SKC OSHA / NIOSH Sampling Guide for NewNitrogen dioxide

SKC OSHA / NIOSH Sampling Guide for NewNitrogen dioxide
Chemical Information
Nitrogen dioxide
10102-44-0
IC
0.25ug NO2/3ml
Sampling Parameters

TWA
C/STEL 1 ppm(NO2)


3 L


200 ml/min


15 min

Important Information
* Modified method;Calculations are different than those listed in OSHA ID-182; see appropriate research report; 226-40A tube see report publication 1985; 226-182 tube see report publication RDP0002.

SKC Sampling Equipment

Sorbent Tube:
  1. Sorbent Tube, Molecular Sieve, 3 Tubes, Tube A: 7 x 70-mm, Molecular Sieve treated w/Triethanolamine (TEA) 400 mg sorbent; Tube B: 7 x 110-mm, Treated Silica Gel (Oxidizer) 400 mg sorbent; Tube C: 7 x 70-mm, Molecular Sieve treated w/Triethanolamine (TEA)
    Part Number: 226-40A
    $187.00 /PK
    Sorbent Tube, multiple-tube train Tube 1: 7 x 70 mm, contains 400 mg Molecular Sieve treated with triethanolamine (TEA). Collects NO2; Tube 2: 7 x 110 mm, contains 400 mg treated silica gel (oxidizer). Converts NO to NO2; Tube 3: 7 x 70 mm, contains 600 mg Molecular Sieve treated with triethanolamine (TEA). Replaces 226-40. Tube Ends: Glass Sealed Separators: Glass Wool/Glass Wool
  2. Sorbent Tube, Molecular Sieve treated w/Triethanolamine/Molecular Sieve treated w/Triethanolamine/Oxidizer, 10 x 110-mm size, 3 sections, 400/400/600 mg sorbent, 20/40 mesh, 50Pk
    Part Number: 226-182
    $544.00 /PK
    Sorbent Tube, Molecular Sieve, for nitric oxide and nitrogen dioxide, contains all components of Cat. No. 226-40A tube, set in one tube, 10 x 110-mm size, 3-section tube, 2 sections molecular sieve coated with triethanolamine and 1 section of oxidizer, 400/400/600 mg sorbent, 20/40 mesh. Tube Ends: Glass Sealed Separators: Glass Wool/Glass Wool/Glass Wool/Glass Wool
  3. Sorbent Tube, Molecular Sieve treated w/Triethanolamine/Molecular Sieve treated w/Triethanolamine/Oxidizer, 10 x 110-mm size, 3 sections, 400/400/600 mg sorbent, 20/40 mesh, 10Pk
    Part Number: 226-182A
    $122.00 /PK
    Sorbent Tube, Molecular Sieve, for nitric oxide and nitrogen dioxide, contains all components of Cat. No. 226-40A tube, set in one tube, 10 x 110-mm size, 3-section tube, 2 sections molecular sieve coated with triethanolamine and 1 section of oxidizer, 400/400/600 mg sorbent, 20/40 mesh. Tube Ends: Glass Sealed Separators: Glass Wool/Glass Wool/Glass Wool/Glass Wool
  4. Sorbent Tube, Molecular Sieve treated w/Triethanolamine, 7 x 110-mm size, 2 sections, 400/200 mg sorbent, 20/40 mesh, 50Pk
    Part Number: 226-40-02
    $337.00 /PK
    Sorbent Tube, Molecular Sieve (triethanolamine), 7 x 110-mm size, 2 sections, 400/200 mg sorbent, 20/40 mesh. Tube Ends: Glass Sealed Separators: Glass Wool/Glass Wool/Glass Wool
Pumps:
  1. Pocket Pump TOUCH Pump
    Part Number: 220-1000TC
    $806.00 /EA
    Pocket Pump® TOUCH with Li-Ion battery and screwdriver. Requires charger. Requires 877-94 to use Bluetooth with PC.

This SKC Air Sampling Guide is a reference only to assist users in finding the method, sampling equipment, and sampling media for a specific compound. This publication is intended for general information only and should not be used as a substitute for reviewing applicable government regulations, equipment operating instructions, or legal standards. Users must consult the appropriate sampling method for the compound of interest before sampling. The sampling parameters shown here are suggestions based on the ranges or volume, flow, and time specified in the methods. It is the responsibility of the analyst performing the sampling and analysis steps to adjust the parameters so that the required detection limits can be obtained. The information contained in this document should not be construed as legal advice or opinion nor as a final authority on legal or regulatory procedures.