SKC OSHA / NIOSH Sampling Guide for Thiobencarb (Organonitrogen Pesticides)

SKC OSHA / NIOSH Sampling Guide for Thiobencarb (Organonitrogen Pesticides)
Chemical Information
Thiobencarb (Organonitrogen Pesticides)
28249-77-6
HPLC-UV
0.6 µg/sample
Sampling Parameters

TWA
C/STEL

6 - 480 L

100 - 1000 ml/min

varies

Important Information
Tube 226-58 is specified by the method. Tube 226-30-16 is noted in the method as having equivalent desorption efficiencies for organonitrogen pesticides.

SKC Sampling Equipment

Sorbent Tube:
  1. OVS Sorbent Tube, XAD-2 sorbent w/Quartz Filter, 13 to 8 x 75-mm size, 2 sections, 270/140 mg, 20/60 mesh, 10Pk
    Part Number: 226-58
    $206.00 /PK
    OVS Sorbent Tube, XAD-2 sorbent, 20/60 mesh, 2 sections, 270/140 mg, and quartz filter inside a 13➞8 x 75-mm size glass tube; for pesticides, organophosphorus (NIOSH 5600, 5601, 5602). Tube Ends: Glass Open Separators: PTFE Ring/Quartz Filter/Foam/Foam
  2. OVS Sorbent Tube, XAD-2 sorbent w/Glass Fiber Filter, 13 to 8 x 75-mm size, 2 sections, 270/140 mg, 20/60 mesh, 10Pk
    Part Number: 226-30-16
    $172.00 /PK
    OVS Sorbent Tube, XAD-2 sorbent, 20/60 mesh, 2 sections, 270/140 mg, and glass fiber filter inside a 13 †’ 7 x 60-mm size glass tube; for pesticides (OSHA 62, 63, 67, 70, 74, CSI) and organotin compounds (OSHA CSI). Tube Ends: Glass Open Separators: PTFE Ring/Glass Fiber Filter/Foam/Foam
Pumps:
  1. AirChek TOUCH Pump
    Part Number: 220-5000TC
    $1,208.00 /EA
    AirChek® TOUCH AirChek Pump with Li-Ion battery pack and screwdriver set. Requires charging cradle and power supply. Connectivity to PC requires 877-93. Low flows from 5 to 500 ml/min require a low flow kit. AirChek TOUCH pumps contain Li-Ion batteries and are subject to special shipping regulations. AirChek TOUCH requires ¼-inch ID tubing.

This SKC Air Sampling Guide is a reference only to assist users in finding the method, sampling equipment, and sampling media for a specific compound. This publication is intended for general information only and should not be used as a substitute for reviewing applicable government regulations, equipment operating instructions, or legal standards. Users must consult the appropriate sampling method for the compound of interest before sampling. The sampling parameters shown here are suggestions based on the ranges or volume, flow, and time specified in the methods. It is the responsibility of the analyst performing the sampling and analysis steps to adjust the parameters so that the required detection limits can be obtained. The information contained in this document should not be construed as legal advice or opinion nor as a final authority on legal or regulatory procedures.