SKC Guide to OSHA/NIOSH/ASTM Air Sampling Methods

Chemical Hazards that begin with X

Chemical CASNO
Method
CFF
Sampling Equipment
Analytical Method
Xylene (o-, m-, & p-isomers)     1746   Sorbent Tube  226-01  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector
m-Xylene 108-38-3    1746   Passive Sampler  575-002  
GC-FID — Gas Chromatography-Flame Ionization Detector
o-Xylene 95-47-6    ASTM D 5466   Canister  228 Series  
Passive Kit for Canisters  228 Series  
GC-MS — Gas Chromatography -Mass Spectroscopy
o-Xylene 95-47-6    1746   Passive Sampler  575-002  
GC-FID — Gas Chromatography-Flame Ionization Detector
p-Xylene 106-42-3    ASTM D 5466   Canister  228 Series  
Passive Kit for Canisters  228 Series  
GC-MS — Gas Chromatography -Mass Spectroscopy
p-Xylene 106-42-3    1746   Passive Sampler  575-002  
GC-FID — Gas Chromatography-Flame Ionization Detector
m-Xylene (hydrocarbons, aromatic) 108-38-3    NIOSH 1501   Sorbent Tube  226-01  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector
o-Xylene (hydrocarbons, aromatic) 95-47-6    NIOSH 1501   Sorbent Tube  226-01  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector
m-Xylene 108-38-3    ASTM D 5466   Canister  228 Series  
Passive Kit for Canisters  228 Series  
GC-MS — Gas Chromatography -Mass Spectroscopy
Xylene (o-, m-, & p-isomers)     1186   Sorbent Tube  226-01  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector
Xylene (see Passive Sampling Guide) 1330-20-7      Detector Tube  810-122DL  
 
m-Xylene (see Passive Sampling Guide) 108-38-3      Passive Sampler  575-001 or
Passive Sampler  575-002  
GC-FID — Gas Chromatography-Flame Ionization Detector
o-Xylene (see Passive Sampling Guide) 95-47-6      Passive Sampler  575-001  
GC-FID — Gas Chromatography-Flame Ionization Detector
p-Xylene (see Passive Sampling Guide) 106-42-3      Passive Sampler  575-001 or
Passive Sampler  575-002  
GC-FID — Gas Chromatography-Flame Ionization Detector
p-Xylene (hydrocarbons, aromatic) 106-42-3    NIOSH 1501   Sorbent Tube  226-01  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector
m-Xylenediamine (mXDA) 1477-55-0    1405   Coated Filter in Preloaded Cassette  225-9004  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
HPLC-UV — High-performance Liquid Chromatography With UV Detector
p-Xylenediamine (pXDA) 539-48-0    1405   Coated Filter in Preloaded Cassette  225-9004  
Filter Cassette and Cyclone Holder  225-1  
Pump 210-5001
HPLC-UV — High-performance Liquid Chromatography With UV Detector
2,4-Xylidine (amines, aromatic) 1300-73-8    NIOSH 2002 1056   Sorbent Tube  226-10  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector or Gas Chromatography-Nitrogen Specific Detector
Xylidine 1300-73-8    OSHA CSI   Sorbent Tube  226-10  
Pump 210-1002MH
GC-FID — Gas Chromatography-Flame Ionization Detector

Chemical Hazards by First Letter

A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z

 

Chemical Hazard Search:  
  Enter chemical name in box above

CAS No. Search:  
  Enter CAS number in box above

Method Number Search:  
  Enter method number in box above

Catalog Number Search:  
  Enter the exact SKC catalog number in the box


This SKC Air Sampling Guide is a reference only to assist users in finding the method, sampling equipment, and sampling media for a specific compound. This publication is intended for general information only and should not be used as a substitute for reviewing applicable government regulations, equipment operating instructions, or legal standards. Users must consult the appropriate sampling method for the compound of interest before sampling. The sampling parameters shown here are suggestions based on the ranges or volume, flow, and time specified in the methods. It is the responsibility of the analyst performing the sampling and analysis steps to adjust the parameters so that the required detection limits can be obtained. The information contained in this document should not be construed as legal advice or opinion nor as a final authority on legal or regulatory procedures.