SKC HSE Sampling Guide for Iodoform

SKC HSE Sampling Guide for Iodoform
Chemical Information
Iodoform
75-47-8
GC-ECD
OSHA CSI
Sampling Parameters

TWA 0.6 ppm (9.8 mg/m3)
C/STEL 1 ppm (16 mg/m3)

10

100

100 min

SKC Sampling Equipment

Filter in Preloaded Cassette:
  1. Filter Cassette, Glass Fiber Type A/E, w/Support Pad, 37mm, 3-Piece Clear Styrene Traditional Style, Banded, 50Pk
    Part Number: 225-706
    $74.95 /PK
    Glass Fiber Filter, Type A/E, 37-mm, preloaded in a 3-piece clear plastic cassette, pre-banded.
Filter Cassette and Cyclone Holder:
  1. Filter Cassette Holder
    Part Number: 225-1
    $33.00 /EA
    Filter Cassette Holder, accommodates two or three-piece 25 or 37-mm cassettes with or without a cyclone, clips to a worker's collar; includes 3 feet of 1/4-inch ID Tygon tubing and 25-mm adapter ring.
Sorbent Tube:
  1. Sorbent Tube, XAD-4, 7 x 70-mm size, 2 sections, 80/40 mg sorbent, 20/40 mesh, 50Pk
    Part Number: 226-93
    $156.00 /PK
    Sorbent Tube, XAD-4, 7 x 70-mm size, 2 sections, 80/40 mg sorbent, 20/40 mesh. Tube Ends: Glass Sealed Separators: Glass Wool/Glass Wool/Glass Wool

This SKC Air Sampling Guide is a reference only to assist users in finding the method, sampling equipment, and sampling media for a specific compound. This publication is intended for general information only and should not be used as a substitute for reviewing applicable government regulations, equipment operating instructions, or legal standards. Users must consult the appropriate sampling method for the compound of interest before sampling. The sampling parameters shown here are suggestions based on the ranges or volume, flow, and time specified in the methods. It is the responsibility of the analyst performing the sampling and analysis steps to adjust the parameters so that the required detection limits can be obtained. The information contained in this document should not be construed as legal advice or opinion nor as a final authority on legal or regulatory procedures.