Personal Modular Impactor (PMI)
Highly Efficient Personal PM10, PM2.5, or
PM Coarse Sampling
- Models
available
for PM10, PM2.5, or PM Coarse (10-2.5) sampling
- Use with any constant flow pump at 3 L/min
- Closely follows PM2.5 or PM10 as defined by EPA
- Compact and lightweight — only 2.5 ounces (71
grams)
- Ideal for personal or micro-environmental sampling
- Convenient modular design for easy operation
- Removable filter cassette for easy media changes
- Disposable ready-to-use pre-oiled impaction discs reduce particle bounce for high collection efficiency — no cleaning or greasing
- Convenient clip for mounting sampler in the breathing zone
- PMI PM10 model is easily converted with accessory ring to measure PM Coarse
- PMI PM10 model is suitable for ACGIH® thoracic TLVs®
- Including sulfuric acid and cotton dust as thoracic particulate
matter
SKC Personal Modular Impactors Operating Instructions (PDF)
SKC Personal Modular Impactors Spec. Sheet (PDF)
SKC Personal Modular Impactors Performance Profile (PDF)
Modular Impactors Poster Presentation (PDF)
SKC Personal Modular Impactors
The patented (U.S. Patent No. 7,334,453) SKC
Single-stage Personal Modular Impactors (PMIs) are designed for the
highly efficient collection of PM10, PM2.5, or PM Coarse (10-2.5) .
The samplers are easy to use with a removable filter cassette and pre-oiled
impaction
disc. PMI media changes are as easy as removing the filter cassette
and replacing it with one already loaded with a 37-mm final filter.
The 25-mm pre-oiled impaction disc mounts directly on top of the filter
cassette and reduces particle bounce for high collection efficiency.
A 25-mm filter may be used as an alternate impaction substrate for
optional gravimetric or chemical analysis of particles. The PMI Coarse
model and the Coarse Ring accessory include a second filter cassette
to allow collection of particles sized between 2.5 µm and 10 µm.

Collection Efficiency of PMI 2.5 and PMI 10 Samplers
(Click to enlarge)
About PMI Coarse (PM10-2.5)
When using the PMI Coarse (see Figure 2), air is drawn through a PM10 inlet.
Particles > 10 µm collect on an oiled impaction disc mounted in the
top of the first filter cassette. No filter is loaded inside this cassette.
The air proceeds through a PM2.5 impactor (coarse ring). Particles sized between
10 µm and 2.5 µm (10-2.5 µm) collect on a 25-mm filter placed
in the impaction substrate position in the top of the second filter cassette.
Particles < 2.5 µm collect on the 37-mm final filter inside the second
filter cassette. Filters are sent to a laboratory for gravimetric and chemical
analyses.

Performance Profile
| Flow Rate |
3 L/min for all models |
| 50% Cut-point |
10 µm or 2.5 µm (model dependant) |
| Material |
Inlet: Precision-tooled aluminum |
| Exhaust: PVC |
| Filter Cassette: Delrin® with
stainless steel support screen |
O-ring: Inlet — PTFE
O-ring: Exhaust — BUNA-N
|
| Final Collection Filter |
37-mm filter, select filter material based on application |
| Impaction Substrate |
25-mm pre-oiled, disposable porous plastic disc to reduce particle
bounce or 25-mm filter for optional chemical analysis |
| Analyses |
Gravimetric and chemical |
Dimensions
(without clip) |
Diameter: 2 in (5.1 cm) |
| Height: 1 in (2.6 cm) |
| Weight: 2.5 oz (70.9 gm) |
| Tubing |
1/4-inch ID |
Partner AirChek® XR5000 Pump with PMI
The PMI Samplers may be used with any constant flow sample pump capable of
maintaining a constant 3 L/min flow rate. However, partnering a PMI
Sampler with an AirChek XR5000 Sample Pump creates a highly efficient sampling
system. The compact, lightweight XR5000 pump is ideal for personal sampling.
Ordering information
| Description |
Cat. No. |
Personal Modular
Impactor (PMI) includes impactor and filter cassette
with support screen, requires impaction substrate and collection
media sold separately; see below
|
PM2.5 (gold) |
 |
|
| PM10 (silver) |
 |
|
PM Coarse,
includes 2 filter cassettes and filter retainer |
 |
|
| Recommended Collection
Filters
|
| Quartz Filters, 37 mm, Tissuquartz™,
432 µm thick, pk/25 |
|
PTFE Filters, 37 mm,
2.0-µm pore size, with PMP support ring, pk/50
Back pressure on PTFE filters can vary within the same lot. |
|
PTFE Filters, 37 mm,
1.0-µm pore size, with laminated PTFE support, pk/50
Back pressure on PTFE filters can vary within the same lot.
|
|
| Recommended Impaction
Substrate, required for sampling. Limited shelf-life
|
Pre-oiled Porous Plastic
discs, 25 mm, ready to use, disposable.
A 25-mm filter may be used as an alternative impaction substrate for
optional chemical analysis. |
pk/25 |
|
| pk/50 |
|
| Accessories
|
| PM Coarse Ring includes filter
cassette and retainer, adapts a PMI 10 to a PMI Coarse |
|
| Replacement Filter Cassette |
|
| PMI Cassette Opener |
|
| Forceps, stainless steel, non-serrated
flat tips |
|
| Filter-Keepers, 37
mm, for filter transport, pk/100 |
|
| Filter-Keepers, 37 mm, for filter transport,
pk/10 |
|
| PMI Calibration Adapter |
|
| Replacement PMI Exhaust O-ring, ea |
P32001 |
| Filter Retainer, secures filter
to impaction substrate position on top of cassette. Included
in Cat. No. 225-3512 |
225-354 |
SKC Personal Modular Impactors
Operating Instructions (PDF)
SKC Personal Modular Impactors
Spec. Sheet (PDF)
SKC Personal Modular Impactors
Performance Profile (PDF)
Modular
Impactors Poster Presentation (PDF)
This page was last modified February 19, 2013
|