MiniVac
Air Sampling Canisters for Personal or Area Whole Air
Sampling
- No pump or batteries needed
- Suitable for short-term and personal sampling
- Collect multiple contaminants at unknown concentrations for multiple
analyses
- Available in 400 or 1000-ml volumes
- Ultimate stability for reduced sulfur-containing analytes
- Sulfinert-treated canister and valve available
- 1000-ml canister suitable for collecting VOCs in air according to U.S.
EPA Methods TO-14 and TO-15
- Multi-purpose
- Indoor air sampling
- Personal sampling
- Emergency response
- Soil gas sampling
- Easy-to-use quick-connect fitting for a "no-tool" connection
to samplers and analyzers
- Smaller canisters reduce storage space needs and shipping charges
- Can be cleaned quickly and reused hundreds of times
MiniVac
Air Sampling Canisters Product Data Bulletin (PDF)
MiniVac Canisters
Canisters with a typical volume of six liters have been used extensively
for sampling VOCs (EPA Methods TO-14A and
TO-15). SKC MiniVac® Canisters combine the benefits of larger
canister sampling with small, lightweight 400-ml and 1-L canisters
that can
be placed at a sampling site for area sampling or attached to a
worker's
belt for personal sampling. SKC 400-ml and 1-L stainless steel
MiniVac Canisters are optimized for personal, indoor air, and source
VOC sampling from 1 ppb to 10,000 ppm.
Using MiniVac Canisters
Ensure the canister is certified clean and evacuated. Connect the
canister to a flow controller if time-integrated samples are desired
or simply open it for grab sampling. Attach the canister at a sampling
site or onto a worker's belt and allow it to fill. The canister will
stop filling when it reaches equilibrium with external atmospheric
pressure. Ship the canister with sample to a laboratory
for analysis and subsequent cleaning.
The Sulfinert Difference
The interior of a standard MiniVac Canister is electro-polished
(proprietary process-Summa equivalent) for inertness. For ultimate
stability, use canisters with a Sulfinert-treated interior to collect
and store reduced sulfur-containing analytes.
MiniVac Canister Applications
- Indoor air investigations
- Personal sampling
- Emergency response
- Soil gas sampling
MiniVac Canisters vs Larger-volume Canisters
Small, lightweight MiniVac Canisters complement existing larger
volume canisters. The application determines which volume of canister
to use.
- MiniVac Canisters (400 and 1000 ml) are used
for more concentrated samples such as soil gas.
- 3 and 6-liter canisters are typically used
to collect integrated (TWA) ambient air samples at sampling times
of up to 24 hours.
- 15-liter canisters are used for reference standards.
Canisters Analytical Laboratories
Reference List
Canisters with Quick-connect Stem Fitting
For attachment to samplers and analyzers. Requires quick
connect body fitting when used with a Passive Kit. See accessories.
Ordering Information
| Description |
Cat. No. |
| MiniVac Canister, electro-polished interior,
400 ml, untreated fitting |
228-788 |
| MiniVac Canister, Sulfinert-treated interior, 400
ml, untreated fitting |
228-789 |
| MiniVac Canister, Sulfinert-treated interior,
400 ml, Sulfinert-treated fitting |
228-790 |
| MiniVac Canister, electro-polished interior,
1000 ml, untreated fitting |
228-794 |
| MiniVac Canister, Sulfinert-treated interior,
1000 ml, untreated fitting |
228-795 |
| MiniVac Canister, Sulfinert-treated interior,
1000 ml, Sulfinert-treated fitting |
228-796 |
Canisters with Metal-seated Diaphragm Valve
For small grab samples or connection to a flow controlled system.
Ordering Information
| Description |
Cat. No. |
MiniVac Canister, electro-polished
interior, 400 ml, untreated valve |
228-791 |
MiniVac Canister, Sulfinert-treated interior, 400 ml, untreated valve
|
228-792 |
MiniVac Canister, Sulfinert-treated
interior, 400 ml, Sulfinert-treated valve
|
228-793 |
MiniVac Canister, electro-polished
interior, 1000 ml, untreated valve
|
228-797 |
MiniVac Canister, Sulfinert-treated
interior, 1000 ml, untreated valve
|
228-798 |
MiniVac Canister, Sulfinert-treated
interior, 1000 ml, Sulfinert-treated valve
|
228-799 |
Accessories
Ordering Information
| Description |
Cat. No. |
Quick-connect Stem Fitting for MiniVac,
untreated
|
228-785 |
Quick-connect Stem Fitting for MiniVac,
Sulfinert-treated
|
228-786 |
|
Quick-connect Body Fitting for MiniVac,
untreated, required to connect stem-fitted canisters to a
Passive Kit
|
228-787 |
Passive Kits for TO-Can, SilcoCan, and MiniVac Canisters
Each Passive Kit includes a Veriflo flow controller, critical
orifice, vacuum gauge, 2-µm frit (filter), and sampling inlet. Canisters
are not included.
Ordering Information
Canister
Volume
400 ml
|
Flow
(ml/min) |
Orifice
(in) |
Siltek
Passive Kits |
Stainless Steel Passive Kits |
| Cat. No. |
Cat. No. |
| 8 hour |
0.5-2 |
0.0008 |
228-805 |
228-806 |
| 2 hour |
2-4 |
0.0012 |
228-774 |
228-779 |
| 1 hour |
4-8 |
0.0016 |
228-775 |
228-780 |
| — |
8-20 |
0.0020 |
228-776 |
228-781 |
MiniVac Air Sampling Canisters
Product Data Bulletin (PDF)
For a listing of laboratories that analyze and clean canisters,
see the
Canisters Analytical Laboratories Reference List
SKC offers a full line of canisters in 1, 3, 6, and 15-liter volumes.
Combine canisters with a passive kit for easy time-integrated sampling without
a pump for compounds listed in EPA Methods TO-14A and TO-15.
Contact SKC today
for information on TO-Can and SilcoCan Canisters and fittings.
This page was last modified April 11, 2008
|