SKC OSHA / NIOSH Sampling Guide for Sulfuric acid

SKC OSHA / NIOSH Sampling Guide for Sulfuric acid
Chemical Information
Sulfuric acid
7664-93-9
IC
 
Sampling Parameters

TWA 0.2 mg/m3 *
C/STEL

480 L

2000 ml/min

4 hr

Important Information
* ACGIH thoracic TWA
Use PPI for thoracic fraction TWA
see - ACGIH 2009 TLVs® and BEIs® (ACGIH publications, 2009)

SKC Sampling Equipment

Parallel Particle Impactor:
  1. Parallel Particle Impactor (PPI), Aluminum, Thoracic, 2 L/min, Filter and Support Pad Not Included, Blue
    Part Number: 225-381
    $437.00 /EA
    This aluminum Reusable PPI® Sampler features four impactors arranged in parallel for precise thoracic dust sampling at 2 L/min that meets ISO 7708/CEN thoracic criteria. The blue color identifies it as a 2 L/min thoracic model.   Requires substrates, filters, and supports purchased separately.
Filter:
  1. Filter, MCE w/Support Pad, 0.80 µm, 37mm, 100Pk
    Part Number: 225-5
    $59.95 /PK
    MCE Filter, 0.8 µm, 37-mm, support pad included.
Impaction Substrate:
  1. Parallel Particle Impactor (PPI) Impaction Substrates, Pre-Oiled, 200Pk
    Part Number: 225-388
    $136.00 /PK
    These impaction substrate are for use with aluminum Reusable Parallel Particle Impactors (PPI®s), 3/8-inch diameter porous plastic discs, pre-oiled, ready to use, and disposable. Single use; each sample requires four impaction substrate discs.
Support Pads:
  1. Support Pad, Cellulose, 37mm, 100Pk
    Part Number: 225-27
    $18.95 /PK
    Support Pad, cellulose, 37-mm.
Pumps:
  1. AirChek TOUCH Pump
    Part Number: 220-5000TC
    $1,208.00 /EA
    AirChek® TOUCH AirChek Pump with Li-Ion battery pack and screwdriver set. Requires charging cradle and power supply. Connectivity to PC requires 877-93. Low flows from 5 to 500 ml/min require a low flow kit. AirChek TOUCH pumps contain Li-Ion batteries and are subject to special shipping regulations. AirChek TOUCH requires ¼-inch ID tubing.

This SKC Air Sampling Guide is a reference only to assist users in finding the method, sampling equipment, and sampling media for a specific compound. This publication is intended for general information only and should not be used as a substitute for reviewing applicable government regulations, equipment operating instructions, or legal standards. Users must consult the appropriate sampling method for the compound of interest before sampling. The sampling parameters shown here are suggestions based on the ranges or volume, flow, and time specified in the methods. It is the responsibility of the analyst performing the sampling and analysis steps to adjust the parameters so that the required detection limits can be obtained. The information contained in this document should not be construed as legal advice or opinion nor as a final authority on legal or regulatory procedures.