Search Results for: ‘First Letter A’

Search Results for: ‘First Letter A’

ChemicalCAS No.Method No.Sampling EquipmentAnalysis Type
Aniline (Amines, Aromatic) 62-53-3 NIOSH 2002
Sorbent Tube: 226-10,
Pumps: 220-1000TC
GC-FID or GC-NSD
Anisidine 29191-52-4 NIOSH 2514
Sorbent Tube: 226-30-05,
Pumps: 220-5000TC
HPLC-UV
Anthophyllite fibers (see asbestos fibers) 77536-67-5 NIOSH 7400 PCM
Anthracene 120-12-7 OSHA 58
Filter: 225-7,
Filter Cassette: 225-2LF,
Filter Cassette and Cyclone Holder: 225-1,
Pumps: 220-5000TC
GR & HPLC-FD, or GR & HPLC-UV
Anthracene (Polynuclear Aromatic Hydrocarbons by GC-MS) 120-12-7 ASTM D 6209
PUF Cartridge: 226-131,
Filter: 225-1808
GC-MS
Anthracene (Polynuclear Aromatic Hydrocarbons by GC) 120-12-7 NIOSH 5515
Filter in Preloaded Cassette: 225-1713,
Sorbent Tube: 226-30-04,
Filter Cassette and Cyclone Holder: 225-1,
Pumps: 220-5000TC
GC-FID
Anthracene (Polynuclear Aromatic Hydrocarbons by HPLC) 120-12-7 NIOSH 5506
Filter in Preloaded Cassette: 225-1713,
Sorbent Tube: 226-30-04,
Filter Cassette and Cyclone Holder: 225-1,
Pumps: 220-5000TC
HPLC-UV
Antimony & compounds (as Sb) 7440-36-0 OSHA ID 121
Filter in Preloaded Cassette: 225-3-01,
Filter Cassette and Cyclone Holder: 225-1,
Pumps: 220-5000TC
AA or AES
Antimony & compounds (as Sb) 7440-36-0 OSHA ID 125G
Filter in Preloaded Cassette: 225-3-01 , 225-3100,
Filter Cassette and Cyclone Holder: 225-1,
Pumps: 220-5000TC
ICP-AES
Antimony (Elements by Cellulosic Internal Capsule Sampler) 7440-36-0 NIOSH 7306
Solu-CAP: 225-8517,
Filter Cassette and Cyclone Holder: 225-1,
Pumps: 220-5000TC
ICP-AES
Antimony (Elements by ICP Aqua Regia Ashing) 7440-36-0 NIOSH 7301
Filter in Preloaded Cassette: 225-3-01 , 225-803,
Filter Cassette and Cyclone Holder: 225-1,
Pumps: 220-5000TC
ICP-AES
Antimony (Elements by ICP HNO3 Digestion) 7440-36-0 NIOSH 7303
Filter in Preloaded Cassette: 225-3-01,
Filter Cassette and Cyclone Holder: 225-1,
Pumps: 220-5000TC
ICP-AES
Antimony (Elements by ICP HNO3/HClO4 Ashing) 7440-36-0 NIOSH 7300
Filter in Preloaded Cassette: 225-3-01,
Filter Cassette and Cyclone Holder: 225-1,
Pumps: 220-5000TC
ICP-AES
Antimony (ICP Analysis of Metal/metalloid Particulates from Solder Operations) 7440-36-0 OSHA ID 206
Filter in Preloaded Cassette: 225-3-01,
Filter Cassette and Cyclone Holder: 225-1,
Pumps: 220-5000TC
ICP-AES
Apron 57837-19-1 OSHA PV2102
Filter in Preloaded Cassette: 225-709,
Filter Cassette and Cyclone Holder: 225-1,
Pumps: 220-5000TC
HPLC-UV
Aroclor 15972-60-8 NIOSH 5602
Sorbent Tube: 226-58,
Pumps: 220-5000TC
GC-ECD
Aroclor 15972-60-8 ASTM D 4861
PUF Cartridge: 226-92,
Pumps: 220-5000TC
GC-ECD
Aroclor 1242 53469-21-9 ASTM D 4861
PUF Cartridge: 226-92,
Pumps: 220-5000TC
GC-ECD
Aroclor 1242 (42% Cl) (see polychlorobiphenyls) 53469-21-9 NIOSH 5503
Filter: 225-16,
Filter Cassette: 225-32,
Sorbent Tube: 226-39,
Pumps: 220-1000TC
GC-ECD
Aroclor 1254 53469-21-9 ASTM D 4861
PUF Cartridge: 226-92,
Pumps: 220-5000TC
GC-ECD
Page