SKC OSHA / NIOSH Sampling Guide for Nitrobenzene

SKC OSHA / NIOSH Sampling Guide for Nitrobenzene
Chemical Information
Nitrobenzene
98-95-3
GC-FID
1 µg/sample
Sampling Parameters

TWA 1 ppm
C/STEL

5 - 50 L

200 ml/min

varies

SKC Sampling Equipment

Coated Filter in Preloaded Cassette:
  1. Coated Filter Cassette, Glass Fiber AE coated w/Sulfuric Acid, w/o Support Pad, 37mm, 3-Piece Traditional Style Styrene Cassette, Banded, 10Pk
    Part Number: 225-9004
    $123.00 /PK
    Coated Filters, 2 Glass fiber filters coated with sulfuric acid, preloaded in a 37-mm cassette, for sampling 4-aminobiphenyl, aniline (also requires sorbent tube Cat. No. 226-15), benzidine, o-dianisidine, 3,3'-dicholorobenzidine, diphenylamine, for sampling n-isopropylaniline, 4,4-methylene bis (2-chloroaniline) (MOCA), 4,4-methylenedianiline, 1-naphthylamine, 2-napththylamine, nitrobenzene (also requires Sorbent Tube Cat. No. 226-15), phenylenediamine (o-, m-, p-), 2,4-toluenediamine, 2,6-toluenediamine, o-tolidine, o-toluidine (also requires Sorbent Tube Cat. No. 226-15), toluidine (o-, m-, p-), m-xylenediamine (m-XDA, p-XDA).
Sorbent Tube:
  1. Sorbent Tube, Silica Gel, 8 x 110-mm size, 2 sections, 520/260 mg sorbent, 20/40 mesh, 50Pk
    Part Number: 226-15
    $122.00 /PK
    Sorbent Tube, Silica Gel, 8 x 110-mm size, 2 sections, 520/260 mg sorbent, 20/40 mesh. Tube Ends: Glass Sealed Separators: Glass Wool/Glass Wool/Foam
Pumps:
  1. Pocket Pump TOUCH Pump
    Part Number: 220-1000TC
    $806.00 /EA
    Pocket Pump® TOUCH with Li-Ion battery and screwdriver. Requires charger. Requires 877-94 to use Bluetooth with PC.

This SKC Air Sampling Guide is a reference only to assist users in finding the method, sampling equipment, and sampling media for a specific compound. This publication is intended for general information only and should not be used as a substitute for reviewing applicable government regulations, equipment operating instructions, or legal standards. Users must consult the appropriate sampling method for the compound of interest before sampling. The sampling parameters shown here are suggestions based on the ranges or volume, flow, and time specified in the methods. It is the responsibility of the analyst performing the sampling and analysis steps to adjust the parameters so that the required detection limits can be obtained. The information contained in this document should not be construed as legal advice or opinion nor as a final authority on legal or regulatory procedures.