SKC OSHA / NIOSH Sampling Guide for N-Phenyl-2-naphthylamine

SKC OSHA / NIOSH Sampling Guide for N-Phenyl-2-naphthylamine
Chemical Information
Phenyl-2-naphthylamine
135-88-6
HPLC-FD
32.5 pg/injection
Sampling Parameters

TWA
C/STEL

240 L

1000 ml/min

4 hr

Important Information
Use two 225-703 Filters
Filters must be chemically treated before use. Refer to the method for details.

SKC Sampling Equipment

Filter:
  1. Filter, Glass Fiber Extra Thick, w/o Support Pad, 1.00 µm, 25mm, 100Pk
    Part Number: 225-703
    $44.95 /PK
    Glass Fiber Filter, 1.0 µm, 25-mm, no support pad included, acrylic binder, 50 mil extra thick.
Filter Cassette:
  1. Cassette, Blank, 3-Piece, 25mm, Black Polypropylene Conductive w/2 inch Spacer, 50Pk
    Part Number: 225-3-23
    $79.95 /PK
    Polypropylene Cassette Blank, 3 sections, 25-mm, carbon-filled, black, conductive, with cowl, tapered-end style for PCM analysis, for reducing sample loss due to electrostatic effects; required for asbestos sampling for reducing sample loss due to electrostatic effects; required for asbestos sampling.
Filter Cassette and Cyclone Holder:
  1. Filter Cassette Holder
    Part Number: 225-1
    $33.00 /EA
    Filter Cassette Holder, accommodates two or three-piece 25 or 37-mm cassettes with or without a cyclone, clips to a worker's collar; includes 3 feet of 1/4-inch ID Tygon tubing and 25-mm adapter ring.
Pumps:
  1. AirChek TOUCH Pump
    Part Number: 220-5000TC
    $1,208.00 /EA
    AirChek® TOUCH AirChek Pump with Li-Ion battery pack and screwdriver set. Requires charging cradle and power supply. Connectivity to PC requires 877-93. Low flows from 5 to 500 ml/min require a low flow kit. AirChek TOUCH pumps contain Li-Ion batteries and are subject to special shipping regulations. AirChek TOUCH requires ¼-inch ID tubing.

This SKC Air Sampling Guide is a reference only to assist users in finding the method, sampling equipment, and sampling media for a specific compound. This publication is intended for general information only and should not be used as a substitute for reviewing applicable government regulations, equipment operating instructions, or legal standards. Users must consult the appropriate sampling method for the compound of interest before sampling. The sampling parameters shown here are suggestions based on the ranges or volume, flow, and time specified in the methods. It is the responsibility of the analyst performing the sampling and analysis steps to adjust the parameters so that the required detection limits can be obtained. The information contained in this document should not be construed as legal advice or opinion nor as a final authority on legal or regulatory procedures.