SKC OSHA / NIOSH Sampling Guide for Vanadium respirable dust (as V2O5)

SKC OSHA / NIOSH Sampling Guide for Vanadium respirable dust (as V2O5)
Chemical Information
Vanadium respirable dust (as V2O5)
1314-62-1
ICP-AES
Qualitative: 0.57 µg (V)
Quantitative: 1.9 µg (V)
Sampling Parameters

TWA
C/STEL 0.5 mg/m3


varies


varies


varies

SKC Sampling Equipment

Filter in Preloaded Cassette:
  1. Filter Cassette, MCE w/ Support Pad, 0.80 µm, 37mm, 3-Piece, Banded, 50Pk
    Part Number: 225-3-01
    $74.95 /PK
    Preloaded MCE Filter, 0.8 µm, 37-mm, preloaded in 3-piece clear styrene cassette, pre-banded.
Cyclone:
  1. GS-1 Single Inlet Cyclone, 10 mm w/DPM and 37mm Cassette Adapter
    Part Number: 225-105
    $90.00 /EA
    GS-1 Single-inlet Cyclone, 10 mm, conductive plastic construction, 2-L/min flow rate for DPM sampling with a bowl adapter for DPM cassettes and a 37-mm cassette adapter.
Filter Cassette and Cyclone Holder:
  1. Filter Cassette Holder
    Part Number: 225-1
    $33.00 /EA
    Filter Cassette Holder, accommodates two or three-piece 25 or 37-mm cassettes with or without a cyclone, clips to a worker's collar; includes 3 feet of 1/4-inch ID Tygon tubing and 25-mm adapter ring.
Parallel Particle Impactor:
  1. Parallel Particle Impactor (PPI), Disposable, Respirable, 2 L/min, Filter and Support Pad Not Included, Gold
    Part Number: 225-385
    $26.95 /EA
    This plastic Disposable PPI® Sampler features four impactors arranged in parallel for precise respirable dust sampling at 2 L/min that meets ISO 7708/CEN respirable criteria. It is preloaded with four porous plastic disc impaction substrates. Requires a user-loaded 37-mm filter and support purchased separately. The gold color identifies it as a 2 L/min respirable model. Single use.
Filter:
  1. Filter, MCE w/o Support Pad, 0.80 µm, 37mm, 100Pk
    Part Number: 225-1939
    $44.95 /PK
    MCE Filter, 0.8 µm, 37-mm, no support pad included.

This SKC Air Sampling Guide is a reference only to assist users in finding the method, sampling equipment, and sampling media for a specific compound. This publication is intended for general information only and should not be used as a substitute for reviewing applicable government regulations, equipment operating instructions, or legal standards. Users must consult the appropriate sampling method for the compound of interest before sampling. The sampling parameters shown here are suggestions based on the ranges or volume, flow, and time specified in the methods. It is the responsibility of the analyst performing the sampling and analysis steps to adjust the parameters so that the required detection limits can be obtained. The information contained in this document should not be construed as legal advice or opinion nor as a final authority on legal or regulatory procedures.