UMEx 300 Passive Samplers, for Ammonia

Please allow your location to be read or register an account with SKC Inc. to view pricing
Part Number: 500-300

UMEx 300 Passive Samplers, for Ammonia Overview

UMEx 300 Passive Sampler, for Ammonia, with validated concentration range of 0.1 to 100 ppm, pk/10
Limited shelf-life; storage at ≤ 39.2 F (4 C) required.
UMEx passive samplers are designed for single use only. Do NOT reuse UMEx samplers.

Sample workplace ammonia accurately and reliably with SKC UMEx 300 Passive Samplers. It's as easy as clip, sample, ship!

Applications/Industries
Ammonia is one of the most commonly produced industrial chemicals in the United States. Workers can be exposed to ammonia in the following industries:

  • Agricultural (fertilizers)
  • Janitorial services (cleaners)
  • Food and beverage (refrigeration and fermentation)
  • Remediation
  • Fuel
  • Manufacturing
    • Plastics
    • Explosives
    • Pesticides
    • Textiles
    • Dyes

 

Performance Profile

Sampling Rate 39.92 ml/min with a relative standard
Validated Concentration Range 0.1 to 100 ppm
Analysis Method Solvent extraction and ion chromatography with conductivity detection for the ammonium ion or visible absorption spectrometry
Lower Detection Limits 15 min: 2.4 ppm
8 hrs: 0.075 ppm
24 hrs: 0.025 ppm
Shelf-life 9 mos from date of manufacture at < 39.2 F (4 C)
Storage

Before use: < 39.2 F (4 C)

After use: Ambient temperature [72 F (22 C)] or at < 39.2 F (4 C) and analyze within 3 week

Accuracy ± 23.4%
Temperature Effects No effect on sampling rate from 22 to 40 C
Humidity Effects No effect from 20 to 80% relative humidity (RH)
Wind Velocity Effects No effect from 5 to 100 cm/sec
Interferences None identified
Dimensions 3.4 x 1.1 x 0.35 in (8.6 x 2.8 x 0.89 cm)
Weight 0.38 oz (10.9 gm)
Slide Cover Pink

 

 

  • Passive Sampler Use : Ammonia
  • Passive Sampler Sorbent : Treated Tape
  • Validation Level : Full

The SKC UMEx 300 Passive Sampler accurately and reliably samples workplace exposure to ammonia. With its 39.92 ml/min sampling rate, the sensitive UMEx 300 detects ammonia to 2.4 ppm for a 15-minute sample, 0.075 ppm for an eight-hour sample, and 0.025 ppm for a 24-hour sample. Each sampler contains a length of sulfuric acid-treated tape. Analysis is by ion chromatography (IC) with conductivity detection for the ammonium ion or visible absorption spectrometry.

 

So easy to use

Clip the 500-300 onto a worker

Clip

Open the cover to sample with the 500-300

Sample

ship the 500-300 to a lab for analysis

Ship