Chemical Hazard
CAS No.
Sampler
Validation
Level
Analytical Method
Terpineol
98-55-5
575-003 Passive Sampler for Organic Vapor, Anasorb 727 sorbent   GC-FID — Gas Chromatography - Flame Ionization Detector
1,1,1,2-Tetrachloroethane
25322-20-7
690-101 Ultra III Passive Sampler, GCB1  or
690-103 Ultra III Passive Sampler, Chromosorb 106  or
690-104 Ultra III Passive Sampler, Tenaz TA   
TD, GC — Thermal Desorption - Gas Chromatography
1,1,2,2-Tetrachloroethane
79-34-5
575-001 Passive Sampler for Organic Vapor, Charcoal sorbent   GC-FID — Gas Chromatography - Flame Ionization Detector
1,1,2,2-Tetrachloroethane
79-34-5
690-101 Ultra III Passive Sampler, GCB1  or
690-103 Ultra III Passive Sampler, Chromosorb 106  or
690-104 Ultra III Passive Sampler, Tenaz TA   
TD, GC — Thermal Desorption - Gas Chromatography
Tetrachloroethylene (perchloroethylene)
127-18-4
575-001 Passive Sampler for Organic Vapor, Charcoal sorbent   GC-FID — Gas Chromatography - Flame Ionization Detector
Tetrachloroethylene (perchloroethylene)
127-18-4
575-002 Passive Sampler for Organic Vapor, Anasorb® 747 sorbent   GC-FID — Gas Chromatography - Flame Ionization Detector
Tetrachloroethylene (perchloroethylene)
127-18-4
690-101 Ultra III Passive Sampler, GCB1  or
690-103 Ultra III Passive Sampler, Chromosorb 106  or
690-104 Ultra III Passive Sampler, Tenaz TA   
TD, GC — Thermal Desorption - Gas Chromatography
Tetrachloroethylene (perchloroethylene)
127-18-4
810-133D Gastec Color Dosimeter Tube  
DR — Direct Reading
Tetrahydrofuran
109-99-9
575-001 Passive Sampler for Organic Vapor, Charcoal sorbent   GC-FID — Gas Chromatography - Flame Ionization Detector
Tetrahydrofuran
109-99-9
575-002 Passive Sampler for Organic Vapor, Anasorb® 747 sorbent   GC-FID — Gas Chromatography - Flame Ionization Detector
1,2,3,4-Tetramethylbenzene
488-23-3
575-001 Passive Sampler for Organic Vapor, Charcoal sorbent   GC-FID — Gas Chromatography - Flame Ionization Detector
1,2,3,5-Tetramethylbenzene
527-53-7
575-001 Passive Sampler for Organic Vapor, Charcoal sorbent   GC-FID — Gas Chromatography - Flame Ionization Detector
1,2,4,5-Tetramethylbenzene
95-93-2
575-001 Passive Sampler for Organic Vapor, Charcoal sorbent   GC-FID — Gas Chromatography - Flame Ionization Detector
Toluene
108-88-3
575-001 Passive Sampler for Organic Vapor, Charcoal sorbent   GC-FID — Gas Chromatography - Flame Ionization Detector
Toluene
108-88-3
575-002 Passive Sampler for Organic Vapor, Anasorb® 747 sorbent   GC-FID — Gas Chromatography - Flame Ionization Detector
Toluene
108-88-3
690-101 Ultra III Passive Sampler, GCB1  or
690-103 Ultra III Passive Sampler, Chromosorb 106  or
690-104 Ultra III Passive Sampler, Tenaz TA   
TD, GC — Thermal Desorption - Gas Chromatography
Toluene
108-88-3
800-01401 Dräger Color Diffusion Tube  
DR — Direct Reading
Toluene
108-88-3
810-122DL Gastec Color Dosimeter Tube  
DR — Direct Reading
1,1,2-Trichloro-1,2,2-trifluoroethane (Freon 113)
76-13-1
575-001 Passive Sampler for Organic Vapor, Charcoal sorbent   GC-FID — Gas Chromatography - Flame Ionization Detector
1,1,1-Trichloroethane (methyl chloroform)
71-55-6
575-001 Passive Sampler for Organic Vapor, Charcoal sorbent   GC-FID — Gas Chromatography - Flame Ionization Detector
1,1,1-Trichloroethane
71-55-6
690-101 Ultra III Passive Sampler, GCB1  or
690-103 Ultra III Passive Sampler, Chromosorb 106   
TD, GC — Thermal Desorption - Gas Chromatography
1,1,2-Trichloroethane
79-00-5
575-001 Passive Sampler for Organic Vapor, Charcoal sorbent   GC-FID — Gas Chromatography - Flame Ionization Detector
1,1,2-Trichloroethane
79-00-5
690-101 Ultra III Passive Sampler, GCB1  or
690-103 Ultra III Passive Sampler, Chromosorb 106  or
690-104 Ultra III Passive Sampler, Tenaz TA   
TD, GC — Thermal Desorption - Gas Chromatography
Trichloroethylene
79-01-6
575-001 Passive Sampler for Organic Vapor, Charcoal sorbent   GC-FID — Gas Chromatography - Flame Ionization Detector
Trichloroethylene
79-01-6
575-002 Passive Sampler for Organic Vapor, Anasorb® 747 sorbent   GC-FID — Gas Chromatography - Flame Ionization Detector
Trichloroethylene
