SKC OSHA / NIOSH Sampling Guide for Acrylic acid

SKC OSHA / NIOSH Sampling Guide for Acrylic acid
Chemical Information
Acrylic acid
79-10-7
LC-UV
 
Sampling Parameters

TWA 2 ppm*
C/STEL

20 L

100 ml/min

4 hr

Important Information
*NIOSH exposure limit.

SKC Sampling Equipment

Sorbent Tube:
  1. Sorbent Tube, Anasorb 708, 6 x 70-mm size, 1 section, 100 mg sorbent, 40/60 mesh, 50Pk
    Part Number: 226-30-08
    $332.00 /PK
    Sorbent Tube, Anasorb 708, 6 x 70-mm size, 1 section, 100 mg sorbent, 40/60 mesh.   Tube Ends: Glass Sealed Separators: Glass Wool/Glass Wool   Anasorb 708 is equivalent to Chromosorb® 108

This SKC Air Sampling Guide is a reference only to assist users in finding the method, sampling equipment, and sampling media for a specific compound. This publication is intended for general information only and should not be used as a substitute for reviewing applicable government regulations, equipment operating instructions, or legal standards. Users must consult the appropriate sampling method for the compound of interest before sampling. The sampling parameters shown here are suggestions based on the ranges or volume, flow, and time specified in the methods. It is the responsibility of the analyst performing the sampling and analysis steps to adjust the parameters so that the required detection limits can be obtained. The information contained in this document should not be construed as legal advice or opinion nor as a final authority on legal or regulatory procedures.