Search Results for: ‘First Letter B’
Search Results for: ‘First Letter B’
Chemical | CAS No. | Method No. | Sampling Equipment | Analysis Type |
---|---|---|---|---|
Benzotrifluoride (trifluoromethyl benzene, OXSOL 2000) (see online Passive Sampling Guide) | 98-08-8 | GC-FID | ||
Benzoyl peroxide | 94-36-0 | NIOSH 5009 | Filter in Preloaded Cassette: 225-3-01, Filter Cassette and Cyclone Holder: 225-1, Pumps: 220-5000TC | HPLC-UV |
Benzyl acetate | 140-11-4 | OSHA PV2124 | Sorbent Tube: 226-73, Pumps: 220-1000TC | GC-FID |
Benzyl acetate (see online Passive Sampling Guide) | 140-11-4 | Passive Sampler: 575-001 | ||
Benzyl alcohol | 100-51-6 | OSHA PV2009 | Sorbent Tube: 226-95, Pumps: 220-1000TC | GC-FID |
Benzyl chloride | 100-44-7 | ASTM D 5466 | GC-MS | |
Benzyl chloride (hydrocarbons, halogenated) | 100-44-7 | NIOSH 1003 | Sorbent Tube: 226-01, Pumps: 220-1000TC | GC-FID |
Benzyl chloride (see online Passive Sampling Guide) | 100-44-7 | Passive Sampler: 575-001 | ||
Beryllium & compounds | 7440-41-7 | OSHA ID 125G | Filter Cassette and Cyclone Holder: 225-1, Pumps: 220-5000TC | ICP-AES |
Beryllium & compounds (as Be) | 7440-41-7 | OSHA 1023 | Filter: 225-5, Filter Cassette: 225-2LF, Smear Tab: 225-24, Pumps: 220-5000TC | ICP-AES |
Beryllium & compounds (as Be) | 7440-41-7 | NIOSH 7102 | Filter in Preloaded Cassette: 225-3-01, Filter Cassette and Cyclone Holder: 225-1, Pumps: 220-5000TC | AA-GF |
Beryllium (Elements by Cellulosic Internal Capsule Sampler) | 7440-41-7 | NIOSH 7306 | Solu-CAP: 225-8517, Filter Cassette and Cyclone Holder: 225-1, Pumps: 220-5000TC | ICP-AES |
Beryllium (Elements by ICP Aqua Regia Ashing) | 7440-41-7 | NIOSH 7301 | Filter Cassette and Cyclone Holder: 225-1, Pumps: 220-5000TC | ICP-AES |
Beryllium (Elements by ICP HNO3 Digestion) | 7440-41-7 | NIOSH 7303 | Filter in Preloaded Cassette: 225-3-01, Filter Cassette and Cyclone Holder: 225-1, Pumps: 220-5000TC | ICP-AES |
Beryllium (Elements by ICP HNO3/HClO4 Ashing) | 7440-41-7 | NIOSH 7300 | Filter Cassette and Cyclone Holder: 225-1, Pumps: 220-5000TC | ICP-AES |
Beryllium (Elements on Wipes) | 7440-41-7 | NIOSH 9102 | wipe: 225-2414, Template: 225-2415 | ICP-AES |
Beryllium (ICP analysis of metal/metalloid particulates from solder operations) | 7440-41-7 | OSHA ID 206 | Filter in Preloaded Cassette: 225-3-01, Filter Cassette and Cyclone Holder: 225-1, Pumps: 220-5000TC | ICP-AES |
Beryllium (in air by portable fluorometry) | 7440-41-7 | NIOSH 7704 | Filter Cassette and Cyclone Holder: 225-1, Pumps: 220-5000TC | P FLUOR UV/VIS |
BHC (alpha-, beta-, gamma-) | 58-89-9 | ASTM D 4861 | PUF Cartridge: 226-92, Pumps: 220-5000TC | GC-ECD |
Bioaerosol sampling | NIOSH 0800 | Bioaerosol Impactor: 225-9611, Pumps: 228-9530 | varies |
Validate your login