226-30-16 Pump 210-5001
|
GC-FPD — Gas Chromatography-Flame Photometricdetector
|
| Di-n-hexyl phthalate |
84-75-3 |
|
|
Sorbent Tube 226-56 Pump 210-5001
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dinitolmide |
148-01-6 |
OSHA CSI
|
|
Preloaded Filter Cassette 225-706 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC — High-performance Liquid Chromatography
|
| Dinitrobenzene (all isomers) |
25154-54-5 |
OSHA CSI
|
|
Sorbent Tube 226-30-16 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Dinitro-o-cresol |
534-52-1 |
OSHA CSI
|
|
Preloaded Filter Cassette 225-3-01 Impinger 225-36-1 Impinger Trap 225-22 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| 4,6-Dinitro-o-sec-butyl phenol |
88-85-7 |
OSHA CSI
|
|
Sorbent Tube 226-95 Pump 210-1002MH
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| 2-(2,4-Dinitrophenoxy)ethanol |
138-93-2 |
OSHA CSI
|
|
Sorbent Tube 226-10 Pump 210-1002MH
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Dinitrotoluene (DNT) |
25321-14-6 |
|
|
Sorbent Tube 226-56 Pump 210-5001
|
GC-TEA — Gas Chromatography With Thermal Energy Analyzer
|
| Di-n-octyl phthalate (DNOP) |
117-84-0 |
|
|
Sorbent Tube 226-56 Pump 210-5001
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Di-n-octyl-phthalate (DNOP) |
117-84-0 |
OSHA CSI
|
|
Sorbent Tube 226-56 Pump 210-5001
|
GC-ECD — Gas Chromatography-Electron Capture Detector
|
| n-Dioctyl phthalate (DNOP) |
117-84-0 |
|
|
Sorbent Tube 226-56 Pump 210-5001
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dioxane (diethylene dioxide) (see Passive Sampling Guide) |
123-91-1 |
|
|
Passive Sampler 575-002
|
|
| Dioxane (diethylene dioxide) |
123-91-1 |
NIOSH 1602
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dioxane (diethylene dioxide) |
123-91-1 |
|
1114
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dioxathion (Delnav) |
78-34-2 |
OSHA CSI
|
|
Sorbent Tube 226-30-16 Pump 210-5001
|
GC-FPD — Gas Chromatography-Flame Photometricdetector
|
| Dioxins (including PHDDs, PCDDs, PBDDs) (see Environmental Sampling Guide) |
|
|
|
|
|
| Diphenyl |
92-54-4 |
NIOSH 2530
|
|
Sorbent Tube 226-35-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| 2-Diphenylacetyl-1,3-indandione |
82-66-6 |
OSHA CSI
|
|
Preloaded Filter Cassette 225-706 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Diphenylamine |
122-39-4 |
|
1229
|
Coated Filter in Preloaded Cassette 225-9004 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Diphenyl ether |
92-52-4 |
|
|
Sorbent Tube 226-95 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| 5,5-Diphenylhydantoin |
57-41-0 |
OSHA CSI
|
|
Filter 225-7 Filter Cassette 225-3LF Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Diphenylmethane-4,4'-diisocyanate (4,4-methylene bisphenyl isocyanate) (isocyanates) |
101-68-8 |
NIOSH 5521
|
1001
|
Impinger 225-36-1 Impinger Trap 225-22 Pump 210-5001
|
HPLC ELCHEM — High-performance Liquid Chromatography With Electrochemical Detector and HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| p,p-Diphenyl methane diisocyanate (MDI) (see methylene bisphenyl isocyanate) |
101-68-8 |
|
|
|
|
| Dipropyl disulfide |
629-19-6 |
|
|
Sorbent Tube 226-110 Pump 210-1002MH
|
GC-FPD — Gas Chromatography-Flame Photometricdetector
|
| Dipropylene glycol methyl ether |
34590-94-8 |
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dipropylene glycol methyl ether (glycol ethers) |
34590-94-8 |
NIOSH 2554
|
|
Sorbent Tube 226-81A Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dipropylene glycol methyl ether |
34590-94-8 |
|
1113
