SKC HSE Sampling Guide for Malathion

SKC HSE Sampling Guide for Malathion
Chemical Information
Malathion
121-75-5
GC-FPD
OSHA 62
Sampling Parameters

TWA 10 mg/m3

60

1000

1

SKC Sampling Equipment

Sorbent Tube:
  1. OVS Sorbent Tube, XAD-2 sorbent w/Glass Fiber Filter, 13 to 8 x 75-mm size, 2 sections, 270/140 mg, 20/60 mesh, 10Pk
    Part Number: 226-30-16
    $172.00 /PK
    OVS Sorbent Tube, XAD-2 sorbent, 20/60 mesh, 2 sections, 270/140 mg, and glass fiber filter inside a 13 †’ 7 x 60-mm size glass tube; for pesticides (OSHA 62, 63, 67, 70, 74, CSI) and organotin compounds (OSHA CSI). Tube Ends: Glass Open Separators: PTFE Ring/Glass Fiber Filter/Foam/Foam

This SKC Air Sampling Guide is a reference only to assist users in finding the method, sampling equipment, and sampling media for a specific compound. This publication is intended for general information only and should not be used as a substitute for reviewing applicable government regulations, equipment operating instructions, or legal standards. Users must consult the appropriate sampling method for the compound of interest before sampling. The sampling parameters shown here are suggestions based on the ranges or volume, flow, and time specified in the methods. It is the responsibility of the analyst performing the sampling and analysis steps to adjust the parameters so that the required detection limits can be obtained. The information contained in this document should not be construed as legal advice or opinion nor as a final authority on legal or regulatory procedures.