MultiRAE Lite, Pumped
Part Number:
730-MAB3B8C102E020
Overview
MultiRAE Lite, pumped, CO2/LEL/CO/O2 non-wireless. RAE No. MAB3-B8C102E-020
Part Number:
730-MAB3B8C102E020
| Manufacturer | Honeywell RAE Systems |
|---|---|
| Type | Portable |
| Number of Sensors | 1 to 6 |
| PID | No |
| Chemical Hazard | Carbon Dioxide, LEL (Combustible Gas), Carbon Monoxide, Oxygen |
| Replaceable Sensor | Yes |
| Datalogging | Yes |
| Intrinsic Safety | Yes |
| CE Marked | Yes |
Performance Profile
Profile/Option Availability | MultiRAE Lite 6 Gas |
| Main Application(s) | 1 to 6 Gas Personal Protection Monitor |
| Gamma Radiation Sensor Option | — |
| ppb PID Option (10.6 eV; 0.01 to 2000 ppm; 10-ppb resolution) | — |
| High-end ppm PID Option (10.6 eV; 0.1 to 5000 ppm; 0.1-ppm resolution) | — |
| ppm PID Option (10.6 eV; 1 to 1000 ppm; 1-ppm resolution) | Yes* |
| 9.8 eV PID Option (1 to 1000 ppm, benzene; 0.1-ppm resolution) | — |
| 25 Electrochemical Sensors Available | Yes |
| Catalytic % LEL Sensor Option | Yes |
| Combustible NDIR Option (% LEL or % Vol) | Yes |
| Carbon Dioxide NDIR Sensor Option | Yes |
| Wireless Option | Yes |
| MIL-STD-810F Compliant | — |
Profile/Option Availability | MultiRAE 6 Gas |
| Main Application(s) | 1 to 6 Gas Monitor with Advanced VOC Detection |
| Gamma Radiation Sensor Option | — |
| ppb PID Option (10.6 eV; 0.01 to 2000 ppm; 10-ppb resolution) | — |
| High-end ppm PID Option (10.6 eV; 0.1 to 5000 ppm; 0.1-ppm resolution) | Yes |
| ppm PID Option (10.6 eV; 1 to 1000 ppm; 1-ppm resolution) | — |
| 9.8 eV PID Option (1 to 1000 ppm, benzene; 0.1-ppm resolution) | — |
| 25 Electrochemical Sensors Available | Yes |
| Catalytic % LEL Sensor Option | Yes |
| Combustible NDIR Option (% LEL or % Vol) | Yes |
| Carbon Dioxide NDIR Sensor Option | Yes |
| Wireless Option | Yes |
| MIL-STD-810F Compliant | Yes |
Profile/Option Availability | MultiRAE Pro 6 Threat |
| Main Application(s) | Multi-threat Monitor for Radiation and Chemical Detection |
| Gamma Radiation Sensor Option | Yes |
| ppb PID Option (10.6 eV; 0.01 to 2000 ppm; 10-ppb resolution) | Yes |
| High-end ppm PID Option (10.6 eV; 0.1 to 5000 ppm; 0.1-ppm resolution) | Yes |
| ppm PID Option (10.6 eV; 1 to 1000 ppm; 1-ppm resolution) | — |
| 9.8 eV PID Option (1 to 1000 ppm, benzene; 0.1-ppm resolution) | Yes |
| 25 Electrochemical Sensors Available | Yes |
| Catalytic % LEL Sensor Option | Yes |
| Combustible NDIR Option (% LEL or % Vol) | Yes |
| Carbon Dioxide NDIR Sensor Option | Yes |
| Wireless Option | Yes |
| MIL-STD-810F Compliant | Yes |