AirChek Essential Pump

Part Number:

220-3000

- +
Overview

AirChek® Essential Pump, includes Li-Ion battery pack and screwdriver set. Requires cradle and power supply. AirChek Essential pumps contain Li-Ion batteries and are subject to special shipping regulations. AirChek Essential requires ¼-inch ID tubing.

At a Glance

The popular AirChek® Essential Sampling Pump delivers the core performance industrial hygiene and other OEHS professionals rely on, with simple touch keypad operation, long run times, rugged durability, and intrinsic safety. It is part of the AirChek Touch Series Sampling Pumps, designed for accurate, dependable sampling with the highest level of ease and the features you need.


 Key Features

  • Flows from 5 to 5000 ml/min
  • 5 to 500 ml/min with low flow holder accessory
  • Multiple-tube sampling with low flow accessories
  • High back pressure compensation up to 50 inches water at 2 L/min
  • Li-Ion battery supporting 40+ hours of operation
  • Automatic flow correction for changes in temperature and atmospheric pressure
  • Bright running and status LEDs for quick visual confirmation, even at a distance
  • Flow fault with auto-restart
  • Elapsed time display
  • Easy touch keypad control
  • Rugged anti-static, no-slip case
  • Worker-friendly: ultra-quiet, small, and lightweight
  • Standard Cradle is chainable up to 5 cradles
  • Lite Cradle is the economical choice
  • Screen lock-out feature and protective cover


Why AirChek Essential

AirChek Essential gives you dependable performance in a simple, economical package. It offers long battery life, high back pressure capability for demanding applications, bright status indicators, intuitive touch controls, and intrinsic safety. Whether used alone or as part of the AirChek Touch Series Sampling Pumps, it delivers the essential functions required for accurate personal or area air sampling—high value at a low price.


 AirChek Essential Kit Options

SKC offers AirChek Essential pumps as follows:

  • Pump only
  • Starter kit (charger, tubing/collar clip/cable tie)
  • Single kits with high flow accessories or both high and low flow accessories
  • 3-pack kits with both high and low flow accessories
  • 5-pack basic kit (no sampling accessories included)
  • 5-pack kits with high flow accessories or both high and low flow accessories

AirChek Touch Series Pump Selection Guide

FeaturesAirChek EssentialAirChek Essential+AirChek TOUCHAirChek Connect
Intrinsically SafeYesYesYesYes
OperationTouch keypadTouch screenColor touch screenTouch screen
ProgrammableNoNoYesYes
PC Compatible - Download HistoryNoNoYesYes
Bluetooth® Connection with PC and MobileNoNoNoYes
SmartWave Mobile AppNoNoNoYes
Compensates for Changes in Temperature and Atmospheric PressureYesYesYesYes
Flow Fault/Auto-restartYesYesYesYes
CalChek® Automatic Flow Rate Verification/Calibration FeatureNoNoYesNo
 

Need help choosing?

Contact us and our team will help match the right AirChek Essential configuration to your sampling requirements.

Attributes
Flow Rate5 to 5000 ml/min
Touch Screen OperationYes
Battery Type (Power)Li-ion
Approx. Run Time40 + Hours at 2 L/min
ConnectivityNo
PC CompatibleNo
ProgrammableNo
Compensates for Changes in Atmospheric PressureYes
Compensates for Changes in TemperatureYes
Constant FlowYes
Constant Pressure ModeNo
Automatic Flow Rate VerificationNo
Intrinsic SafetyYes
CE MarkedYes
UKCA MarkedYes
 

Performance Profile

Pump TypeType P for personal sampling of airborne particles (ISO 13137:2022 compliant)
Nominal Flow RangeConstant flow from 1000 to 5000 ml/min
(5 to 500 ml/min requires low flow holder)
Pressure Drop Capability- 5000 ml/min @ 20 in. water (0–5 kPa)
- 4000 ml/min @ 30 in. water (0–7.5 kPa)
- 3000 ml/min @ 40 in. water (0–10 kPa)
- 2000 ml/min @ 50 in. water (0–12.5 kPa)
- 1000 ml/min @ 60 in. water (0–15 kPa)
Flow Control SystemIsothermal – corrects for back pressure, temperature, and atmospheric pressure
Flow Fault / Auto-RestartStops after 3–10 sec restricted flow, flashes red LEDs, shows fault icon; auto-restarts up to 5x within 5 min, or ends run if fault persists
Power SourceRechargeable Li-Ion (7.2 V, 3.3 Ah, 24 Wh) or AC via cradle
Operating Time- 8+ hrs @ 2000 ml/min, 16 in. water (4 kPa)
- 8+ hrs @ 5000 ml/min, 20 in. water (5 kPa)
- 40+ hrs @ 2000 ml/min*
- 15+ hrs @ 5000 ml/min*
- Indefinite w/ cradle
Charging MethodLite Charging Cradle (Cat. No. 220-850) + Power Supply (Cat. No. 220-600)
Multi-unit setup with Cat. No. 220-851 splitter and supply
Charging TimeApprox. 3 hours (depending on battery and discharge level)
Accuracy- Flow: ±5% of set-point
- Pressure: ±0.3 in Hg
- Temp: ±1.0 °C
- Time: ±0.002%
Temperature Range- Operating: 32–104 °F (0–40 °C)
- Charging: 32–113 °F (0–45 °C)
- Storage: -4–113 °F (-20–45 °C)
Humidity Range≤ 95% RH, non-condensing (operating & storage)
Altitude CompensationCorrects for temperature (32–104 °F) and pressure up to 15,000 ft (4572 m) above and down to 4500 ft (1372 m) below sea level
DisplayB&W display with elapsed sampling time
User InterfaceCapacitive touch screen with locking option
Status LEDsBlinking green = running
Blinking red = fault
Sound LevelAvg. 51.7 dB at 3 ft (1 m) with 37-mm, 0.8-µm MCE filter
Tubing¼-inch ID tubing
Dimensions4.1 x 3.7 x 2.8 in (10.4 x 9.4 x 7.1 cm)
Weight19.4 oz (approx. 550 g)

Certifications / Markings

- Intrinsic safety (SKC Cat. No. 220-3000 operated
with SKC Battery Pack P75718 or P75718A) Class I, Groups
A, B, C, D; Class II, Groups E, F, G; Class III, T4;
Class I, Zone 0, AExia IIC T4 Ga; Exia IIC T4 Ga;
-20°C ≤ Ta ≤ 45°C; Ex II 1G; Exia IIC T4 Ga; IECEx
UL 19.0100, DEMKO 19ATEX 2288; UL22UKEX2351, CE 0539; UKCA 0843
- Designed to meet ISO 13137:2022
- RoHS Compliant
Case MaterialPolycarbonate with rubberized anti-static overmolding
Ingress ProtectionIP6x (dust-tight enclosure)
FeaturesOn-screen battery status, ergonomic design, secure clip, cradle charging, ultra-quiet operation
Media CompatibilitySorbent tubes, filters, size-selective particulate samplers, impingers
Warranty- Pump: 1-year limited
- Battery: 2-year limited (on pumps purchased on or after Feb 13, 2025)

*Tested with 37-mm, 0.8-µm MCE filter on new pump and battery – actual performance may vary.