Universal 44XRM Sample Pump, MSHA
Universal 44XRM Sample Pump, MSHA Overview
Universal 44XR MSHA-approved Sample Pump with NiCad battery and screwdriver set, flow range 1 to 3 L/min
Flow range: Constant flow 5 to 3000 ml/min
The Universal 44XR personal or area air sampling pump provides a flow range of 5 to 5000 ml/min. This economical turn-on-and-sample air sampling pump offers run times up to 12 hours for sampling particulates and gases/vapors. The pump is ideal for use with sorbent tubes, filter cassettes, size-selective samplers, sample bags, and impingers.
The Universal 44XR air sampling pump is UL Listed for intrinsic safety.
Performance Profile
Operating Range
|
1000 to 3000 ml/min (5 to 500 ml/min requires adjustable low flow holder) |
Weight
|
34 oz (964 gm) |
Dimensions
|
5.1 x 4.7 x 1.9 in (13 x 11.9 x 4.8 cm) |
Compensation Range
|
1000 ml/min at 40 inches water back pressure 2000 ml/min at 40 inches water back pressure 3000 ml/min at 22 inches water back pressure |
Typical Back Pressure
|
See Table 1 below. |
Flow Control
|
Holds constant flow to ± 5% of set-point |
Run Time
|
8 hrs minimum at 3000 ml/min and 20 inches water back pressure; dependent on media used. |
Tubing | 1/4-inch ID tubing, required |
Flow Indicator
|
Built-in rotameter with 250-ml division; scale marked at 1, 2, 3, 4, and 5 L/min |
Power Supply
|
MSHA approved when used with rechargeable NiCad battery pack, 2.0 Ah capacity, 4.8 V, Cat. No. P22434 only. Recharge battery pack in fresh air only. |
Intrinsic Safety
|
MSHA-approved to 30 CFR, section 18; approval no. 2G-4036-0 Tested for use in methane-air mixtures only |
Operating Temperature
|
32 to 113 F (0 to 45 C) |
Storage Temperature
|
-4 to 113 F (-20 to 45 C) |
Charging Temperature
|
50 to 113 F (10 to 45 C) |
Operating Humidity
|
0 to 95% non-condensing Protect sample pump from weather when in use outdoors. |
Multiple-tube Sampling
|
Built-in constant pressure regulator allows user to take up to four simultaneous tube samples at different flow rates up to 500 ml/min each using optional adjustable tube holder. |
RFI/EMI Shielding
|
Complies with requirements of EN 55022, FCC Part 15 Class B, EN 50082-1; frequency range of the radiated susceptibility test was 27 to 1000 MHz. |
Tubing | Requires 1/4-inch ID tubing |
Protect sample pump from weather when in use outdoors.
- Pump Flow Rate : 5 to 5000 ml/min
- PC Compatible : No
- Programable : No
- Intrinsic Safety : Yes
- Battery Type (Power) : NiMH
- Approx Run Time : 12
Product Document
Universal Sample Pump 224-44XRM Operating Instructions (PDF)
SDS for Nickel Cadmium Battery UL & MSHA models (PDF)
MSHA Approval Certificate (PDF)
EU Declaration of Conformity for Universal 224-44MTX, 224-44PCMTX4, 224-44PCMTX8 (PDF)
EU Declaration of Conformity 223-203A,-223A,-227A,-229A,-230A,-239A NiCD/NiMH Battery Chargers (PDF)
EU Declaration of Conformity 223-102A,-103A,-105A,-106A,-107A,-109A NiCD/NiMH Battery Chargers (PDF)