SKC OSHA / NIOSH Sampling Guide for Benzoalphapyrene

SKC OSHA / NIOSH Sampling Guide for Benzoalphapyrene
Chemical Information
Benzoalphapyrene
50-32-8
GR & HPLC-FD, or GR & HPLC-UV
0.175 ng/injection. Benzene-soluble fraction 6.0 µg/sample
Sampling Parameters

TWA 0.2 mg/m3
C/STEL

960 L

2000 ml/min

8 hr

Important Information
The filter must be transferred to a separate vial after sampling and the vial must be sealed with a PTFE-lined cap. Protect samples from direct sunlight

SKC Sampling Equipment

Filter:
  1. Filter, Glass Fiber Type A/E, w/o Support Pad 310 to 350 µm thick, 1.00 µm, 37mm, 500Pk
    Part Number: 225-7
    $129.95 /PK
    Glass Fiber Filter, Type A/E, 1.0 µm, 37-mm, no support pad included, 310 to 350 µm thick, binder-free.
Filter Cassette:
  1. Cassette, Blank, SureSeal™, Leak Free, 2-Piece, 37mm, Clear Styrene, 10Pk
    Part Number: 225-2LF
    $19.95 /PK
    SureSeal Filter Cassette Blank, 2 sections, 37-mm, clear styrene filter cassette blank, leak free to ensure high quality sampling results.
Filter Cassette and Cyclone Holder:
  1. Filter Cassette Holder
    Part Number: 225-1
    $33.00 /EA
    Filter Cassette Holder, accommodates two or three-piece 25 or 37-mm cassettes with or without a cyclone, clips to a worker's collar; includes 3 feet of 1/4-inch ID Tygon tubing and 25-mm adapter ring.
Pumps:
  1. AirChek TOUCH Pump
    Part Number: 220-5000TC
    $1,208.00 /EA
    AirChek® TOUCH AirChek Pump with Li-Ion battery pack and screwdriver set. Requires charging cradle and power supply. Connectivity to PC requires 877-93. Low flows from 5 to 500 ml/min require a low flow kit. AirChek TOUCH pumps contain Li-Ion batteries and are subject to special shipping regulations. AirChek TOUCH requires ¼-inch ID tubing.

This SKC Air Sampling Guide is a reference only to assist users in finding the method, sampling equipment, and sampling media for a specific compound. This publication is intended for general information only and should not be used as a substitute for reviewing applicable government regulations, equipment operating instructions, or legal standards. Users must consult the appropriate sampling method for the compound of interest before sampling. The sampling parameters shown here are suggestions based on the ranges or volume, flow, and time specified in the methods. It is the responsibility of the analyst performing the sampling and analysis steps to adjust the parameters so that the required detection limits can be obtained. The information contained in this document should not be construed as legal advice or opinion nor as a final authority on legal or regulatory procedures.