SKC OSHA/NIOSH/ASTM Sampling Guide for Oil mist (mineral)

Chemical Hazard

Oil mist (mineral)

CAS. No.

8012-95-1

Sampling Methodology

NIOSH 5026


Sampling Parameters

Agency Standards (ppm)

Volume

Rate

Time

TWA 5 mg/m3

480 L

1000 ml/min

8 hrs

C/STEL 10 mg/m3

30 L

2000 ml/min

15 hrs

Analytical Method

IR


SKC Sampling Equipment

Preloaded Filter Cassette:225-3-01 or

Preloaded Filter Cassette:225-802 

Filter Cassette and Cyclone Holder:225-1 

Air Sampling Pump:220-5000TC 


Footnotes

Both filters give identical results

This SKC Air Sampling guide is a reference only to assist users in finding the method, sampling equipment, and sampling media for a specific compound. This publication is intended for general information only and should not be used as a substitute for reviewing applicable government regulations, equipment operating instructions, or legal standards. Users must consult the appropriate sampling method for the compound of interest before sampling. The sampling parameters shown here are suggestions based on the ranges or volume, flow, and time specified in the methods. It is the responsibility of the analyst performing the sampling and analysis steps to adjust the parameters so that the required detection limits can be obtained. The information contained in this document should not be construed as legal advice or opinion nor as a final authority on legal or regulatory procedures.