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dipropylene glycol methyl ether (see Passive Sampling Guide) |
34590-94-8 |
|
|
Passive Sampler 575-002
|
|
| Dipropylene glycol monomethyl ether (glycol ethers) |
34590-94-8 |
NIOSH 2554
|
|
Sorbent Tube 226-81A Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dipropyl ketone |
123-19-3 |
OSHA CSI
|
|
Sorbent Tube not available from SKC
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dipropyl ketone (4-heptanone) (see Passive Sampling Guide) |
123-19-3 |
|
|
Passive Sampler 575-002
|
|
| Diquat |
85-00-7 |
OSHA CSI
|
|
Preloaded Filter Cassette 225-709 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Direct black 38 |
1937-37-7 |
OSHA CSI
|
|
Preloaded Filter Cassette 225-706 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC — High-performance Liquid Chromatography
|
| Direct black 38 (dyes, benzidine) |
1937-37-7 |
NIOSH 5013
|
|
Filter 225-17A Filter Cassette 225-3LF Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC — High-performance Liquid Chromatography
|
| Direct blue |
3841-14-3 |
OSHA CSI
|
|
Preloaded Filter Cassette 225-709 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Direct blue 2 |
2429-73-4 |
OSHA CSI
|
|
Preloaded Filter Cassette 225-709 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Direct blue 6 (dyes, benzidine) |
2602-46-2 |
NIOSH 5013
|
|
Filter 225-17A Filter Cassette 225-3LF Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC — High-performance Liquid Chromatography
|
| Direct blue 6 |
2602-46-2 |
OSHA CSI
|
|
Preloaded Filter Cassette 225-709 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Direct blue 8 (dyes, benzidine) |
2429-71-2 |
NIOSH 5013
|
|
Filter 225-17A Filter Cassette 225-3LF Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC — High-performance Liquid Chromatography
|
| Direct blue 98 |
6656-03-7 |
OSHA CSI
|
|
Preloaded Filter Cassette 225-706 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Direct brown 31 |
2429-81-4 |
OSHA CSI
|
|
Preloaded Filter Cassette 225-706 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Direct brown 95 (dyes, benzidine) |
16071-86-6 |
NIOSH 5013
|
|
Filter 225-17A Filter Cassette 225-3LF Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC — High-performance Liquid Chromatography
|
| Direct brown 95 |
16071-86-6 |
OSHA CSI
|
|
Preloaded Filter Cassette 225-709 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Direct red 2 (dyes, benzidine) |
992-59-6 |
NIOSH 5013
|
|
Filter 225-17A Filter Cassette 225-3LF Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC — High-performance Liquid Chromatography
|
| Direct red 2 |
992-59-6 |
OSHA CSI
|
|
Preloaded Filter Cassette 225-709 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Direct red 28 (dyes, benzidine) |
573-58-0 |
NIOSH 5013
|
|
Filter 225-17A Filter Cassette 225-3LF Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC — High-performance Liquid Chromatography
|
| Direct red 81 |
2610-11-9 |
OSHA CSI
|
|
Preloaded Filter Cassette 225-709 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Di-sec-octyl phthalate (see di-[2-ethylhexy] phthalate) |
117-81-7 |
|
|
|
|
| Disperse yellow 3 |
2832-40-8 |
OSHA CSI
|
|
Preloaded Filter Cassette 225-709 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Disulfiram (tetraethylthiuram disulfide) |
97-77-8 |
OSHA CSI
|
|
Preloaded Filter Cassette 225-709 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Disulfoton |
298-04-4 |
|
|
Sorbent Tube 226-30-16 Pump 210-5001
|
GC-FPD — Gas Chromatography-Flame Photometricdetector
|
