Universal 44XR Single Pump Kit, with pump, NiMH battery, screwdriver set, 100-240V single charger, filter cassette holder, adjustable tube holder with Type A protective tube cover, exhaust port fitting, and carry case.
The Universal 44XR personal or area air sampling pump provides a flow range of 5 to 5000 ml/min. This economical turn-on-and-sample air sampling pump offers run times up to 12 hours for sampling particulates and gases/vapors. The pump is ideal for use with sorbent tubes, filter cassettes, size-selective samplers, sample bags, and impingers. The Universal 44XR air sampling pump is UL Listed for intrinsic safety.
1000 to 5000 ml/min (UL Listed model) 1000 to 3000 ml/min (MSHA-approved model) (5 to 500 ml/min requires the Cat. No.224-26 Series adjustable tube holder) Requires 1/4-inch ID tubing
Weight
34 oz (964 gm)
Dimensions
5.1 x 4.7 x 1.9 in (13 x 11.9 x 4.8 cm)
Compensation Range
1000 to 2500 ml/min at 40 inches water back pressure 3000 ml/min at 35 inches water back pressure 4000 ml/min at 20 inches water back pressure 5000 ml/min at 10 inches water back pressure
Typical Back Pressure
See Table 1 below.
Flow Control
Holds constant flow to ± 5% of set-point
Run Time
NiMH Battery: 12 hours minimum at 4000 ml/min and 20 inches water back pressure; dependent on media used. See Table 2. Battery Eliminator: Pump provides extended runs.
Tubing
1/4-inch ID tubing, required
Flow Indicator
Built-in rotameter with 250-ml division; scale marked at 1, 2, 3, 4, and 5 L/min
Power Supply
6.0-V plug-in NiMH battery pack, rechargeable, 3.5-Ah capacity A battery eliminator is available (see Ordering Information); use voids the UL Listing for intrinsic safety.
Intrinsic Safety
UL Listed for Class I, Division 1 and 2, Groups A, B, C, D; Class II, Division 1 and 2, Groups E, F, G; and Class III, Temperature Code T3C ATEX-approved models are available. Contact SKC.
Operating Temperature
32 to 104 F (0 to 40 C)
Storage Temperature
-4 to 113 F (-20 to 45 C)
Charging Temperature
50 to 113 F (10 to 45 C)
Operating Humidity
0 to 95% non-condensing
Multiple-tube Sampling
Built-in constant pressure regulator allows user to take up to four simultaneous samples with rates up to 500 ml/min each (total combined flow 1350 ml/min maximum) using the optional adjustable tube holder accessory.
RFI/EMI Shielding
Complies with requirements of EN 55022, FCC Part 15 Class B, EN 50082-1 Frequency range of the radiated susceptibility test was 27 to 1000 MHz CE marked
Additional Specifications
Built-in fluid/particulate trap External see-through filter housing Tamper-resistant control cover Tamper-resistant compensation adjustments Built-in accessory mount Stainless steel belt clip External exhaust port All non-plastic parts made of corrosion-resistant materials RFI and EMI-shielded case
Additional Features
One-year warranty Ultra-quiet operation Pulsation-free flow Impact-resistant case
Protect sample pump from weather when in use outdoors.