Search Results for: ‘First Letter A’

Search Results for: ‘First Letter A’

ChemicalCAS No.Method No.Sampling EquipmentAnalysis Type
Acenaphthene (Polynuclear Aromatic Hydrocarbons by GC-MS) 83-32-9 ASTM D 6209
PUF Cartridge: 226-131,
Filter: 225-1808
GC-MS
Acenaphthene (1,2-dihydroacenaphthylene; 1,8-ethylenenapthylene) (Polynuclear Aromatic Hydrocarbons by GC-MS-SIM) NIOSH 5528 GC-MS-SIM
Acenaphthene (Polynuclear Aromatic Hydrocarbons by GC) 83-32-9 NIOSH 5515
Filter in Preloaded Cassette: 225-1713,
Sorbent Tube: 226-30-04,
Filter Cassette and Cyclone Holder: 225-1,
Pumps: 220-5000TC
GC-FID
Acenaphthene (Polynuclear Aromatic Hydrocarbons by HPLC) 83-32-9 NIOSH 5506
Filter in Preloaded Cassette: 225-1713,
Sorbent Tube: 226-30-04,
Filter Cassette and Cyclone Holder: 225-1,
Pumps: 220-5000TC
HPLC-UV
Acenaphthylene (Polynuclear Aromatic Hydrocarbons by GC) 208-96-8 NIOSH 5515
Filter in Preloaded Cassette: 225-1713,
Sorbent Tube: 226-30-04,
Filter Cassette and Cyclone Holder: 225-1,
Pumps: 220-5000TC
GC-FID
Acenaphthylene (Polynuclear Aromatic Hydrocarbons by GC-MS) 208-96-8 ASTM D 6209
PUF Cartridge: 226-131,
Filter: 225-1808
GC-MS
Acenaphthylene (Polynuclear Aromatic Hydrocarbons by HPLC) 208-96-8 NIOSH 5506
Filter in Preloaded Cassette: 225-1713,
Sorbent Tube: 226-30-04,
Filter Cassette and Cyclone Holder: 225-1,
Pumps: 220-5000TC
HPLC-UV
Acetaldehyde 75-07-0 NIOSH 3507
Impinger: 225-36-2,
Impinger Trap: 225-22,
Pumps: 220-1000TC
HPLC
Acetaldehyde 75-07-0 NIOSH 2538
Sorbent Tube: 226-27,
Pumps: 220-1000TC
GC-FID
Acetaldehyde 75-07-0 OSHA 68
Sorbent Tube: 226-27,
Pumps: 220-1000TC
GC-NPD
Acetaldehyde 75-07-0 ASTM D 5197
Sorbent Tube: 226-120 , 226-119,
Pumps: 220-5000TC
HPLC-UV
Acetaldehyde (Aldehydes, Screening) 75-07-0 NIOSH 2539
Sorbent Tube: 226-118,
Pumps: 220-1000TC
GC-FID & GC-MS
Acetaldehyde (see online Passive Sampling Guide) 75-07-0
Detector Tube, Color: 810-91D , 810-152D , 810-151D
Acetamide 60-35-3 OSHA PV2084
Sorbent Tube: 226-10,
Pumps: 220-1000TC
GC-NPD
Acetates (screening) NIOSH 2549
Sorbent Tube: 226-330,
Pumps: 220-1000TC
GC-MS
Acetic acid 64-19-7 OSHA PV2119
Sorbent Tube: 226-01,
Pumps: 220-1000TC
IC or GC-FID
Acetic acid 64-19-7 NIOSH 1603
Sorbent Tube: 226-01,
Pumps: 220-1000TC
GC-FID
Acetic acid (see online Passive Sampling Guide) 64-19-7
Passive Sampler: 575-001
Acetic acid (see online Passive Sampling Guide) 64-19-7
Acetic anhydride 108-24-7 OSHA 102
Coated Filter in Preloaded Cassette: 225-9010,
Filter Cassette and Cyclone Holder: 225-1,
Pumps: 220-5000TC
GC-NPD
Page