SKC OSHA / NIOSH Sampling Guide for Peroxyacetic acid (peracetic acid) & Hydrogen peroxide

SKC OSHA / NIOSH Sampling Guide for Peroxyacetic acid (peracetic acid) & Hydrogen peroxide
Chemical Information
Peroxyacetic acid (peracetic acid) & Hydrogen peroxide
79-21-0 & 7722-84-1
MAS/HPLC-UV
 
Sampling Parameters

TWA
C/STEL


15 L


1000 ml/min *


15 min

Important Information
NON 57: Hecht, G., Hery, M., Hubert, G., and Subra, I., "Simultaneous Sampling of Peroxyacetic Acid and Hydrogen Peroxide in Workplace Atmospheres,"  Ann. Occup. Hyg., Vol. 48, No. 8, 2004, pp. 715-721, doi: 10.1093/annhyg/meh067.

SKC Sampling Equipment

Coated Filter in Preloaded Cassette:
  1. Coated Filter Cassette, Quartz R-100 coated w/Titanium Oxysulfate Hydrate (TiOSO[4]), w/o Support Pad, 25mm, 2-Piece Traditional Style Styrene Cassette, Banded, 10Pk
    Part Number: 225-9030
    $198.00 /PK
    Coated Filters, 2 Quartz (R-100) filters, coated with titanium oxysulfate hydrate (TiOSO[4]), preloaded in a 25-mm 2-piece clear plastic cassette, prebanded. Meets OSHA Method 1019 for Hydrogen Peroxide. Also meets specifications of Non-agency Method 57 for simultaneous, separate sampling of hydrogen peroxide and peracetic acid, when used with Sorbent Tube Cat. No. 225-193-UC or 225-199-UC.
Sorbent Tube:
  1. Sorbent Tube, Silica Gel, treated w/methyl p-tolyl sulfoxide (MTSO), 7 x 110-mm size, 1 section, 800 mg sorbent, 20/40 mesh, 20Pk
    Part Number: 226-193-UC
    $218.00 /PK
    Sorbent Tube, Silica Gel, treated with Methyl p-tolyl sulfoxide (MTSO), 7 x 110-mm size, 1 section, 800 mg sorbent, 20/40 mesh. Requires coated filter Cat. No. 225-9030 for simultaneous, separate sampling of peracetic acid and hydrogen peroxide per Non-agency Method 57 for PAA. Tube Ends: Glass Sealed Separators: Glass Wool/Glass Wool
  2. Sorbent Tube, Silica Gel, treated w/methyl p-tolyl sulfoxide (MTSO), 8 x 110-mm size, 2 sections, 800/200 mg sorbent, 20/40 mesh, 20Pk
    Part Number: 226-199-UC
    $296.00 /PK
    Sorbent Tube, Silica Gel, treated with methyl p-tolyl sulfoxide (MTSO), 8 x 110-mm size, 2 section, 800/200 mg sorbent, 20/40 mesh. Requires coated filter Cat. No. 225-9030 for simultaneous, separate sampling of peracetic acid and hydrogen peroxide per Non-agency Method 57 for PAA. Tube Ends: Glass Sealed Separators: Glass Wool/Glass Fiber Filter/Glass Wool
Pumps:
  1. AirChek TOUCH Pump
    Part Number: 220-5000TC
    $1,208.00 /EA
    AirChek® TOUCH AirChek Pump with Li-Ion battery pack and screwdriver set. Requires charging cradle and power supply. Connectivity to PC requires 877-93. Low flows from 5 to 500 ml/min require a low flow kit. AirChek TOUCH pumps contain Li-Ion batteries and are subject to special shipping regulations. AirChek TOUCH requires ¼-inch ID tubing.

This SKC Air Sampling Guide is a reference only to assist users in finding the method, sampling equipment, and sampling media for a specific compound. This publication is intended for general information only and should not be used as a substitute for reviewing applicable government regulations, equipment operating instructions, or legal standards. Users must consult the appropriate sampling method for the compound of interest before sampling. The sampling parameters shown here are suggestions based on the ranges or volume, flow, and time specified in the methods. It is the responsibility of the analyst performing the sampling and analysis steps to adjust the parameters so that the required detection limits can be obtained. The information contained in this document should not be construed as legal advice or opinion nor as a final authority on legal or regulatory procedures.