| Disulfoton (organophosphorus pesticides) |
298-04-4 |
NIOSH 5600
|
|
Sorbent Tube 226-58 Pump 210-5001
|
GC-FPD — Gas Chromatography-Flame Photometricdetector
|
| Disyston |
298-04-4 |
OSHA CSI
|
|
Sorbent Tube 226-30-16 Pump 210-5001
|
GC-FPD — Gas Chromatography-Flame Photometricdetector
|
| 2,2'-Dithiobis(benzothiazole) |
120-78-5 |
OSHA CSI
|
|
Preloaded Filter Cassette 225-706 Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Diuron |
330-54-1 |
ASTM D 4861
|
|
PUF Tube 226-92 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Diuron (organonitrogen pesticides) |
330-54-1 |
NIOSH 5601
|
|
Sorbent Tube 226-58 or Sorbent Tube 226-30-16 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Divinyl benzene |
1321-74-0 |
|
|
Sorbent Tube 226-73 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Divinyl sulfide |
627-51-0 |
OSHA CSI
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC — Gas Chromatography
|
| 2,4-D, ME (2,4-dichlorophenoxyacetic acid) |
1928-38-7 |
NIOSH 5602
|
|
Sorbent Tube 226-58 Pump 210-5001
|
GC-ECD — Gas Chromatography-Electron Capture Detector
|
| DMP (see dimethyl phthalate) |
131-11-3 |
|
|
|
|
| DNOP (see di-n-octyl phthalate) |
117-84-0 |
|
|
|
|
| DNT (dinitrotoluene) |
25321-14-6 |
|
|
Sorbent Tube 226-56 Pump 210-5001
|
GC-TEA — Gas Chromatography With Thermal Energy Analyzer
|
| Dodecyl alcohol (lauryl alcohol) |
112-53-8 |
OSHA CSI
|
|
Sorbent Tube 226-01 Pump 210-1002MH
|
GC-FID — Gas Chromatography-Flame Ionization Detector
|
| Dodecyl alcohol (lauryl alcohol) (see Passive Sampling Guide) |
112-53-8 |
|
|
Passive Sampler 575-001
|
|
| Dodine |
2439-10-3 |
OSHA CSI
|
|
Sorbent Tube 226-30 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Dursban (chlorpyrifos)(organophosphorus pesticides) |
2921-88-2 |
NIOSH 5600
|
|
Sorbent Tube 226-58 Pump 210-5001
|
GC-FPD — Gas Chromatography-Flame Photometricdetector
|
| Dust, inorganic |
|
|
|
Spore Trap Cassette 225-9820 Pump 228-9530
|
Varies — Analytical Method is dependant upon the nature of the sample. Refer to the method for details
|
| Dust, respirable (in workplace atmospheres) |
|
ASTM D 4532
|
1418
|
Filter 225-8-01 Filter Cassette and Cyclone Holder 225-1 Cyclone 225-01-02 Filter Cassette 225-3LF Pump 210-5001
|
GR — Gravimetric Analysis
|
| Dust, respirable nuisance |
|
OSHA CSI
|
|
Filter 225-8-01 Filter Cassette and Cyclone Holder 225-1 Cyclone 225-105 Filter Cassette 225-3LF
|
GR — Gravimetric Analysis
|
| Dust, respirable nuisance (particulates) |
|
NIOSH 0600
|
1038
|
Filter 225-8-01 Filter Cassette and Cyclone Holder 225-1 Cyclone 225-01-02 Filter Cassette 225-3LF Pump 210-5001
|
GR — Gravimetric Analysis
|
| Dust, total nuisance |
|
OSHA CSI
|
|
Filter 225-8-01 Filter Cassette and Cyclone Holder 225-1 Filter Cassette 225-2LF Pump 210-5001
|
GR — Gravimetric Analysis
|
| Dust, total nuisance (particulates) |
|
NIOSH 0500
|
1035
|
Filter 225-8-01 Filter Cassette and Cyclone Holder 225-1 Filter Cassette 225-2LF Pump 210-5001
|
GR — Gravimetric Analysis
|
| Dust, total, particulates not otherwise regulated |
|
NIOSH 0500
|
1035
|
Filter 225-8-01 Filter Cassette and Cyclone Holder 225-1 Filter Cassette 225-2LF Pump 210-5001
|
GR — Gravimetric Analysis
|
| Dyes, benzidine, o-tolidine, o-dianisidine |
|
NIOSH 5013
|
|
Filter 225-17A Filter Cassette 225-3LF Filter Cassette and Cyclone Holder 225-1 Pump 210-5001
|
HPLC-UV — High-performance Liquid Chromatography With UV Detector
|
| Dyfonate |
944-22-9 |
OSHA CSI
|
|
Sorbent Tube 226-30-16 Pump 210-5001
|
GC-FPD — Gas Chromatography-Flame Photometricdetector
|