SKC HSE Sampling Guide for Dibutyl hydrogen phosphate

SKC HSE Sampling Guide for Dibutyl hydrogen phosphate
Chemical Information
Dibutyl hydrogen phosphate
107-66-4
GC-FPD
NIOSH 5017
Sampling Parameters

TWA 1 ppm (8.7 mg/m3)
C/STEL 2 ppm (17 mg/m3)

240

2000

2

SKC Sampling Equipment

Filter:
  1. Filter, PTFE w/ Laminated PP Support, 1.00 µm, 37mm, 100Pk
    Part Number: 225-17-01
    $249.95 /PK
    PTFE Filter, 1.0 µm, 37-mm, on polypropylene support.
Filter Cassette:
  1. Cassette, Blank, SureSeal™, Leak Free, 2-Piece, 37mm, Clear Styrene, 10Pk
    Part Number: 225-2LF
    $19.95 /PK
    SureSeal Filter Cassette Blank, 2 sections, 37-mm, clear styrene filter cassette blank, leak free to ensure high quality sampling results.
Filter Cassette and Cyclone Holder:
  1. Filter Cassette Holder
    Part Number: 225-1
    $33.00 /EA
    Filter Cassette Holder, accommodates two or three-piece 25 or 37-mm cassettes with or without a cyclone, clips to a worker's collar; includes 3 feet of 1/4-inch ID Tygon tubing and 25-mm adapter ring.

This SKC Air Sampling Guide is a reference only to assist users in finding the method, sampling equipment, and sampling media for a specific compound. This publication is intended for general information only and should not be used as a substitute for reviewing applicable government regulations, equipment operating instructions, or legal standards. Users must consult the appropriate sampling method for the compound of interest before sampling. The sampling parameters shown here are suggestions based on the ranges or volume, flow, and time specified in the methods. It is the responsibility of the analyst performing the sampling and analysis steps to adjust the parameters so that the required detection limits can be obtained. The information contained in this document should not be construed as legal advice or opinion nor as a final authority on legal or regulatory procedures.