Leland Legacy 5-Pack Pump Kit w/Single Chargers

Part Number:

100-3002K5A

- +
Overview
Leland Legacy® 5-Pack Pump Kit includes 5 pumps with Li-Ion battery, (5) 100-240 V single-station chargers with interchangeable plugs, DataTrac® Software cable (USB), and carry case.
The personal-size Leland Legacy air sampling pump offers flows from 5 to 15 L/min, PC-programmability, and up to 24-hour run times for personal or area sampling of low-level contaminants. The pump is ideal for use with impactors, low-volume PUF tubes, filter cassettes, and spore traps. The Leland Legacy air sampling pump is CE marked. It is not UL Listed for intrinsic safety.
Attributes
Flow Rate5 to 15 L/min
Touch Screen OperationNo
Battery Type (Power)Li-ion
Approx. Run Time24+ Hours at 10 L/min
ConnectivityWith included USB Cable
PC CompatibleYes
ProgrammableYes
Compensates for Changes in Atmospheric PressureYes
Compensates for Changes in TemperatureYes
Constant FlowYes
Constant Pressure ModeNo
Automatic Flow Rate VerificationYes
Intrinsic SafetyNo
CE MarkedYes
UKCA MarkedYes
 

Performance Profile

Flow Range5 to 15 L/min
Flow Control SystemClosed loop with internal flow sensor
Compensation Range15 L/min at 5 inches water back pressure
10 L/min at 12 inches water back pressure
 5 L/min at 20 inches water back pressure
AccuracyFlow Rate: ± 5% of set-point after flow rate verification to desired flow
Timing: 1 min/mo at 25 C
Atmospheric Pressure: ± 0.3 in Hg
Flow FaultIf the pump is unable to compensate for > 15 seconds due to excessive back pressure, a flow fault icon displays and flashes, the pump enters Hold mode, and the pump retains historical data. Auto restart is attempted every 20 seconds up to 10 times. Adjustable with DataTrac for Leland Legacy software
Flow ControlAn internal isothermal flow sensor measures flow directly and continuously. Sensor readings are used in a flow monitoring algorithm to maintain calibrated volumetric flow. In addition, built-in atmospheric temperature and pressure sensors provide readings to correct volumetric flow for these parameters when they vary from point of flow rate verification.
TubingRequires 3/8-inch ID tubing
DisplayLCD, displays pump serial number, pump software revision level, flow rate, volume, temperature, atmospheric pressure, time of day, run time, and pump status, i.e., hold and run as well as Setup information
Volume DisplayContinually updated, based on corrected flow rate multiplied by sampling time. When volume exceeds 99,999 liters, the pump will continue to run normally but an O_FLO error will appear on the LCD.
Time DisplayTime of day in hours and minutes (12 or 24-hour clock) with AM and PM indicators
Timer Display Range1 to 99999 minutes (69 days). If the run time exceeds 69 days, the timer display rolls over.
Operating Temperature Range32 to 104 F (0 to 40 C)
Protect sample pump from weather when in use outdoors.
AltitudeThe pump can apply correction to volumetric flow during sampling for weather-related or altitude variations from the atmospheric pressure established at flow rate verification up to at least 7500 feet (2286 meters) above and 5000 feet (1524 meters) below sea level.
Typical Run Time

24+ hours:

  • Sioutas Impactor at 9 L/min (approximately 13 inches water back pressure)
  • Low-volume PUF Tube at 5 L/min
  • DPS Sampler (PM2.5 or PM10) at 10 L/min
  • For extended run times, the pump may be operated while attached to the approved charger.
  • 8 L/min Respirable PPI
Results obtained using a new pump and new fully charged battery. Pump and battery performance may vary.
Noise Level62.5 dBA — pump without case
52 dBA — pump housed in noise-reducing case (optional accessory Cat. No. 224-89) measured 3 ft (1 m) from pump operating at 10 L/min without media
User-adjustable ValuesSample run time, flow rate verification, clock display, flow rate, time of day, delayed start, and temperature and atmospheric pressure display
Recorded ValuesStart date and time, stop date and time, total sample time, flow rate, sample volume, temperature, atmospheric pressure, and pump mode transitions
Adjustable Logging IntervalRecords pump history from 3 seconds (15.4 min of data) up to 8 hours (over 102 days of data) depending on setting. Option available when using DataTrac Software
Power SupplyBattery: removable, rechargeable lithium-ion (Li-Ion) battery pack 7.4 V x 12-Ah capacity, 89 Wh.
Charger/AC adapter: input voltage 100-240 V AC
Battery Recharge Time (with SKC-approved charger)15 hrs
Temperature: Charging32 to 113 F (0 to 45 C)
Temperature: Storage-4 to 95 F (-20 to 35 C)
Size8 x 3.9 x 2.6 in (20 x 10 x 7 cm)
Weight36 oz (1 kg)
CaseThermoplastic with soft rubber overmolding
RFI/EMI ShieldingCE marked