Search Results for: ‘First Letter D’

Search Results for: ‘First Letter D’

ChemicalCAS No.Method No.Sampling EquipmentAnalysis Type
N,N-Dimethylformamide 68-12-2 NIOSH 2004
Sorbent Tube: 226-10,
Pumps: 220-1000TC
GC-FID
N,N-Dimethylformamide 68-12-2 OSHA 66
Sorbent Tube: 226-01,
Pumps: 220-1000TC
GC-NPD
N,N-Dimethylformamide (see online Passive Sampling Guide) 68-12-2
Passive Sampler: 575-002
1,1-Dimethylhydrazine 57-14-7 NIOSH 3515
Impinger: 225-36-2,
Impinger Trap: 225-22,
Pumps: 220-5000TC
VAS
Dimethyltin dichloride 753-73-1 NIOSH 5526
Sorbent Tube: 226-30-16,
Pumps: 220-5000TC
GC-FPD
Dinitrotoluene (DNT) 25321-14-6 OSHA 44
Sorbent Tube: 226-56,
Pumps: 220-5000TC
GC-TEA-EAP
n-Dioctyl phthalate (DNOP) 117-84-0 OSHA 104
Sorbent Tube: 226-56,
Pumps: 220-5000TC
GC-FID
Dioxane (diethylene dioxide) 123-91-1 NIOSH 1602
Sorbent Tube: 226-01,
Pumps: 220-1000TC
GC-FID
Dioxane (diethylene dioxide) (see online Passive Sampling Guide) 123-91-1
Passive Sampler: 575-002
Diphenyl (Biphenyl) 92-52-4 NIOSH 2530
Sorbent Tube: 226-35-01,
Pumps: 220-1000TC
GC-FID
Diphenyl ether 92-52-4 OSHA PV2022
Sorbent Tube: 226-95,
Pumps: 220-1000TC
GC-FID
Diphenylamine 122-39-4 OSHA 78
Coated Filter in Preloaded Cassette: 225-9004,
Filter Cassette and Cyclone Holder: 225-1,
Pumps: 220-5000TC
HPLC-UV
Diphenylmethane-4,4'-diisocyanate (4,4-methylene bisphenyl isocyanate) (isocyanates) 101-68-8 NIOSH 5521
Impinger: 225-36-1,
Impinger Trap: 225-22,
Pumps: 220-5000TC
HPLC-ELCHM & HPLC-UV
Dipropyl disulfide 629-19-6 OSHA PV2086
Sorbent Tube: 226-110,
Pumps: 220-1000TC
GC-FPD
Dipropyl ketone (4-heptanone) (see online Passive Sampling Guide) 123-19-3
Passive Sampler: 575-002
Dipropylene glycol methyl ether 34590-94-8 OSHA 101
Sorbent Tube: 226-01,
Pumps: 220-1000TC
GC-FID
Dipropylene glycol methyl ether (glycol ethers) 34590-94-8 NIOSH 2554
Sorbent Tube: 226-81A,
Pumps: 220-1000TC
GC-FID
Dipropylene glycol methyl ether (see online Passive Sampling Guide) 34590-94-8
Passive Sampler: 575-002
Dipropylene glycol monomethyl ether (glycol ethers) 34590-94-8 NIOSH 2554
Sorbent Tube: 226-81A,
Pumps: 220-1000TC
GC-FID
Direct black 38 (dyes, benzidine) 1937-37-7 NIOSH 5013
Filter: 225-17P,
Filter Cassette: 225-3LF,
Filter Cassette and Cyclone Holder: 225-1,
Pumps: 220-5000TC
HPLC
Page