Universal 44XR Sample Pump
Universal 44XR Sample Pump Overview
Universal 44XR Pump only, with NiMH battery and screwdriver set, charger not included
Flow range: Constant flow 5 to 5000 ml/min
The Universal 44XR personal or area air sampling pump provides a flow range of 5 to 5000 ml/min. This economical turn-on-and-sample air sampling pump offers run times up to 12 hours for sampling particulates and gases/vapors. The pump is ideal for use with sorbent tubes, filter cassettes, size-selective samplers, sample bags, and impingers.
The Universal 44XR air sampling pump is UL Listed for intrinsic safety.
Performance Profile
Operating Range
|
1000 to 5000 ml/min (UL Listed model) |
Weight
|
34 oz (964 gm) |
Dimensions
|
5.1 x 4.7 x 1.9 in (13 x 11.9 x 4.8 cm) |
Compensation Range
|
1000 to 2500 ml/min at 40 inches water back pressure 3000 ml/min at 35 inches water back pressure 4000 ml/min at 20 inches water back pressure 5000 ml/min at 10 inches water back pressure |
Typical Back Pressure
|
See Table 1 below. |
Flow Control
|
Holds constant flow to ± 5% of set-point |
Run Time
|
NiMH Battery: 12 hours minimum at 4000 ml/min and 20 inches water back pressure; dependent on media used. See Table 2. Battery Eliminator: Pump provides extended runs. |
Tubing | 1/4-inch ID tubing, required |
Flow Indicator
|
Built-in rotameter with 250-ml division; scale marked at 1, 2, 3, 4, and 5 L/min |
Power Supply
|
6.0-V plug-in NiMH battery pack, rechargeable, 3.5-Ah capacity A battery eliminator is available (see Ordering Information); use voids the UL Listing for intrinsic safety. |
Intrinsic Safety
|
UL Listed for Class I, Division 1 and 2, Groups A, B, C, D; Class II, Division 1 and 2, Groups E, F, G; and Class III, Temperature Code T3C ATEX-approved models are available. Contact SKC. |
Operating Temperature
|
32 to 104 F (0 to 40 C) |
Storage Temperature
|
-4 to 113 F (-20 to 45 C) |
Charging Temperature
|
50 to 113 F (10 to 45 C) |
Operating Humidity
|
0 to 95% non-condensing |
Multiple-tube Sampling
|
Built-in constant pressure regulator allows user to take up to four simultaneous samples with rates up to 500 ml/min each (total combined flow 1350 ml/min maximum) using the optional adjustable tube holder accessory. |
RFI/EMI Shielding
|
Complies with requirements of EN 55022, FCC Part 15 Class B, EN 50082-1 Frequency range of the radiated susceptibility test was 27 to 1000 MHz CE marked |
Additional Specifications
|
Built-in fluid/particulate trap External see-through filter housing Tamper-resistant control cover Tamper-resistant compensation adjustments Built-in accessory mount Stainless steel belt clip External exhaust port All non-plastic parts made of corrosion-resistant materials RFI and EMI-shielded case |
Additional Features
|
One-year warranty Ultra-quiet operation Pulsation-free flow Impact-resistant case |
Protect sample pump from weather when in use outdoors.
- Pump Flow Rate : 5 to 5000 ml/min
- PC Compatible : No
- Programable : No
- Intrinsic Safety : Yes
- Battery Type (Power) : NiMH
- Approx Run Time : 12
Product Document
44XR Operating Instructions (PDF) 44XR Operating Instructions Spanish (PDF)44XR Operating Instructions German(PDF)44XR Operating Instructions French (PDF)44XR Operating Instructions Portuguese (PDF)44XR Spec. Sheet (PDF) Tech Note: SKC Sample Pump Nickel-Metal Hydride Battery Pack Characteristics and Maintenance (PDF Document)Battery Pack for Universal PCXR Sample Pumps Operating Instructions (PDF)SDS for Nickel Cadmium Battery UL & MSHA models (PDF) SDS for Nickel-metal Hydride Battery (PDF)UL Certificate of Intrinsic SafetyEC Declaration of Conformity (PDF)MSHA Approval Certificate (PDF) EU Declaration of Conformity for Universal 224-44MTX, 224-44PCMTX4, 224-44PCMTX8 (PDF) EU Declaration of Conformity 223-203A,-223A,-227A,-229A,-230A,-239A NiCD/NiMH Battery Chargers (PDF)EU Declaration of Conformity 223-102A,-103A,-105A,-106A,-107A,-109A NiCD/NiMH Battery Chargers (PDF)EU Declaration of Conformity 223-300B,-300C,-305B,-305C,-320B,-320C,-325B,-325C,-330B,-330C AC Adapter (Battery Eliminator) (PDF)