SKC OSHA / NIOSH Sampling Guide for Ethylene oxide (Qazi-Ketcham)

SKC OSHA / NIOSH Sampling Guide for Ethylene oxide (Qazi-Ketcham)
Chemical Information
Ethylene oxide (Qazi-Ketcham)
75-21-8
GC
 
Sampling Parameters

TWA 1 ppm (0.5ppm action level)
C/STEL 5.0 ppm (15min excursion limit)

10 L

20(50) ml/min

8(3.3) hr

Important Information
NON 14: Union Carbide Corp. South Charleston, WV. 'A New Method for Monitoring Personal Exposure to Ethylene Oxide in the Occupational Environment.'

SKC Sampling Equipment

Pumps:
  1. Pocket Pump TOUCH Pump
    Part Number: 220-1000TC
    $806.00 /EA
    Pocket Pump® TOUCH with Li-Ion battery and screwdriver. Requires charger. Requires 877-94 to use Bluetooth with PC.

This SKC Air Sampling Guide is a reference only to assist users in finding the method, sampling equipment, and sampling media for a specific compound. This publication is intended for general information only and should not be used as a substitute for reviewing applicable government regulations, equipment operating instructions, or legal standards. Users must consult the appropriate sampling method for the compound of interest before sampling. The sampling parameters shown here are suggestions based on the ranges or volume, flow, and time specified in the methods. It is the responsibility of the analyst performing the sampling and analysis steps to adjust the parameters so that the required detection limits can be obtained. The information contained in this document should not be construed as legal advice or opinion nor as a final authority on legal or regulatory procedures.