Universal 44XR Pump
Part Number:
224-44XR
Overview
Universal 44XR Pump only, with NiMH battery and screwdriver set. Requires charger.
Part Number:
224-44XR
Flow Rate | 5 to 5000 ml/min |
---|---|
Touch Screen Operation | No |
Battery Type (Power) | NiMH |
Approx. Run Time | 12+ Hours at 4 L/min |
Connectivity | No |
PC Compatible | No |
Programmable | No |
Compensates for Changes in Atmospheric Pressure | No |
Compensates for Changes in Temperature | No |
Constant Flow | Yes |
Constant Pressure Mode | No |
Automatic Flow Rate Verification | No |
Intrinsic Safety | Yes |
CE Marked | Yes |
UKCA Marked | Yes |
Operating Range | 1000 to 5000 ml/min (UL Listed model) |
Weight | 34 oz (964 gm) |
Dimensions | 5.1 x 4.7 x 1.9 in (13 x 11.9 x 4.8 cm) |
Compensation Range | 1000 to 2500 ml/min at 40 inches water back pressure 3000 ml/min at 35 inches water back pressure 4000 ml/min at 20 inches water back pressure 5000 ml/min at 10 inches water back pressure |
Typical Back Pressure | See Table 1 below. |
Flow Control | Holds constant flow to ± 5% of set-point |
Run Time | NiMH Battery: 12 hours minimum at 4000 ml/min and 20 inches water back pressure; dependent on media used. See Table 2. Battery Eliminator: Pump provides extended runs. |
Tubing | 1/4-inch ID tubing, required |
Flow Indicator | Built-in rotameter with 250-ml division; scale marked at 1, 2, 3, 4, and 5 L/min |
Power Supply | 6.0-V plug-in NiMH battery pack, rechargeable, 3.5-Ah capacity A battery eliminator is available (see Ordering Information); use voids the UL Listing for intrinsic safety. |
Intrinsic Safety | UL Listed for Class I, Division 1 and 2, Groups A, B, C, D; Class II, Division 1 and 2, Groups E, F, G; and Class III, Temperature Code T3C ATEX-approved models are available. Contact SKC. |
Operating Temperature | 32 to 104 F (0 to 40 C) |
Storage Temperature | -4 to 113 F (-20 to 45 C) |
Charging Temperature | 50 to 113 F (10 to 45 C) |
Operating Humidity | 0 to 95% non-condensing |
Multiple-tube Sampling | Built-in constant pressure regulator allows user to take up to four simultaneous samples with rates up to 500 ml/min each (total combined flow 1350 ml/min maximum) using the optional adjustable tube holder accessory. |
RFI/EMI Shielding | Complies with requirements of EN 55022, FCC Part 15 Class B, EN 50082-1 Frequency range of the radiated susceptibility test was 27 to 1000 MHz CE marked |
Additional Specifications | Built-in fluid/particulate trap External see-through filter housing Tamper-resistant control cover Tamper-resistant compensation adjustments Built-in accessory mount Stainless steel belt clip External exhaust port All non-plastic parts made of corrosion-resistant materials RFI and EMI-shielded case |
Additional Features | One-year warranty Ultra-quiet operation Pulsation-free flow Impact-resistant case |
Protect sample pump from weather when in use outdoors.