79-01-6
690-101 Ultra III Passive Sampler, GCB1  or
690-103 Ultra III Passive Sampler, Chromosorb 106  or
690-104 Ultra III Passive Sampler, Tenaz TA   
TD, GC — Thermal Desorption - Gas Chromatography
Trichloroethylene
79-01-6
800-01441 Dräger Color Diffusion Tube  
DR — Direct Reading
Trichloroethylene
79-01-6
810-132D Gastec Color Dosimeter Tube  
DR — Direct Reading
1,2,3-Trichloropropane
96-18-4
575-001 Passive Sampler for Organic Vapor, Charcoal sorbent   GC-FID — Gas Chromatography - Flame Ionization Detector
Triethylamine
121-44-8
810-3D Gastec Color Dosimeter Tube  
DR — Direct Reading
Trifluoromethyl benzene (benzotrifluoride; OXSOL 2000)
98-08-8
575-001 Passive Sampler for Organic Vapor, Charcoal sorbent   GC-FID — Gas Chromatography - Flame Ionization Detector
Trifluoromethyl benzene (benzotrifluoride; OXSOL 2000)
98-08-8
575-002 Passive Sampler for Organic Vapor, Anasorb® 747 sorbent   GC-FID — Gas Chromatography - Flame Ionization Detector
Trimethylamine
75-50-3
810-3DL Gastec Color Dosimeter Tube  
DR — Direct Reading
1,2,3-Trimethylbenzene
526-73-8
575-001 Passive Sampler for Organic Vapor, Charcoal sorbent   GC-FID — Gas Chromatography - Flame Ionization Detector
1,2,3-Trimethylbenzene
526-73-8
575-002 Passive Sampler for Organic Vapor, Anasorb® 747 sorbent   GC-FID — Gas Chromatography - Flame Ionization Detector
1,2,3-Trimethylbenzene
526-73-8
690-101 Ultra III Passive Sampler, GCB1  or
690-104 Ultra III Passive Sampler, Tenaz TA   
TD, GC — Thermal Desorption - Gas Chromatography
1,2,4-Trimethylbenzene
95-63-6
575-001 Passive Sampler for Organic Vapor, Charcoal sorbent   GC-FID — Gas Chromatography - Flame Ionization Detector
1,2,4-Trimethylbenzene
95-63-6
575-002 Passive Sampler for Organic Vapor, Anasorb® 747 sorbent   GC-FID — Gas Chromatography - Flame Ionization Detector
1,2,4-Trimethylbenzene
95-63-6
690-101 Ultra III Passive Sampler, GCB1  or
690-104 Ultra III Passive Sampler, Tenaz TA   
TD, GC — Thermal Desorption - Gas Chromatography
1,3,5-Trimethylbenzene (mesitylene)
108-67-8
575-001 Passive Sampler for Organic Vapor, Charcoal sorbent   GC-FID — Gas Chromatography - Flame Ionization Detector
1,3,5-Trimethylbenzene (mesitylene)
108-67-8
575-002 Passive Sampler for Organic Vapor, Anasorb® 747 sorbent   GC-FID — Gas Chromatography - Flame Ionization Detector
1,3,5-Trimethylbenzene (mesitylene)
108-67-8
690-101 Ultra III Passive Sampler, GCB1  or
690-103 Ultra III Passive Sampler, Chromosorb 106  or
690-104 Ultra III Passive Sampler, Tenaz TA   
TD, GC — Thermal Desorption - Gas Chromatography
2,2,4-Trimethylpentane
540-84-1
575-001 Passive Sampler for Organic Vapor, Charcoal sorbent   GC-FID — Gas Chromatography - Flame Ionization Detector

Chemical Hazard Search:
  Enter chemical name in box above

Catalog Number Search:
  Enter the catalog number in box above

CAS Number Search:
  Enter the CAS number in box above

Chemical Hazards by First Letter

A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z

This SKC Air Sampling Guide is a reference only to assist users in finding the method, sampling equipment, and sampling media for a specific compound. This publication is intended for general information only and should not be used as a substitute for reviewing applicable government regulations, equipment operating instructions, or legal standards. Users must consult the appropriate sampling method for the compound of interest before sampling. The sampling parameters shown here are suggestions based on the ranges or volume, flow, and time specified in the methods. It is the responsibility of the analyst performing the sampling and analysis steps to adjust the parameters so that the required detection limits can be obtained. The information contained in this document should not be construed as legal advice or opinion nor as a final authority on legal or regulatory procedures.

  About SKC Terms of Use Privacy Policy Contact Us Site Map Ordering Information
This site was last modified May 23, 2013
SKC Inc.'s Quality Policy is in Compliance with IS0 9001-2008
© Copyright 1995-2013 SKC Inc.