SKC OSHA / NIOSH Sampling Guide for Chlordane

SKC OSHA / NIOSH Sampling Guide for Chlordane
Chemical Information
Chlordane
57-74-9
GC-ECD
0.1µg/sample
Sampling Parameters

TWA 0.5 mg/m3
C/STEL

10 @0.5mg/m3 - 200 L

500 - 1000 ml/min

varies

SKC Sampling Equipment

Sorbent Tube:
  1. Sorbent Tube, Chromosorb 102, 8 x 110-mm size, 2 sections, 100/50 mg sorbent, 20/40 mesh, 50Pk
    Part Number: 226-107
    $427.00 /PK
    Sorbent Tube, Chromosorb-102, 8 x 110-mm size, 2 sections, 100/50 mg sorbent, 20/40 mesh. Tube Ends: Glass Sealed Separators: Glass Wool/Glass Wool/Glass Wool
Filter:
  1. Filter, MCE w/Support Pad, 0.80 µm, 37mm, 100Pk
    Part Number: 225-5
    $59.95 /PK
    MCE Filter, 0.8 µm, 37-mm, support pad included.
Filter Cassette:
  1. Cassette, Blank, SureSeal™, Leak Free, 2-Piece, 37mm, Clear Styrene, 10Pk
    Part Number: 225-2LF
    $19.95 /PK
    SureSeal Filter Cassette Blank, 2 sections, 37-mm, clear styrene filter cassette blank, leak free to ensure high quality sampling results.
Screen:
  1. Support Screen, Stainless Steel, Wide Mesh, 37mm
    Part Number: 225-26
    $15.95 /EA
    Support Screen, 37-mm, stainless steel, wide mesh.
Filter Cassette and Cyclone Holder:
  1. Filter Cassette Holder
    Part Number: 225-1
    $33.00 /EA
    Filter Cassette Holder, accommodates two or three-piece 25 or 37-mm cassettes with or without a cyclone, clips to a worker's collar; includes 3 feet of 1/4-inch ID Tygon tubing and 25-mm adapter ring.
Pumps:
  1. AirChek TOUCH Pump
    Part Number: 220-5000TC
    $1,208.00 /EA
    AirChek® TOUCH AirChek Pump with Li-Ion battery pack and screwdriver set. Requires charging cradle and power supply. Connectivity to PC requires 877-93. Low flows from 5 to 500 ml/min require a low flow kit. AirChek TOUCH pumps contain Li-Ion batteries and are subject to special shipping regulations. AirChek TOUCH requires ¼-inch ID tubing.

This SKC Air Sampling Guide is a reference only to assist users in finding the method, sampling equipment, and sampling media for a specific compound. This publication is intended for general information only and should not be used as a substitute for reviewing applicable government regulations, equipment operating instructions, or legal standards. Users must consult the appropriate sampling method for the compound of interest before sampling. The sampling parameters shown here are suggestions based on the ranges or volume, flow, and time specified in the methods. It is the responsibility of the analyst performing the sampling and analysis steps to adjust the parameters so that the required detection limits can be obtained. The information contained in this document should not be construed as legal advice or opinion nor as a final authority on legal or regulatory procedures.