SKC OSHA/NIOSH/ASTM Sampling Guide for Zinc (Elements by ICP HNO3/HClO4 Ashing)
Chemical Hazard
Zinc (Elements by ICP HNO3/HClO4 Ashing)
CAS. No.
7440-66-6
Sampling Methodology
Sampling Parameters
Agency Standards (ppm) |
Volume |
Rate |
Time |
---|---|---|---|
TWA 5 mg/m3 (ZnO) |
5-200 L |
1000-4000 ml/min |
varies hrs |
C/STEL 10 mg/m3 (ZnO) |
5-200 L |
1000-4000 ml/min |
varies hrs |
Analytical Method
ICP-AES
SKC Sampling Equipment
Preloaded Filter Cassette:225-3-01 or
Preloaded Filter Cassette:225-8408
Filter Cassette and Cyclone Holder:225-1
Air Sampling Pump:220-5000TC
Limit of Detection
0.310 µg/filter
This SKC Air Sampling guide is a reference only to assist users in finding the method, sampling equipment, and sampling media for a specific compound. This publication is intended for general information only and should not be used as a substitute for reviewing applicable government regulations, equipment operating instructions, or legal standards. Users must consult the appropriate sampling method for the compound of interest before sampling. The sampling parameters shown here are suggestions based on the ranges or volume, flow, and time specified in the methods. It is the responsibility of the analyst performing the sampling and analysis steps to adjust the parameters so that the required detection limits can be obtained. The information contained in this document should not be construed as legal advice or opinion nor as a final authority on legal or regulatory procedures.