HAZ-SCANNER EPAS
|
||||||||||||||||||||||||||||||||||||||||||||
![]() |
Configure an EPAS for Up to 14 Simultaneous Measurements The standard HAZ-SCANNER EPAS includes the monitor (calibrated for ambient air applications) with sensors/meters for PM10 or TSP, VOCs, temperature, humidity, and wind speed/direction in a NEMA 4 enclosure, acid gas scrubber, internal battery, universal 110-240 V AC battery charger, software, cables, and CD with instructions. Configure the monitor with additional sensors/meters — up
to 4 optional plug and play sensors and/or up to 4 EPAS-specific
meters (listed below). See the HAZ-SCANNER
EPAS Product Data Bulletin (PDF) for specifications. Specify sensors and meters
when ordering.
HAZ-SCANNER Wireless EPAS Applications
|
| Haz-SCANNER EPAS shown with optional solar panels | |

Measure up to 14 critical air parameters with HAZ-SCANNER
EPAS.
Configure an EPAS for Up to 14 Simultaneous Measurements
The standard HAZ-SCANNER EPAS includes the monitor (calibrated for
ambient air applications) with sensors/meters for PM10 or TSP, NO2, CO,
temperature, and relative humidity in a NEMA 4 enclosure,
acid gas scrubber, internal battery, universal 110-240 V AC battery
charger, software, cables, and CD with instructions.
Configure the monitor with additional sensors/meters — up to 4 optional plug and play sensors and/or up to 4 EPAS-specific meters (listed below). See the HAZ-SCANNER EPAS Product Data Bulletin (PDF) for specifications. Specify sensors and meters when ordering.
Standard sensors/meters included:Contact SKC to build an EPAS with available sensors/meters/ calibration for your application!
Performance Profile
The HAZ-SCANNER EPAS is optimized for ambient air quality applications;
custom calibration for specific ranges or applications is available upon request.
Build the station you need for your application.
HAZ-SCANNER EPAS Instrument Specifications
| Display | LCD real time |
| Operation | 4-key splash-proof membrane switch |
| Power | 12-V Absorption Glass Mat (AGM) rechargeable battery or 100-240 V AC |
| Operating Time | 20 hrs (battery), continuous (AC or optional solar panel) |
| Display Measurements | Max, Min, TWA, STEL |
| Recording Time | 1 sec to 21 weeks |
| Sampling Rate | 1 sec, 1 min, 10 min, 1 hr, adjustable |
| Data Storage | 454,545 data points |
| Flow Range | 1.0 to 3.0 L/min |
| Digital Output | RS-232 (PC), RS-423 (Mac) |
| Software | PC or Mac |
| Dimensions (weather-proof case) | 6 x 14 x 10 in (15.2 x 35.6 x 25.4 cm) |
| Weight | 12 lbs (5.4 kg) |
| Operating Temperature | -4 to 140 F (-20 to 60 C) |
| Storage Temperature | -40 to 140 F (-40 to 60 C) |
| Humidity | 95% non-condensing (use inlet heater) |
| Wireless Radio Modem | 900 MHz (U.S.), 868 MHz (Euro) up to 5 miles - line of sight (optional) |
| Auxiliary Analog Input | 0 to 2.5 VDC (1 channel for alternative meter) |
| * | Note: | All methane and non-methane hydrocarbon sensors are not approved for intrinsically safe applications. Do not use in explosive gas environments. |
Ordering Information
The HAZ-SCANNER EPAS wireless environmental perimeter air
station is a custom item. Contact SKC to build your own station.
HAZ-SCANNER EPAS Product Data Bulletin (PDF)
HAZ-SCANNER EPAS Wireless Environmental Perimeter Air Station Video
Haz-Scanner EPAS User Manual (PDF)
Haz-Scanner Quick Start Guide (PDF)
| About SKC | Terms of Use | Privacy Policy | Contact Us | Site Map | Ordering Information |